Wide band measurements in time domain with current and voltage probes for power losses evaluation and EMC measurements on power converters
暂无分享,去创建一个
Current and voltage signal must be correctly measured in order to evaluate accurately power losses and electromagnetic interferences in time domain. This paper proposes a way to compensate the measured signals using the gain of the probes and an evaluation of the Common Mode Rejection Ratio of the differential voltage probe. Deconvolution shows its efficiency: the shape of the signal and the phase shift between current and voltage after compensation allow an accurate measurement of the power losses. Common Mode Rejection Ratio estimation shows that it is constant for the studied amplitude levels and there is low impact on the differential voltage measurements.
[1] Jian Zhou,et al. On the measurement of common-mode rejection ratio , 2005, IEEE Trans. Circuits Syst. II Express Briefs.
[3] Tsuyoshi Funaki,et al. Proposal for Measurement Method of Transfer Impedance of Current Probe , 2014, IEEE Transactions on Electromagnetic Compatibility.
[4] C. Vollaire,et al. EMI circuit modeling of a power train on composite ground plane , 2010, 2010 IEEE International Symposium on Electromagnetic Compatibility.
[5] Valter Mariani Primiani,et al. Wide-band characterization of current probes , 2003 .