Phase Resetting in One-Dimensional Model of the Sinoatrial Node

In this paper, we use a one-dimensional model of the rabbit sinoatrial node (SAN), and we investigate the response of the model to hyperpolarizing and depolarizing stimulus. Depending on the stimulus timing, either a delay or an advance in the occurrence of next action potential is produced. This resetting behavior of the model is quantified in terms of phase transition curves (PTCs) for short electrical current pulses of varying amplitude which span the whole period. The main focus of this paper is to compare the dynamic properties of the spatially extended system and the single cell model. The detailed analysis of the results provides new insights in the understanding of the transition from the theoretical single cell models to the spatially extended systems.

[1]  A. Winfree The geometry of biological time , 1991 .

[2]  M R Guevara,et al.  Phase resetting in a model of sinoatrial nodal membrane: ionic and topological aspects. , 1990, The American journal of physiology.

[3]  P. Hunter,et al.  One‐Dimensional Rabbit Sinoatrial Node Models: , 2003, Journal of cardiovascular electrophysiology.

[4]  Michael C. Mackey,et al.  From Clocks to Chaos , 1988 .

[5]  J Jalife,et al.  A Mathematical Model of the Effects of Acetylcholine Pulses on Sinoatrial Pacemaker Activity , 1984, Circulation research.

[6]  M R Boyett,et al.  Gradient Model Versus Mosaic Model of the Sinoatrial Node , 2001, Circulation.

[7]  A. Winfree Biological rhythms and the behavior of populations of coupled oscillators. , 1967, Journal of theoretical biology.

[8]  M. Rook,et al.  Gap junctions in the rabbit sinoatrial node. , 2001, American journal of physiology. Heart and circulatory physiology.

[9]  J Lekieffre,et al.  [Sinoatrial node]. , 1980, Acta cardiologica.

[10]  J Jalife,et al.  Dynamic Vagal Control of Pacemaker Activity in the Mammalian Sinoatrial Node , 1983, Circulation research.

[11]  J Jalife,et al.  Chaotic Activity in a Mathematical Model of the Vagally Driven Sinoatrial Node , 1989, Circulation research.

[12]  H Zhang,et al.  Mathematical models of action potentials in the periphery and center of the rabbit sinoatrial node. , 2000, American journal of physiology. Heart and circulatory physiology.

[13]  A V Holden,et al.  Control of re-entrant activity in a model of mammalian atrial tissue , 1995, Proceedings of the Royal Society of London. Series B: Biological Sciences.

[14]  A E Becker,et al.  Functional and Morphological Organization of the Rabbit Sinus Node , 1980, Circulation research.

[15]  L Glass,et al.  Discontinuities in phase-resetting experiments. , 1984, The American journal of physiology.

[16]  A. Holden,et al.  Characteristics of atrial re-entry and meander computed from a model of a rabbit single atrial cell. , 1995, Journal of theoretical biology.

[17]  Dimitrios I. Fotiadis,et al.  Phase response characteristics of sinoatrial node cells , 2007, Comput. Biol. Medicine.

[18]  A. Winfree When time breaks down , 1987 .

[19]  J. Jalife,et al.  Cardiac Electrophysiology: From Cell to Bedside , 1990 .

[20]  H Honjo,et al.  The sinoatrial node, a heterogeneous pacemaker structure. , 2000, Cardiovascular research.

[21]  L Glass,et al.  Apparent discontinuities in the phase-resetting response of cardiac pacemakers. , 2004, Journal of theoretical biology.

[22]  A. C. F. Coster,et al.  Phase Response of Model Sinoatrial Node Cells , 2003, Annals of Biomedical Engineering.