Introduction: High-frequency (HF) spinal cord stimulation (SCS), a relatively new form of spinal cord stimulation, provides stimulation frequencies of up to 10 kHz and allows for paresthesia-free pain relief, an advantage that distinguishes it from traditional stimulation therapy. Without paresthesias, patients with HF SCS do not experience position-dependent painful stimulation and do not have to experience treatment interruption during sleep. Lead migration is a well-known complication of conventional spinal cord stimulation and usually results in a loss of efficacy along with other unpleasant sensory symptoms. In this case report, we present an incidence of lead migration in HF SCS that resulted in paresthesias, a symptom not expected to occur in this novel therapy. Case: The patient, a 60-year-old female with post-laminectomy syndrome, underwent a trial of HF SCS with standard lead placement at T8-T9. She initially had pain relief, but returned to the office on post-operative day 2 complaining of left chest wall and cardiac paresthesias, without frank pain or palpitations, in addition to loss of efficacy for her back and leg pain. Imaging showed that the leads had migrated, with one lead reaching the levels of T1-T3. Conclusion: While HF SCS has emerged as an effective paresthesia-free means of reducing back and leg pain, we provide the first report of paresthesias occurring with the HF SCS system as a result of cephalad lead migration. As HF SCS is only now being utilized as a treatment modality, we must remain cautious of potential adverse outcomes in patients, in particular above T8.
[1]
W. Beckworth,et al.
Cephalad Lead Migration During a Spinal Cord Stimulation Trial: A Case Presentation
,
2018,
PM & R : the journal of injury, function, and rehabilitation.
[2]
Kevin L Kilgore,et al.
Computational Analysis of Kilohertz Frequency Spinal Cord Stimulation for Chronic Pain Management
,
2015,
Anesthesiology.
[3]
Marc Russo,et al.
10-kHz High-Frequency SCS Therapy: A Clinical Summary
,
2014,
Pain medicine.
[4]
Enrico Ravera,et al.
Significant Cephalad Paddle‐Lead Migration After Lumbar Spinal Cord Stimulation Implant
,
2014,
Neuromodulation : journal of the International Neuromodulation Society.
[5]
G. Barolat,et al.
Spinal Geometry and Paresthesia Coverage in Spinal Cord Stimulation
,
1998,
Neuromodulation : journal of the International Neuromodulation Society.
[6]
S. Palmisani,et al.
High‐Frequency Spinal Cord Stimulation for the Treatment of Chronic Back Pain Patients: Results of a Prospective Multicenter European Clinical Study
,
2013,
Neuromodulation : journal of the International Neuromodulation Society.
[7]
J Holsheimer,et al.
Significance of the spinal cord position in spinal cord stimulation.
,
1995,
Acta neurochirurgica. Supplement.