Drop in Combined Sewer Manhole for Supercritical Flow

Manholes often contain small drops for various reasons, the most important being submergence. While this may be appropriate for subcritical flow, its effect was considered doubtful for supercritical flow. This note aims at investigating the effect of a manhole drop on the hydraulics of sewer flow. Based on systematic experimental observations, the flow pattern associated with a manhole drop was established. A distinction was also made between small and intermediate drops. Then, the main wave features were analyzed to result in expressions that contain both the upstream filling ratio and the Froude number of the approach flow. In addition, the discharge capacity was also investigated, and selected photographs show typical drop flow in combined sewer manholes. The result of the present study is evident, based on these observations, and recommendations towards future design of combined sewer manholes are also made.