Speckle reduction in pulse-echo ultrasonic imaging using a two-dimensional receiving array
暂无分享,去创建一个
C.R. Meyer | C. Meyer | P. Carson | J. Giesey | D. Fitting | P.L. Carson | D.W. Fitting | J.J. Giesey
[1] S.W. Smith,et al. The Maltese Cross Processor: Speckle Reduction for Circular Transducers , 1988, Ultrasonic imaging.
[2] G E Trahey,et al. A Quantitative Approach to Speckle Reduction via Frequency Compounding , 1986, Ultrasonic imaging.
[3] O. T. von Ramm,et al. Speckle Reduction In Medical Ultrasound Via Spatial Compounding , 1986, Other Conferences.
[4] C. Meyer,et al. Fast Envelope Detection for Thinned Display of Finely Digitized Ultrasound Scans , 1985, IEEE Transactions on Biomedical Engineering.
[5] C.R. Meyer,et al. Error Reduction in Through Transmission Tomography Using Large Receiving Arrays with Phase-Insensitive Signal Processing , 1984, IEEE Transactions on Sonics and Ultrasonics.
[6] F. Foster,et al. The Improvement and Quantitative Assessment of B-Mode Images Produced by an Annular Array/Cone Hybrid , 1983 .
[7] R. F. Wagner,et al. Statistics of Speckle in Ultrasound B-Scans , 1983, IEEE Transactions on Sonics and Ultrasonics.
[8] O. V. von Ramm,et al. Delay Quantization Error in Phased Array Images , 1981, IEEE Transactions on Sonics and Ultrasonics.
[9] S.W. Smith,et al. A multiple frequency array for improved diagnostic imaging , 1978, IEEE Transactions on Sonics and Ultrasonics.
[10] Mauri Luukkala,et al. The impulse response and pressure nearfield of a curved ultrasonic radiator , 1976 .
[11] P. Stepanishen. Transient Radiation from Pistons in an Infinite Planar Baffle , 1970 .
[12] Paul L. Carson,et al. Micromachining for improvement of integrated ultrasonic transducer sensitivity , 1990 .
[13] R.L. Galloway,et al. A frequency diversity process for speckle reduction in real-time ultrasonic images , 1988, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.
[14] P. Carson,et al. A Two-Dimensional Array Receiver for Reducing Refraction Artifacts in Ultrasonic Computed Tomography of Attenuation , 1987, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.
[15] J.G. Miller,et al. Phase-Insensitive Detection for Measurement of Backscattered Ultrasound , 1986, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.
[16] S.W. Smith,et al. Speckle Pattern Correlation with Lateral Aperture Translation: Experimental Results and Implications for Spatial Compounding , 1986, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.
[17] P. Carson,et al. Directivity and Sensitivity with Phase-Insensitive Arrays Used for Ultrasonic Measurements of Tissue Characteristics , 1986, IEEE 1986 Ultrasonics Symposium.
[18] C. Burckhardt. Speckle in ultrasound B-mode scans , 1978, IEEE Transactions on Sonics and Ultrasonics.
[19] J. G. Abbott,et al. Multi-Scan Processing in a Phased Array Imaging System , 1978 .