Theoretically exact backprojection filtration algorithm for multi-segment linear trajectory

A theoretically exact backprojection filtration algorithm is proved and implemented for image reconstruction from a multi-segment linear trajectory assuming fan-beam geometry. The reconstruction formula is based on a concept of linear PI-line (L-PI) proposed in our previous work. The proof is completed in two consecutive steps. In the first step, it is proved that theoretically exact image reconstruction can be obtained on an arbitrary L-PI line from an infinite straight-line trajectory. In the second step, it is shown that accurate image reconstruction can be achieved from a multi-segment line trajectory by introducing a weight function to deal with the data redundancy. Numerical implementation and simulation results validate the correctness of our theoretical results.

[1]  Hiroyuki Kudo,et al.  Image reconstruction from fan-beam projections on less than a short scan , 2002, Physics in medicine and biology.

[2]  Ge Wang,et al.  Approximate and exact cone-beam reconstruction with standard and non-standard spiral scanning , 2007 .

[3]  Li Zhang,et al.  An Improved Form of Linogram Algorithm for Image Reconstruction , 2008, IEEE Transactions on Nuclear Science.

[4]  F. Noo,et al.  A two-step Hilbert transform method for 2D image reconstruction. , 2004, Physics in medicine and biology.

[5]  Li Zhang,et al.  Straight-Line-Trajectory-Based X-Ray Tomographic Imaging for Security Inspections: System Design, Image Reconstruction and Preliminary Results , 2013, IEEE Transactions on Nuclear Science.

[6]  Hengyong Yu,et al.  A unified framework for exact cone-beam reconstruction formulas. , 2005, Medical physics.

[7]  Li Zhang,et al.  Volumetric imaging from a multisegment straight-line trajectory and a practical reconstruction algorithm , 2007 .

[8]  K Wells,et al.  A review of X-ray explosives detection techniques for checked baggage. , 2012, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[9]  Hengyong Yu,et al.  BPF-type region-of-interest reconstruction for parallel translational computed tomography. , 2017, Journal of X-ray science and technology.

[10]  James T Dobbins,et al.  Digital x-ray tomosynthesis: current state of the art and clinical potential. , 2003, Physics in medicine and biology.

[11]  H. Tuy AN INVERSION FORMULA FOR CONE-BEAM RECONSTRUCTION* , 1983 .

[12]  Grant T. Gullberg,et al.  Two finite inverse Hilbert transform formulae for region-of-interest tomography , 2007 .

[13]  Li Zhang,et al.  Direct filtered-backprojection-type reconstruction from a straight-line trajectory , 2007 .

[14]  Hengyong Yu,et al.  Approximate and exact cone-beam reconstruction with standard and non-standard spiral scanning , 2006, SPIE Optics + Photonics.

[15]  Per-Erik Danielsson,et al.  Scanning of logs with linear cone-beam tomography , 2003 .

[16]  R. Clackdoyle Necessary and Sufficient Consistency Conditions for Fanbeam Projections Along a Line , 2013, IEEE Transactions on Nuclear Science.

[17]  Jiangsheng You,et al.  Explicit finite inverse Hilbert transforms , 2006 .

[18]  Gengsheng Lawrence Zeng,et al.  Two Finite Inverse Hilbert Transform Formulae for Region-of-Interest Tomography , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[19]  D. Parker Optimal short scan convolution reconstruction for fan beam CT , 1982 .

[20]  Hengyong Yu,et al.  A general exact reconstruction for cone-beam CT via backprojection-filtration , 2005, IEEE Transactions on Medical Imaging.

[21]  Alexander Katsevich,et al.  Theoretically Exact Filtered Backprojection-Type Inversion Algorithm for Spiral CT , 2002, SIAM J. Appl. Math..

[22]  Linh V. Nguyen On Artifacts in Limited Data Spherical Radon Transform: Flat Observation Surfaces , 2014, SIAM J. Math. Anal..

[23]  Emil Y. Sidky,et al.  Region of interest reconstruction from truncated data in circular cone-beam CT , 2006, IEEE Transactions on Medical Imaging.

[24]  T. Schön,et al.  A translation-based data acquisition method for computed tomography: theoretical analysis and simulation study. , 2013, Medical physics.

[25]  Jun Zhao,et al.  A Filtered Backprojection Algorithm for Triple-Source Helical Cone-Beam CT , 2009, IEEE Transactions on Medical Imaging.

[26]  Xiaochuan Pan,et al.  An extended data function and its generalized backprojection for image reconstruction in helical cone-beam CT. , 2004, Physics in medicine and biology.

[27]  Stefan Wesarg,et al.  Parker weights revisited. , 2002, Medical physics.

[28]  Tarkeshwar Singh,et al.  Fan-beam reconstruction from a straight line of source points , 1993, IEEE Trans. Medical Imaging.

[29]  F. Noo,et al.  Cone-beam reconstruction using 1D filtering along the projection of M-lines , 2005 .

[30]  M. Jiang,et al.  An exact reconstruction algorithm for triple-source helical cone-beam CT , 2006 .

[31]  Xiaochuan Pan,et al.  Volume image reconstruction from a straight-line source trajectory , 2005, IEEE Nuclear Science Symposium Conference Record, 2005.

[32]  Rolf Clackdoyle,et al.  Cone-beam reconstruction using the backprojection of locally filtered projections , 2005, IEEE Transactions on Medical Imaging.

[33]  Hengyong Yu,et al.  Analytic reconstruction approach for parallel translational computed tomography. , 2015, Journal of X-ray science and technology.

[34]  Joel S. Karp,et al.  A Method for Reconstructing Images from Data Obtained with a Hexagonal Bar Positron Camera , 1985, IEEE Transactions on Medical Imaging.

[35]  Ge Wang,et al.  PI-line-based image reconstruction in helical cone-beam computed tomography with a variable pitch. , 2005, Medical physics.

[36]  D. G. Grant Tomosynthesis: a three-dimensional radiographic imaging technique. , 1972, IEEE transactions on bio-medical engineering.

[37]  Kailash C. Kapur,et al.  Designing airport checked-baggage-screening strategies considering system capability and reliability , 2009, Reliab. Eng. Syst. Saf..

[38]  Hiroyuki Kudo,et al.  Truncated Hilbert transform and image reconstruction from limited tomographic data , 2006 .

[39]  R. Clackdoyle,et al.  Quantitative reconstruction from truncated projections in classical tomography , 2004, IEEE Transactions on Nuclear Science.

[40]  Liang Li,et al.  A general region-of-interest image reconstruction approach with truncated Hilbert transform. , 2009, Journal of X-ray science and technology.

[41]  Xiaochuan Pan,et al.  Exact image reconstruction on PI-lines from minimum data in helical cone-beam CT. , 2004, Physics in medicine and biology.

[42]  Hengyong Yu,et al.  Top-level design and pilot analysis of low-end CT scanners based on linear scanning for developing countries. , 2013, Journal of X-ray science and technology.