An integrated, multiparametric flow cytometry chip using "microfluidic drifting" based three-dimensional hydrodynamic focusing.

In this work, we demonstrate an integrated, single-layer, miniature flow cytometry device that is capable of multi-parametric particle analysis. The device integrates both particle focusing and detection components on-chip, including a "microfluidic drifting" based three-dimensional (3D) hydrodynamic focusing component and a series of optical fibers integrated into the microfluidic architecture to facilitate on-chip detection. With this design, multiple optical signals (i.e., forward scatter, side scatter, and fluorescence) from individual particles can be simultaneously detected. Experimental results indicate that the performance of our flow cytometry chip is comparable to its bulky, expensive desktop counterpart. The integration of on-chip 3D particle focusing with on-chip multi-parametric optical detection in a single-layer, mass-producible microfluidic device presents a major step towards low-cost flow cytometry chips for point-of-care clinical diagnostics.

[1]  Mehmet Toner,et al.  A robust electrical microcytometer with 3-dimensional hydrofocusing. , 2009, Lab on a chip.

[2]  Tzuen-Rong J Tzeng,et al.  Electrokinetic focusing and filtration of cells in a serpentine microchannel. , 2009, Biomicrofluidics.

[3]  Tony Jun Huang,et al.  Hydrodynamically tunable optofluidic cylindrical microlens. , 2007, Lab on a chip.

[4]  Hywel Morgan,et al.  Positional dependence of particles in microfludic impedance cytometry. , 2011, Lab on a chip.

[5]  Ai Qun Liu,et al.  Microfluidic continuous particle/cell separation via electroosmotic-flow-tuned hydrodynamic spreading , 2007 .

[6]  Ai-Qun Liu Preface to special topic: optofluidics. , 2010, Biomicrofluidics.

[7]  Lai Wei,et al.  MCAM-expressing CD4(+) T cells in peripheral blood secrete IL-17A and are significantly elevated in inflammatory autoimmune diseases. , 2011, Journal of autoimmunity.

[8]  M. Vellekoop,et al.  Characterization of a microflow cytometer with an integrated three-dimensional optofluidic lens system. , 2010, Biomicrofluidics.

[9]  Dong-Chul Han,et al.  Plastic microchip flow cytometer based on 2- and 3-dimensional hydrodynamic flow focusing , 2003 .

[10]  Ruey-Jen Yang,et al.  Three-dimensional hydrodynamic focusing in two-layer polydimethylsiloxane (PDMS) microchannels , 2007 .

[11]  Detlef Snakenborg,et al.  Improved bacteria detection by coupling magneto-immunocapture and amperometry at flow-channel microband electrodes. , 2011, Biosensors & bioelectronics.

[12]  Yu-Hwa Lo,et al.  Microfluidic cell sorter with integrated piezoelectric actuator , 2009, Biomedical microdevices.

[13]  D. Di Carlo,et al.  Sheathless inertial cell ordering for extreme throughput flow cytometry. , 2010, Lab on a chip.

[14]  H. Shapiro Practical Flow Cytometry: Shapiro/Flow Cytometry 4e , 2005 .

[15]  M. Vellekoop,et al.  Miniaturized flow cytometer with 3D hydrodynamic particle focusing and integrated optical elements applying silicon photodiodes , 2011 .

[16]  Tony Jun Huang,et al.  Optofluidic tunable microlens by manipulating the liquid meniscus using a flared microfluidic structure. , 2010, Biomicrofluidics.

[17]  T. Huang,et al.  Single-layer planar on-chip flow cytometer using microfluidic drifting based three-dimensional (3D) hydrodynamic focusing. , 2009, Lab on a chip.

[18]  Daniel Ahmed,et al.  A fast microfluidic mixer based on acoustically driven sidewall-trapped microbubbles , 2009 .

[19]  Chun-Ping Jen,et al.  An insulator-based dielectrophoretic microdevice for the simultaneous filtration and focusing of biological cells. , 2011, Biomicrofluidics.

[20]  A. Mastro,et al.  Application of the dual-micropipet technique to the measurement of tumor cell locomotion. , 1999, Experimental cell research.

[21]  Gwo-Bin Lee,et al.  An integrated microfluidic system for isolation, counting, and sorting of hematopoietic stem cells. , 2010, Biomicrofluidics.

[22]  V. Lien,et al.  Demonstration of two-dimensional fluidic lens for integration into microfluidic flow cytometers , 2006 .

[23]  Hsueh-Chia Chang,et al.  An integrated dielectrophoretic chip for continuous bioparticle filtering, focusing, sorting, trapping, and detecting. , 2007, Biomicrofluidics.

[24]  W. El-Deiry,et al.  Tumor necrosis factor–related apoptosis-inducing ligand (TRAIL) and paclitaxel have cooperative in vivo effects against glioblastoma multiforme cells , 2009, Molecular Cancer Therapeutics.

[25]  M. Gijs,et al.  Three-dimensional magnetic focusing of superparamagnetic beads for on-chip agglutination assays. , 2011, Analytical chemistry.

[26]  L. B. Nielsen,et al.  Fiber‐free coupling between bulk laser beams and on‐chip polymer‐based multimode waveguides , 2011, Electrophoresis.

[27]  David W Inglis,et al.  Determining blood cell size using microfluidic hydrodynamics. , 2008, Journal of immunological methods.

[28]  T. Huang,et al.  Continuous particle separation in a microfluidic channel via standing surface acoustic waves (SSAW). , 2009, Lab on a chip.

[29]  Christian H. Reccius,et al.  Leukocyte analysis and differentiation using high speed microfluidic single cell impedance cytometry. , 2009, Lab on a chip.

[30]  Alex Groisman,et al.  High-throughput and high-resolution flow cytometry in molded microfluidic devices. , 2006, Analytical chemistry.

[31]  Jinjie Shi,et al.  Tunable Liquid Gradient Refractive Index (L-GRIN) lens with two degrees of freedom. , 2009, Lab on a chip.

[32]  Daniel Ahmed,et al.  Acoustic tweezers: patterning cells and microparticles using standing surface acoustic waves (SSAW). , 2009, Lab on a chip.

[33]  Chun-Hao Chen,et al.  Microfluidics and photonics for Bio‐System‐on‐a‐Chip: A review of advancements in technology towards a microfluidic flow cytometry chip , 2008, Journal of biophotonics.

[34]  Yu-Hwa Lo,et al.  Review Article: Recent advancements in optofluidic flow cytometer. , 2010, Biomicrofluidics.

[35]  Yu-Hwa Lo,et al.  Two-parameter angular light scatter collection for microfluidic flow cytometry by unique waveguide structures , 2010, Biomedical optics express.

[36]  C. Batt,et al.  Hydrodynamic optical alignment for microflow cytometry. , 2011, Lab on a chip.

[37]  Daniel Ahmed,et al.  A millisecond micromixer via single-bubble-based acoustic streaming. , 2009, Lab on a chip.

[38]  Gwo-Bin Lee,et al.  Micromachined flow cytometers with embedded etched optic fibers for optical detection , 2003 .

[39]  David Newport,et al.  An optical counting technique with vertical hydrodynamic focusing for biological cells. , 2010, Biomicrofluidics.

[40]  I-Kao Chiang,et al.  Three-dimensional continuous particle focusing in a microfluidic channel via standing surface acoustic waves (SSAW). , 2011, Lab on a chip.

[41]  John T McDevitt,et al.  A Microchip CD4 Counting Method for HIV Monitoring in Resource-Poor Settings , 2005, PLoS medicine.

[42]  Tza-Huei Wang,et al.  Single-molecule analysis enables free solution hydrodynamic separation using yoctomole levels of DNA. , 2011, Journal of the American Chemical Society.

[43]  Sungyoung Choi,et al.  Three-dimensional hydrodynamic focusing with a single sheath flow in a single-layer microfluidic device. , 2009, Lab on a chip.

[44]  Three-dimensional cellular focusing utilizing a combination of insulator-based and metallic dielectrophoresis. , 2011, Biomicrofluidics.

[45]  P. Athanassiadou,et al.  An improved flow cytometric assay for detection and discrimination between malignant cells and atypical mesothelial cells, in serous cavity effusions , 2011, Cytometry. Part B, Clinical cytometry.

[46]  Cheng Dong,et al.  In Vitro Characterization and Micromechanics of Tumor Cell Chemotactic Protrusion, Locomotion, and Extravasation , 2002, Annals of Biomedical Engineering.

[47]  C. Wittwer,et al.  Flow cytometry: principles and clinical applications in hematology. , 2000, Clinical chemistry.

[48]  Alex Groisman,et al.  Two-dimensional hydrodynamic focusing in a simple microfluidic device , 2005 .

[49]  Daniel Ahmed,et al.  Focusing microparticles in a microfluidic channel with standing surface acoustic waves (SSAW). , 2008, Lab on a chip.

[50]  J. Moss,et al.  Phenotypic characterization of disseminated cells with TSC2 loss of heterozygosity in patients with lymphangioleiomyomatosis. , 2010, American journal of respiratory and critical care medicine.

[51]  V. Lien,et al.  High-sensitivity cytometric detection using fluidic-photonic integrated circuits with array waveguides , 2005, IEEE Journal of Selected Topics in Quantum Electronics.

[52]  Jeffrey S Erickson,et al.  Optofluidic characterization of marine algae using a microflow cytometer. , 2011, Biomicrofluidics.

[53]  Seung‐Man Yang,et al.  Liquid–liquid fluorescent waveguides using microfluidic-drifting-induced hydrodynamic focusing , 2011 .

[54]  A. Bhagat,et al.  Continuous particle separation in spiral microchannels using Dean flows and differential migration. , 2008, Lab on a chip.

[55]  J. Sturm,et al.  Microfluidic device for label-free measurement of platelet activation. , 2008, Lab on a chip.

[56]  Alex Terray,et al.  "Off-the-shelf" 3-D microfluidic nozzle. , 2010, Lab on a chip.

[57]  Mehmet Toner,et al.  Particle focusing in staged inertial microfluidic devices for flow cytometry. , 2010, Analytical chemistry.

[58]  Daniel A Fletcher,et al.  Analyzing cell mechanics in hematologic diseases with microfluidic biophysical flow cytometry. , 2008, Lab on a chip.

[59]  Tony Jun Huang,et al.  "Microfluidic drifting"--implementing three-dimensional hydrodynamic focusing with a single-layer planar microfluidic device. , 2007, Lab on a chip.

[60]  S. Eden,et al.  Analysis of apoptosis in FUCCI HeLa cells , 2011, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[61]  W. El-Deiry,et al.  Visualization and enrichment of live putative cancer stem cell populations following p53 inactivation or Bax deletion using non-toxic fluorescent dyes , 2009, Cancer biology & therapy.

[62]  D. Ehrlich,et al.  Vertical hydrodynamic focusing in glass microchannels. , 2009, Biomicrofluidics.

[63]  J Loureiro,et al.  Magnetoresistive chip cytometer. , 2011, Lab on a chip.

[64]  A. Bhagat,et al.  Inertial microfluidics for continuous particle separation in spiral microchannels. , 2009, Lab on a chip.

[65]  Mehmet Toner,et al.  A microfluidic device for practical label-free CD4(+) T cell counting of HIV-infected subjects. , 2007, Lab on a chip.

[66]  Enrico Gratton,et al.  Bimetallic nanopetals for thousand-fold fluorescence enhancements , 2010 .

[67]  C. Harnett,et al.  Three-dimensional hydrodynamic focusing in a microfluidic Coulter counter. , 2008, The Review of scientific instruments.

[68]  Lisa R. Hilliard,et al.  Multi-wavelength microflow cytometer using groove-generated sheath flow. , 2009, Lab on a chip.

[69]  Howard M. Shapiro,et al.  Practical Flow Cytometry , 1985 .