A high-impedance detector-array glove for magnetic resonance imaging of the hand

Densely packed resonant structures used for magnetic resonance imaging (MRI), such as nuclear magnetic resonance phased array detectors, suffer from resonant inductive coupling, which restricts the coil design to fixed geometries, imposes performance limitations and narrows the scope of MRI experiments to motionless subjects. Here, we report the design of high-impedance detectors, and the fabrication and performance of a wearable detector array for MRI of the hand, that cloak themselves from electrodynamic interactions with neighbouring elements. We experimentally verified that the detectors do not suffer from the signal-to-noise degradation mechanisms typically observed with the use of traditional low-impedance elements. The detectors are adaptive and can accommodate movement, providing access to the imaging of soft-tissue biomechanics with unprecedented flexibility. The design of the wearable detector glove exemplifies the potential of high-impedance detectors in enabling a wide range of applications that are not well suited to traditional coil designs.A flexible magnetic resonance imaging coil bearing an array of high-impedance detectors can be stitched onto a glove and used to image the biomechanics of the hand’s soft tissue.

[1]  L. Wald,et al.  A 64‐channel 3T array coil for accelerated brain MRI , 2013, Magnetic resonance in medicine.

[2]  J. Polimeni,et al.  Blipped‐controlled aliasing in parallel imaging for simultaneous multislice echo planar imaging with reduced g‐factor penalty , 2012, Magnetic resonance in medicine.

[3]  J. Polimeni,et al.  Performance evaluation of a 32‐element head array with respect to the ultimate intrinsic SNR , 2010, NMR in biomedicine.

[4]  Lau Pc,et al.  Image formation by induced local interactions. Examples employing nuclear magnetic resonance. 1973. , 1989 .

[5]  D. Larkman,et al.  Use of multicoil arrays for separation of signal from multiple slices simultaneously excited , 2001, Journal of magnetic resonance imaging : JMRI.

[6]  Michael Lustig,et al.  Screen-printed flexible MRI receive coils , 2016, Nature Communications.

[7]  Ravinder R Regatte,et al.  Design of a nested eight‐channel sodium and four‐channel proton coil for 7T knee imaging , 2013, Magnetic resonance in medicine.

[8]  Brian B. Tierney,et al.  Planar shielded-loop resonators for wireless non-radiative power transfer , 2013, 2013 IEEE Antennas and Propagation Society International Symposium (APSURSI).

[9]  L. Axel,et al.  Rapid B1+ mapping using a preconditioning RF pulse with TurboFLASH readout , 2010, Magnetic resonance in medicine.

[10]  M. Soljačić,et al.  Wireless Power Transfer via Strongly Coupled Magnetic Resonances , 2007, Science.

[11]  H. Ermert,et al.  Ultimate signal-to-noise-ratio of surface and body antennas for magnetic resonance imaging , 2000 .

[12]  Stéphane Serfaty,et al.  Multi‐turn split‐conductor transmission‐line resonators , 1997, Magnetic resonance in medicine.

[13]  Robin M Heidemann,et al.  Generalized autocalibrating partially parallel acquisitions (GRAPPA) , 2002, Magnetic resonance in medicine.

[14]  H P Hetherington,et al.  4 T Actively detuneable double-tuned 1H/31P head volume coil and four-channel 31P phased array for human brain spectroscopy. , 2006, Journal of magnetic resonance.

[15]  P. Mansfield,et al.  NMR 'diffraction' in solids? , 1973 .

[16]  A Stensgaard Planar quadrature coil design using shielded-loop resonators. , 1997, Journal of magnetic resonance.

[17]  Peter Kellman,et al.  Image reconstruction in SNR units: A general method for SNR measurement † , 2005, Magnetic resonance in medicine.

[18]  D. Sodickson,et al.  Ideal current patterns yielding optimal signal‐to‐noise ratio and specific absorption rate in magnetic resonance imaging: Computational methods and physical insights , 2012, Magnetic resonance in medicine.

[19]  E. Atalar,et al.  Ultimate intrinsic signal‐to‐noise ratio in MRI , 1998, Magnetic resonance in medicine.

[20]  Sigrun Goluch,et al.  Novel inductive decoupling technique for flexible transceiver arrays of monolithic transmission line resonators , 2015, Magnetic resonance in medicine.

[21]  Xiaoyu Yang,et al.  RF Surface Receive Array Coils: The Art of an LC Circuit , 2013, Journal of magnetic resonance imaging : JMRI.

[22]  Olaf Dössel,et al.  An Optimal Radial Profile Order Based on the Golden Ratio for Time-Resolved MRI , 2007, IEEE Transactions on Medical Imaging.

[23]  H. Rinneberg,et al.  Human cardiac imaging at 3 T using phased array coils , 2000, Magnetic resonance in medicine.

[24]  Walid S. Saba,et al.  ANALYSIS AND DESIGN , 2000 .

[25]  Christina Triantafyllou,et al.  A 128‐channel receive‐only cardiac coil for highly accelerated cardiac MRI at 3 Tesla , 2008, Magnetic resonance in medicine.

[26]  S. Kan,et al.  Parallel‐plate split‐conductor surface coil: Analysis and design , 1988, Magnetic resonance in medicine.

[27]  P. Boesiger,et al.  Electrodynamics and ultimate SNR in parallel MR imaging , 2004, Magnetic resonance in medicine.

[28]  A. Reykowski,et al.  Calculation of the signal-to-noise ratio for simple surface coils and arrays of coils [magnetic resonance imaging] , 1995, IEEE Transactions on Biomedical Engineering.

[29]  J. Polimeni,et al.  96‐Channel receive‐only head coil for 3 Tesla: Design optimization and evaluation , 2009, Magnetic resonance in medicine.

[30]  Klaus Scheffler,et al.  Three‐layered radio frequency coil arrangement for sodium MRI of the human brain at 9.4 Tesla , 2016, Magnetic resonance in medicine.

[31]  D. Sodickson,et al.  Ultimate intrinsic signal‐to‐noise ratio for parallel MRI: Electromagnetic field considerations , 2003, Magnetic resonance in medicine.

[32]  P. Lauterbur,et al.  Image Formation by Induced Local Interactions: Examples Employing Nuclear Magnetic Resonance , 1973, Nature.

[33]  Ewald Moser,et al.  Multi-turn multi-gap transmission line resonators - Concept, design and first implementation at 4.7T and 7T. , 2016, Journal of magnetic resonance.

[34]  F. Bloch,et al.  A Quantitative Determination of the Magnetic Moment of the Neutron in Units of the Proton Moment , 1948 .

[35]  P. Roemer,et al.  The NMR phased array , 1990, Magnetic resonance in medicine.

[36]  Britton Chance,et al.  A new double-tuned probed for concurrent 1H and 31P NMR☆ , 1985 .