The safety of common steel beam/column connections in fire

This paper summarises recent experimental research on structural steel I-section beam/column connections for fire safety, based on a programme of research on robustness of different types of steel beam/column connections, carried out in collaboration between the Universities of Sheffield and Manchester. In this research project, two series of connection tests were conducted, one on isolated connections under different combinations of axial load, shear and moment at different elevated temperatures, and one on steel beam-to-column assemblies in fire, in which the resulting connection forces were varied during the fire exposure. This paper summarises the results and the main findings of these tests, focusing on connection failure modes, tying resistance, the rotation capacity of different types of connection and their potential influences on fire resistance of the connected members. The principal objective of this paper is to discuss the implications of this research project on integrating fire resistance into the design of steel-framed structures, firstly to highlight connection characteristics which contribute most to overall robustness, and to suggest how connection detailing might change to enable connections to possess such desirable characteristics.

[1]  Yong Wang,et al.  A simplified analysis of catenary action in steel beams in fire and implications on fire resistant design , 2006 .

[2]  Yong Wang,et al.  A Simple Method to Predict Temperatures in Steel Joints with Partial Intumescent Coating Fire Protection , 2009 .

[3]  Florian M. Block,et al.  The development of a component-based connection element for endplate connections in fire , 2007 .

[4]  Khalifa S. Al-Jabri,et al.  Spring-stiffness model for flexible end-plate bare-steel joints in fire , 2005 .

[5]  Ulf Wickström,et al.  Comments on calculation of temperature in fire-exposed bare steel structures in prEN 1993-1-2: Eurocode 3—design of steel structures—Part 1–2: general rules—structural fire design , 2005 .

[6]  Ian Burgess,et al.  Experimental and Numerical Investigations of the Behaviour of Flush Endplate Connections at Elevated Temperatures , 2010 .

[7]  Roger J. Plank,et al.  Tying capacity of web cleat connections in fire, Part 1: Test and finite element simulation , 2009 .

[8]  Yong Wang,et al.  Effects of partial fire protection on temperature developments in steel joints protected by intumescent coating , 2009 .

[9]  Bre,et al.  ELEVATED-TEMPERATURE MOMENT-ROTATION TESTS ON STEELWORK CONNECTIONS. , 1997 .

[10]  Yong Wang,et al.  A numerical study of large deflection behaviour of restrained steel beams at elevated temperatures , 2004 .

[11]  Yong Wang,et al.  Numerical modelling of structural fire behaviour of restrained steel beam-column assemblies using typical joint types , 2010 .

[12]  Florian M. Block,et al.  The Practical Application of Structural Fire Engineering on a Retail Development in the UK , 2010 .

[13]  Ian Burgess,et al.  Experimental investigation of the behaviour of fin plate connections in fire , 2009 .