Computer modeling of deployment and mechanical expansion of neurovascular flow diverter in patient-specific intracranial aneurysms.

Flow diverter (FD) is an emerging neurovascular device based on self-expandable braided stent for treating intracranial aneurysms. Variability in FD outcome has underscored a need for investigating the hemodynamic effect of fully deployed FD in patient-specific aneurysms. Image-based computational fluid dynamics, which can provide important hemodynamic insight, requires accurate representation of FD in deployed states. We developed a finite element analysis (FEA) based workflow for simulating mechanical deployment of FD in patient-specific aneurysms. We constructed FD models of interlaced wires emulating the Pipeline Embolization Device, using 3D finite beam elements to account for interactions between stent strands, and between the stent and other components. The FEA analysis encompasses all steps that affect the final deployed configuration including stent crimping, delivery and expansion. Besides the stent, modeling also includes key components of the FD delivery system such as microcatheter, pusher, and distal coil. Coordinated maneuver of these components allowed the workflow to mimic clinical operation of FD deployment and to explore clinical strategies. The workflow was applied to two patient-specific aneurysms. Parametric study indicated consistency of the deployment result against different friction conditions, but excessive intra-stent friction should be avoided. This study demonstrates for the first time mechanical modeling of braided FD stent deployment in cerebral vasculature to produce realistic deployed configuration, thus paving the way for accurate CFD analysis of flow diverters for reliable prediction and optimization of treatment outcome.

[1]  C. Putman,et al.  Aneurysm Rupture Following Treatment with Flow-Diverting Stents: Computational Hemodynamics Analysis of Treatment , 2010, American Journal of Neuroradiology.

[2]  Z Kulcsar,et al.  Treatment of Intracranial Aneurysms by Functional Reconstruction of the Parent Artery: The Budapest Experience with the Pipeline Embolization Device , 2010, American Journal of Neuroradiology.

[3]  Alan J. Waring,et al.  The Formulated Microbicide RC-101 Was Safe and Antivirally Active Following Intravaginal Application in Pigtailed Macaques , 2010, PloS one.

[4]  P. Lylyk,et al.  The Pipeline Embolization Device for the Intracranial Treatment of Aneurysms Trial , 2010, American Journal of Neuroradiology.

[5]  Tae Jin Kang,et al.  Mechanical modeling of self-expandable stent fabricated using braiding technology. , 2008, Journal of biomechanics.

[6]  Aike Qiao,et al.  Numerical simulation of hemodynamics in stented internal carotid aneurysm based on patient-specific model. , 2010, Journal of biomechanics.

[7]  Adnan H Siddiqui,et al.  Panacea or problem: flow diverters in the treatment of symptomatic large or giant fusiform vertebrobasilar aneurysms. , 2012, Journal of neurosurgery.

[8]  J. Xiang,et al.  Alteration of intra-aneurysmal hemodynamics for flow diversion using enterprise and vision stents. , 2010, World neurosurgery.

[9]  Rolf Vogel,et al.  Incomplete Stent Apposition and Very Late Stent Thrombosis After Drug-Eluting Stent Implantation , 2007, Circulation.

[10]  Hui Meng,et al.  Comparison of Two Stents in Modifying Cerebral Aneurysm Hemodynamics , 2008, Annals of Biomedical Engineering.

[11]  Pascal Verdonck,et al.  Virtual optimization of self-expandable braided wire stents. , 2009, Medical engineering & physics.

[12]  C. Clerc,et al.  A study of the geometrical and mechanical properties of a self-expanding metallic stent--theory and experiment. , 1993, Journal of applied biomaterials : an official journal of the Society for Biomaterials.

[13]  H Handa,et al.  Stiffness and elastic behavior of human intracranial and extracranial arteries. , 1980, Journal of biomechanics.

[14]  S. Renowden,et al.  Intra-Aneurysmal Thrombosis as a Possible Cause of Delayed Aneurysm Rupture after Flow-Diversion Treatment , 2010, American Journal of Neuroradiology.

[15]  Alejandro F. Frangi,et al.  Fast virtual deployment of self-expandable stents: Method and in vitro evaluation for intracranial aneurysmal stenting , 2012, Medical Image Anal..

[16]  Ken Ikeuchi,et al.  Contact and friction between catheter and blood vessel , 2007 .

[17]  Carlos Miranda,et al.  CURATIVE ENDOVASCULAR RECONSTRUCTION OF CEREBRAL ANEURYSMS WITH THE PIPELINE EMBOLIZATION DEVICE: THE BUENOS AIRES EXPERIENCE , 2009, Neurosurgery.

[18]  David F Kallmes,et al.  Flow Diversion for Intracranial Aneurysms: A Review , 2011, Stroke.

[19]  Naofumi Hayabuchi,et al.  Conformity of carotid stents with vascular anatomy: evaluation in carotid models. , 2004, AJNR. American journal of neuroradiology.

[20]  Jacqueline Birks,et al.  Early Experience in the Treatment of Intra-Cranial Aneurysms by Endovascular Flow Diversion: A Multicentre Prospective Study , 2010, PloS one.

[21]  Nuno Rebelo,et al.  Study of a Nitinol Stent Deployed into Anatomically Accurate Artery Geometry and Subjected to Realistic Service Loading , 2009, Journal of Materials Engineering and Performance.

[22]  Min Qi,et al.  Delivery and release of nitinol stent in carotid artery and their interactions: a finite element analysis. , 2007, Journal of biomechanics.

[23]  Jonathan Black,et al.  Handbook of Biomaterial Properties , 1998, Springer US.

[24]  J. Gau,et al.  Comparative friction of orthodontic wires under dry and wet conditions. , 1986, American journal of orthodontics.

[25]  Adnan H Siddiqui,et al.  Retrograde Trans-Posterior Communicating Artery Snare-Assisted Rescue of Lost Access to a Foreshortened Pipeline Embolization Device: Complication Management , 2010, Neurosurgery.

[26]  A. Malek,et al.  Delivery technique plays an important role in determining vessel wall apposition of the Enterprise self-expanding intracranial stent , 2011, Journal of NeuroInterventional Surgery.

[27]  Rainald Löhner,et al.  Computational fluid dynamics of stented intracranial aneurysms using adaptive embedded unstructured grids , 2008 .