Neutron Beam Optimization for Boron Neutron Capture Therapy Using the D-D and D-T High-Energy Neutron Sources

Abstract A monoenergetic neutron beam simulation study is carried out to determine the most suitable neutron energy for treatment of shallow and deep-seated brain tumors in the context of boron neutron capture therapy. Two figures-of-merit—the absorbed skin dose and the absorbed tumor dose at a given depth in the brain - are used to measure the neutron beam quality. Based on the results of this study, moderators, reflectors, and delimiters are designed and optimized to moderate the high-energy neutrons from the fusion reactions 2H(d,n)3He and 3H(d,n)4He down to a suitable energy spectrum. Two different computational models (MCNP and BNCT_RTPE) have been used to study the dose distribution in the brain. With the optimal beam-shaping assembly, a 1-A mixed deuteron/triton beam of energy 150 keV accelerated onto a titanium target leads to a treatment time of 1 h. The dose near the center of the brain obtained with this configuration is >65% higher than the dose from a typical spectrum produced by the Brookhaven Medical Research Reactor and is comparable to the dose obtained by other accelerator-produced neutron beams.

[1]  J. F. Briesmeister MCNP-A General Monte Carlo N-Particle Transport Code , 1993 .

[2]  G. Brownell,et al.  A Monte Carlo investigation of the dosimetric properties of monoenergetic neutron beams for neutron capture therapy. , 1991, Radiation research.

[3]  S. Costes,et al.  Designing an Epithermal Neutron Beam for Boron Neutron Capture Therapy for the Fusion Reactions 2H(d,n)3He and 3H(d,n)4He , 1998 .

[4]  R. Shefer,et al.  Accelerator-based epithermal neutron beam design for neutron capture therapy. , 1992, Medical physics.

[5]  W. S. Snyder,et al.  Estimates of absorbed fractions for monoenergetic photon sources uniformly distributed in various organs of a heterogeneous phantom. , 1974, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[6]  C. K. Wang,et al.  A neutronic study of an accelerator-based neutron irradiation facility for boron neutron capture therapy , 1989 .

[7]  E. Greenspan,et al.  Optimal beam-shaping assemblies for BNCT facilities , 1995 .

[8]  Alun G. Jones,et al.  Research in boron neutron capture synovectomy , 1997, Other Conferences.

[9]  M. Ichihashi,et al.  New thermal neutron capture therapy for malignant melanoma: melanogenesis-seeking 10B molecule-melanoma cell interaction from in vitro to first clinical trial. , 1989, Pigment cell research.

[10]  O K Harling,et al.  Monte Carlo based dosimetry and treatment planning for neutron capture therapy of brain tumors. , 1990, Basic life sciences.

[11]  D. Allen,et al.  A design study for an accelerator-based epithermal neutron beam for BNCT. , 1995, Physics in medicine and biology.

[12]  James A. Scott Photon, Electron, Proton and Neutron Interaction Data for Body Tissues ICRU Report 46. International Commission on Radiation Units and Measurements, Bethesda, 1992, $40.00 , 1993 .

[13]  M. L. Randolph,et al.  Kerma factors of elements and compounds for neutron energies below 30 MeV , 1982 .

[14]  J. Verbeke,et al.  Neutron tube design study for boron neutron capture therapy application , 1998, Proceedings of the 1999 Particle Accelerator Conference (Cat. No.99CH36366).

[15]  H. B. Liu,et al.  An improved neutron collimator for brain tumor irradiations in clinical boron neutron capture therapy. , 1996, Medical physics.

[16]  F. Chmara,et al.  High Voltage Engineering Corporation , 1971 .

[17]  D. Bleuel,et al.  Designing accelerator-based epithermal neutron beams for boron neutron capture therapy. , 1998, Medical physics.

[18]  S. Costes,et al.  Neutronics analysis of three beam-filter assemblies for an accelerator-based BNCT facility , 1997 .

[19]  A. Soloway,et al.  Boron neutron capture therapy for cancer. Realities and prospects , 1992 .

[20]  J. Coggle An Introduction to Radiobiology , 1991, British Journal of Cancer.

[21]  D. Bleuel Designing accelerator-based epithermal neutron beams for BNCT , 1997 .

[22]  D. Bleuel,et al.  Development of the neutron energy-biased in-air-figure-of-merit for predicting in-phantom BNCT neutron beam characteristics , 1998 .

[23]  N. Gupta,et al.  Evaluation of moderator assemblies for use in an accelerator-based neutron source for boron neutron capture therapy , 1998 .

[24]  D. Nigg Methods for radiation dose distribution analysis and treatment planning in boron neutron capture therapy. , 1994, International journal of radiation oncology, biology, physics.

[25]  D. Bleuel,et al.  On optimizing the {sup 7}Li(p,n) proton beam energy and moderator material for BNCT , 1997 .

[26]  J. Capala,et al.  130 Boron neutron capture therapy for glioblastoma multiforme: Results from the third contemporary clinical phase I/II dose escalation study at the Brookhaven medical research reactor , 1999 .