Myocardial first pass perfusion: Steady‐state free precession versus spoiled gradient echo and segmented echo planar imaging

The imaging sequences used in first pass (FP) perfusion to date have important limitations in contrast‐to‐noise ratio (CNR), temporal and spatial resolution, and myocardial coverage. As a result, controversy exists about optimal imaging strategies for FP myocardial perfusion. Since imaging performance varies from subject to subject, it is difficult to form conclusions without direct comparison of different sequences in the same subject. The purpose of this study was to directly compare the saturation recovery SSFP technique to other more commonly used myocardial first pass perfusion techniques, namely spoiled GRE and segmented EPI. Differences in signal‐to‐noise ratio (SNR), CNR, relative maximal upslope (RMU) of signal amplitude, and artifacts at comparable temporal and spatial resolution among the three sequences were investigated in computer simulation, contrast agent doped phantoms, and 16 volunteers. The results demonstrate that SSFP perfusion images exhibit an improvement of approximately 77% in SNR and 23% in CNR over spoiled GRE and 85% SNR and 50% CNR over segmented EPI. Mean RMU was similar between SSFP and spoiled GRE, but there was a 58% increase in RMU with SSFP versus segmented EPI. Magn Reson Med, 2005. © 2005 Wiley‐Liss, Inc.

[1]  R. Edelman,et al.  First-pass cardiac perfusion: evaluation with ultrafast MR imaging. , 1990, Radiology.

[2]  Michael Jerosch-Herold,et al.  Direct comparison of an intravascular and an extracellular contrast agent for quantification of myocardial perfusion , 1999, The International Journal of Cardiac Imaging.

[3]  H Rusinek,et al.  Optimal dose of Gd‐DTPA in dynamic MR studies , 2001, Magnetic resonance in medicine.

[4]  Klaus Scheffler,et al.  Arterial first pass gadolinium‐CM dynamics as a function of several intravenous saline flush and Gd volumes , 2001, Journal of magnetic resonance imaging : JMRI.

[5]  C M Kramer,et al.  Usefulness of magnetic resonance imaging early after acute myocardial infarction. , 1997, The American journal of cardiology.

[6]  Ying Wang,et al.  Regional myocardial blood volume and flow: First‐pass MR imaging with polylysine‐Gd‐DTPA , 1995, Journal of magnetic resonance imaging : JMRI.

[7]  E M Haacke,et al.  Partial Fourier imaging in multi‐dimensions: A means to save a full factor of two in time , 2001, Journal of magnetic resonance imaging : JMRI.

[8]  D. Peters,et al.  Multislice first‐pass cardiac perfusion MRI: Validation in a model of myocardial infarction † , 2002, Magnetic resonance in medicine.

[9]  E R McVeigh,et al.  Multi‐echo segmented k‐space imaging: An optimized hybrid sequence for ultrafast cardiac imaging , 1999, Magnetic resonance in medicine.

[10]  G Laub,et al.  3D magnetization‐prepared true‐FISP: A new technique for imaging coronary arteries , 2001, Magnetic resonance in medicine.

[11]  R. Edelman,et al.  Band artifacts due to bulk motion , 2002, Magnetic resonance in medicine.

[12]  O. Simonetti,et al.  TrueFISP: Assessment of accuracy for measurement of left ventricular mass in an animal model , 2002, Journal of magnetic resonance imaging : JMRI.

[13]  Didier Revel,et al.  Influence of bolus volume and dose of gadolinium chelate for first‐pass myocardial perfusion MR imaging studies , 1995, Journal of magnetic resonance imaging : JMRI.

[14]  J Schwitter,et al.  Magnetic resonance myocardial first‐pass perfusion imaging: Parameter optimization for signal response and cardiac coverage , 2001, Journal of magnetic resonance imaging : JMRI.

[15]  R R Edelman,et al.  Contrast-enhanced echo-planar MR imaging of myocardial perfusion: preliminary study in humans. , 1994, Radiology.

[16]  Yu-Chung N. Cheng,et al.  Magnetic Resonance Imaging: Physical Principles and Sequence Design , 1999 .

[17]  S. Wolff,et al.  First-pass myocardial perfusion MR imaging with interleaved notched saturation: feasibility study. , 2001, Radiology.

[18]  M. Schmitt,et al.  Dynamic contrast‐enhanced myocardial perfusion imaging using saturation‐prepared TrueFISP , 2002, Journal of magnetic resonance imaging : JMRI.

[19]  Klaus Scheffler,et al.  On the transient phase of balanced SSFP sequences , 2003, Magnetic resonance in medicine.