Automated on-line dispersive liquid–liquid microextraction based on a sequential injection system

Abstract A novel approach for sequential injection-dispersive liquid–liquid microextraction (SI-DLLME) has been suggested. The method is based on the aspiration and mixing of a sample and all required aqueous reagents in the holding coil of an SIA system, delivering it into a conical tube and adding in a mixture of extraction solvent, auxiliary solvent and disperser solvent at high flow rate, resulting in the formation of a cloudy state and the extraction of an analyte. The mixture of extraction and auxiliary solvent is immiscible with water and has a density significantly higher than that of water; consequently, the resulting fine droplets in the mixture, which contain the extracted analyte, are self-sedimented in a short time at the bottom of conical tube. Thus, no centrifugation and no use of a microcolumn are required for separation of the extraction phase. Afterwards, the extracted analyte is aspirated and transferred to a micro-volume Z-flow cell, and the absorbance is measured. The performance of the suggested approach is demonstrated by the SI-DLLME of thiocyanate ions in the form of ion associate with dimethylindocarbocyanine reagent, followed by spectrophotometric detection. A mixture of amyl acetate (as extraction solvent), tetrachloromethane (as auxiliary solvent) and acetonitrile (as disperser solvent) was selected for the DLLME procedure. The appropriate experimental conditions for conventional DLLME and automated SI-DLLME were investigated. The analytical performance of both these procedures was compared. The absorbance of the colored extracts at wavelength 555 nm obeys Beer's law in the range of 3.13–28.2 for conventional DLLME and 0.29–5.81 mg L− 1 of SCN for SI-DLLME, and the limit of detection, calculated from a blank test based on 3 s, is 0.110 for conventional DLLME and 0.017 mg L− 1 for SI-DLLME.

[1]  A. Anthemidis,et al.  On-line sequential injection dispersive liquid-liquid microextraction system for flame atomic absorption spectrometric determination of copper and lead in water samples. , 2009, Talanta.

[2]  A. Anthemidis,et al.  Sequential injection dispersive liquid-liquid microextraction based on fatty alcohols and poly(etheretherketone)-turnings for metal determination by flame atomic absorption spectrometry. , 2011, Talanta.

[3]  Francisco Pena-Pereira,et al.  Miniaturized preconcentration methods based on liquid–liquid extraction and their application in inorganic ultratrace analysis and speciation: A review , 2009 .

[4]  D. Djozan,et al.  Use of a capillary tube for collecting an extraction solvent lighter than water after dispersive liquid-liquid microextraction and its application in the determination of parabens in different samples by gas chromatography--flame ionization detection. , 2010, Talanta.

[5]  A. Anthemidis,et al.  Development of a sequential injection dispersive liquid-liquid microextraction system for electrothermal atomic absorption spectrometry by using a hydrophobic sorbent material: determination of lead and cadmium in natural waters. , 2010, Analytica chimica acta.

[6]  Vasil Andruch,et al.  A novel, environmentally friendly dispersive liquid-liquid microextraction procedure for the determination of copper , 2011 .

[7]  F. Billes,et al.  Application of a bisindocarbocyanine reagent for dispersive liquid–liquid microextraction of silver with subsequent spectrophotometric determination , 2011 .

[8]  Mingli Chen,et al.  New Developments in Flow Injection/Sequential Injection On‐line Separation and Preconcentration Coupled with Electrothermal Atomic Absorption Spectrometry for Trace Metal Analysis , 2007 .

[9]  M. Mori,et al.  Ion-exclusion/cation-exchange chromatographic determination of common inorganic ions in human saliva by using an eluent containing zwitterionic surfactant. , 2008, Journal of Chromatography A.

[10]  J. Posta,et al.  A novel approach in dispersive liquid-liquid microextraction based on the use of an auxiliary solvent for adjustment of density UV-VIS spectrophotometric and graphite furnace atomic absorption spectrometric determination of gold based on ion pair formation. , 2010, Talanta.

[11]  A. Becke Density-functional thermochemistry. III. The role of exact exchange , 1993 .

[12]  Y. Yamini,et al.  A simple and rapid new dispersive liquid-liquid microextraction based on solidification of floating organic drop combined with inductively coupled plasma-optical emission spectrometry for preconcentration and determination of aluminium in water samples. , 2010, Journal of hazardous materials.

[13]  Hian Kee Lee,et al.  Low-density solvent-based solvent demulsification dispersive liquid-liquid microextraction for the fast determination of trace levels of sixteen priority polycyclic aromatic hydrocarbons in environmental water samples. , 2011, Journal of chromatography. A.

[14]  V. Andruch,et al.  A spectrophotometric method for manganese determination in water samples based on ion pair formation and dispersive liquid–liquid microextraction , 2012 .

[15]  Yoshihide Tanaka,et al.  Simultaneous determination of nitrite, nitrate, thiocyanate and uric acid in human saliva by capillary zone electrophoresis and its application to the study of daily variations. , 2004, Journal of chromatography. A.

[16]  Shengqing Li,et al.  Low-density extraction solvent-based solvent terminated dispersive liquid-liquid microextraction combined with gas chromatography-tandem mass spectrometry for the determination of carbamate pesticides in water samples. , 2010, Journal of chromatography. A.

[17]  M. Farajzadeh,et al.  Dispersive liquid-liquid microextraction using extraction solvent lighter than water. , 2009, Journal of separation science.

[18]  N. Kalogerakis,et al.  Developments in single-drop microextraction , 2002 .

[19]  Vasil Andruch,et al.  A dispersive liquid-liquid microextraction procedure for determination of boron in water after ultrasound-assisted conversion to tetrafluoroborate. , 2011, Talanta.

[20]  M. Miró,et al.  Recent Developments in Flow Injection/Sequential Injection Liquid-Liquid Extraction for Atomic Spectrometric Determination of Metals and Metalloids , 2009 .

[21]  Hui Xu,et al.  Analysis of volatile aldehyde biomarkers in human blood by derivatization and dispersive liquid-liquid microextraction based on solidification of floating organic droplet method by high performance liquid chromatography. , 2010, Journal of chromatography. A.