New technique for electrostatic charge measurement in gas–solid fluidized beds

Abstract Electrostatic charge generation within gas–solid fluidized bed reactors has been a concern to industry for many years. Over the years, numerous methods for measuring this phenomenon within a fluidization column have been proposed. This paper focuses on the design of a new method that minimizes effects such as extra charging due to particle handling and bed hydrodynamic disruption due to the location of the measurement device. In addition, the new method provides the bulk charge of the bed particles rather than a local measurement. The device is flexible and can be adapted to a range of fluidization columns. The new method developed consisted of a Faraday cup placed within the windbox of a fluidization column. The distributor plate was designed in such a way that it can be automatically opened to drop the charged fluidizing particles into the Faraday cup below. The new measurement technique was validated by conducting fluidization experiments in a system consisting of a 0.10 m in diameter carbon steel column with glass beads as the fluidizing particles. The technique was proven to be suitable for measuring the total net electrostatic charges in gas–solid fluidized beds.

[1]  J. Guardiola,et al.  Electrostatic behaviour in binary dielectric/conductor fluidized beds , 1992 .

[2]  I. Inculet,et al.  Minority charge separation in falling particles with bipolar charge , 1998 .

[3]  Jesús Guardiola,et al.  Influence of particle size, fluidization velocity and relative humidity on fluidized bed electrostatics , 1996 .

[4]  A. Gajewski,et al.  Investigation of the electrification of polypropylene particles during the fluidization process , 1985 .

[5]  S. Soo,et al.  Measurement of electrostatic charges and concentration of particles in the freeboard of a fluidized bed , 1982 .

[6]  H. Bi,et al.  Electrostatic behavior of different fines added to a Faraday cup fluidized bed , 2007 .

[7]  A. Wolny,et al.  Electric charge neutralization by addition of fines to a fluidized bed composed of coarse dielectric particles , 1983 .

[8]  A. Wolny,et al.  Triboelectrification in fluidized bed of polystyrene , 1989 .

[9]  A. Bailey,et al.  Bipolar charging in polydisperse polymer powders in industrial processes , 2000, Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129).

[10]  J. Rantanen,et al.  Electrostatic measurements on a miniaturized fluidized bed , 2003 .

[11]  I. Inculet,et al.  CHARGING OF POLYMER POWDER INSIDE A METALLIC FLUIDIZED BED , 1999 .

[12]  V. Rojo,et al.  A capacitor model to interpret the electric behaviour of fluidized beds. Influence of apparatus geometry , 1986 .

[13]  J. Beňa,et al.  Quantitative data on the lowering of electrostatic charge in a fluidized bed , 1972 .

[14]  H. Bi,et al.  Electrostatic charge generation in gas–solid fluidized beds , 2005 .

[15]  A. Wlodarski,et al.  On electrostatic effects in fluidized beds , 1962 .

[16]  Robert Pfeffer,et al.  A METHOD TO MEASURE ELECTROSTATIC CHARGE ON A GRANULE IN A FLUIDIZED BED , 1980 .

[17]  Hsiaotao Bi,et al.  Reduction of electrostatic charges in gas–solid fluidized beds , 2002 .

[18]  Derek Geldart,et al.  Electrostatic charging in gas fluidised beds , 1972 .