Eight-Switch Power Conditioner for Current Harmonic Compensation and Voltage Sag Mitigation

The nine-switch converter has been proposed recently, and since then, a large number of applications have been investigated, particularly as a substitute to the dual-bridge (back-to-back) converter. The main advantage of the nine-switch converter is its lesser number of switches (9 instead of 12 of the back-to-back converter), which has, as a tradeoff, some restrictions in the total attainable amplitude at its outputs, dependent on the phase shift between its two terminal sets. However, with an appropriately designed control scheme, the nine-switch converter is shown to favorably raise the overall power quality, justifying its role as a power conditioner at a reduced semiconductor cost. The proposed power conditioner has only eight switches, being composed by a unit for voltage sag mitigation and another unit for current harmonic compensation. Simulation and experimental results confirm the validity of the proposed method.

[1]  Hatem H. Zeineldin,et al.  A Noniterative Optimized Algorithm for Shunt Active Power Filter Under Distorted and Unbalanced Supply Voltages , 2013, IEEE Transactions on Industrial Electronics.

[2]  Hurng-Liahng Jou,et al.  Novel Circuit Topology for Three-Phase Active Power Filter , 2007, IEEE Transactions on Power Delivery.

[3]  H. Akagi,et al.  A practical approach to harmonic compensation in power systems-series connection of passive and active filters , 1990, Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting.

[4]  Luiz G. B. Genu,et al.  Transformerless Hybrid Power Filter Based on a Six-Switch Two-Leg Inverter for Improved Harmonic Compensation Performance , 2015, IEEE Transactions on Industrial Electronics.

[5]  F. Blaabjerg,et al.  A detailed comparison of system topologies for dynamic voltage restorers , 2005, IEEE Transactions on Industry Applications.

[6]  Ebrahim Babaei,et al.  Sensitive load voltage compensation against voltage sags/swells and harmonics in the grid voltage and limit downstream fault currents using DVR , 2012 .

[7]  Poh Chiang Loh,et al.  An Integrated Nine-Switch Power Conditioner for Power Quality Enhancement and Voltage Sag Mitigation , 2012, IEEE Transactions on Power Electronics.

[8]  Sean Elphick,et al.  The 230 V CBEMA curve — Preliminary studies , 2010, 2010 20th Australasian Universities Power Engineering Conference.

[9]  J.V. Milanovic,et al.  Sensitivity of personal computers to voltage sags and short interruptions , 2005, IEEE Transactions on Power Delivery.

[10]  Hadi Youssef Kanaan,et al.  Vienna Rectifier With Power Quality Added Function , 2014, IEEE Transactions on Industrial Electronics.

[11]  Hirofumi Akagi,et al.  Active Harmonic Filters , 2005, Proceedings of the IEEE.

[12]  Ebrahim Babaei,et al.  Mitigation of Voltage Disturbances Using Dynamic Voltage Restorer Based on Direct Converters , 2010, IEEE Transactions on Power Delivery.

[13]  Marcelo Lobo Heldwein,et al.  Active Power Filter Control Strategy With Implicit Closed-Loop Current Control and Resonant Controller , 2013, IEEE Transactions on Industrial Electronics.

[14]  W. Kranz,et al.  Are voltage sags destroying equipment? , 2006, IEEE Industry Applications Magazine.

[15]  Luca Consolini,et al.  Active Filter for the Removal of the DC Current Component for Single-Phase Power Lines , 2013, IEEE Transactions on Industrial Electronics.

[16]  H Fujita,et al.  A dynamic voltage restorer equipped with a high-frequency isolated dc-dc converter , 2009, 2009 IEEE Energy Conversion Congress and Exposition.

[17]  Hirofumi Akagi,et al.  A medium-voltage transformerless AC/DC power conversion system consisting of a diode rectifier and a shunt hybrid filter , 2002 .

[18]  Quoc-Nam Trinh,et al.  An Advanced Current Control Strategy for Three-Phase Shunt Active Power Filters , 2013, IEEE Transactions on Industrial Electronics.