A high-impedance detector-array glove for magnetic resonance imaging of the hand
暂无分享,去创建一个
[1] L. Wald,et al. A 64‐channel 3T array coil for accelerated brain MRI , 2013, Magnetic resonance in medicine.
[2] J. Polimeni,et al. Blipped‐controlled aliasing in parallel imaging for simultaneous multislice echo planar imaging with reduced g‐factor penalty , 2012, Magnetic resonance in medicine.
[3] J. Polimeni,et al. Performance evaluation of a 32‐element head array with respect to the ultimate intrinsic SNR , 2010, NMR in biomedicine.
[4] Lau Pc,et al. Image formation by induced local interactions. Examples employing nuclear magnetic resonance. 1973. , 1989 .
[5] D. Larkman,et al. Use of multicoil arrays for separation of signal from multiple slices simultaneously excited , 2001, Journal of magnetic resonance imaging : JMRI.
[6] Michael Lustig,et al. Screen-printed flexible MRI receive coils , 2016, Nature Communications.
[7] Ravinder R Regatte,et al. Design of a nested eight‐channel sodium and four‐channel proton coil for 7T knee imaging , 2013, Magnetic resonance in medicine.
[8] Brian B. Tierney,et al. Planar shielded-loop resonators for wireless non-radiative power transfer , 2013, 2013 IEEE Antennas and Propagation Society International Symposium (APSURSI).
[9] L. Axel,et al. Rapid B1+ mapping using a preconditioning RF pulse with TurboFLASH readout , 2010, Magnetic resonance in medicine.
[10] M. Soljačić,et al. Wireless Power Transfer via Strongly Coupled Magnetic Resonances , 2007, Science.
[11] H. Ermert,et al. Ultimate signal-to-noise-ratio of surface and body antennas for magnetic resonance imaging , 2000 .
[12] Stéphane Serfaty,et al. Multi‐turn split‐conductor transmission‐line resonators , 1997, Magnetic resonance in medicine.
[13] Robin M Heidemann,et al. Generalized autocalibrating partially parallel acquisitions (GRAPPA) , 2002, Magnetic resonance in medicine.
[14] H P Hetherington,et al. 4 T Actively detuneable double-tuned 1H/31P head volume coil and four-channel 31P phased array for human brain spectroscopy. , 2006, Journal of magnetic resonance.
[15] P. Mansfield,et al. NMR 'diffraction' in solids? , 1973 .
[16] A Stensgaard. Planar quadrature coil design using shielded-loop resonators. , 1997, Journal of magnetic resonance.
[17] Peter Kellman,et al. Image reconstruction in SNR units: A general method for SNR measurement † , 2005, Magnetic resonance in medicine.
[18] D. Sodickson,et al. Ideal current patterns yielding optimal signal‐to‐noise ratio and specific absorption rate in magnetic resonance imaging: Computational methods and physical insights , 2012, Magnetic resonance in medicine.
[19] E. Atalar,et al. Ultimate intrinsic signal‐to‐noise ratio in MRI , 1998, Magnetic resonance in medicine.
[20] Sigrun Goluch,et al. Novel inductive decoupling technique for flexible transceiver arrays of monolithic transmission line resonators , 2015, Magnetic resonance in medicine.
[21] Xiaoyu Yang,et al. RF Surface Receive Array Coils: The Art of an LC Circuit , 2013, Journal of magnetic resonance imaging : JMRI.
[22] Olaf Dössel,et al. An Optimal Radial Profile Order Based on the Golden Ratio for Time-Resolved MRI , 2007, IEEE Transactions on Medical Imaging.
[23] H. Rinneberg,et al. Human cardiac imaging at 3 T using phased array coils , 2000, Magnetic resonance in medicine.
[24] Walid S. Saba,et al. ANALYSIS AND DESIGN , 2000 .
[25] Christina Triantafyllou,et al. A 128‐channel receive‐only cardiac coil for highly accelerated cardiac MRI at 3 Tesla , 2008, Magnetic resonance in medicine.
[26] S. Kan,et al. Parallel‐plate split‐conductor surface coil: Analysis and design , 1988, Magnetic resonance in medicine.
[27] P. Boesiger,et al. Electrodynamics and ultimate SNR in parallel MR imaging , 2004, Magnetic resonance in medicine.
[28] A. Reykowski,et al. Calculation of the signal-to-noise ratio for simple surface coils and arrays of coils [magnetic resonance imaging] , 1995, IEEE Transactions on Biomedical Engineering.
[29] J. Polimeni,et al. 96‐Channel receive‐only head coil for 3 Tesla: Design optimization and evaluation , 2009, Magnetic resonance in medicine.
[30] Klaus Scheffler,et al. Three‐layered radio frequency coil arrangement for sodium MRI of the human brain at 9.4 Tesla , 2016, Magnetic resonance in medicine.
[31] D. Sodickson,et al. Ultimate intrinsic signal‐to‐noise ratio for parallel MRI: Electromagnetic field considerations , 2003, Magnetic resonance in medicine.
[32] P. Lauterbur,et al. Image Formation by Induced Local Interactions: Examples Employing Nuclear Magnetic Resonance , 1973, Nature.
[33] Ewald Moser,et al. Multi-turn multi-gap transmission line resonators - Concept, design and first implementation at 4.7T and 7T. , 2016, Journal of magnetic resonance.
[34] F. Bloch,et al. A Quantitative Determination of the Magnetic Moment of the Neutron in Units of the Proton Moment , 1948 .
[35] P. Roemer,et al. The NMR phased array , 1990, Magnetic resonance in medicine.
[36] Britton Chance,et al. A new double-tuned probed for concurrent 1H and 31P NMR☆ , 1985 .