Determination of the herbicide chlorsulfuron by amperometric sensor based on separation-free bienzyme immunoassay

Abstract A separation-free bienzyme immunoassay system has been developed for the electrochemical determination of the herbicide chlorsulfuron. Screen printed electrode with horseradish peroxidase as an integral component of the carbon ink was used as the detector. A membrane with immobilised anti-chlorsulfuron antibodies was attached to the electrode. Free chlorsulfuron in the sample under test and a chlorsulfuron–glucose oxidase conjugate competed for the available binding sites of the membrane-immobilised antibodies. Addition of glucose induced the generation of hydrogen peroxide by the glucose oxidase conjugate, which was in turn reduced by the peroxidase. The latter process caused an electrical current change, due to direct re-reduction of peroxidase by a direct electron transfer mechanism, which was measured to determine the chlorsulfuron content in the sample. Any H 2 O 2 formed in the bulk solution by unbound chlorsulfuron–glucose oxidase conjugate was scavenged by catalase thus removing the need for a washing step. The optimal protocol for chlorsulfuron detection by the method described was found to be: Biodyne A membrane as a carrier, concentration of IgG during adsorption on the membrane—1 ng ml −1 , concentration of the chlorsulfuron–glucose oxidase conjugate—2.5 μg ml −1 (by enzyme), working potential +50 mV versus Ag/AgCl. The total assay time was 15 min. The measuring range for chlorsulfuron detection was 0.01–1 ng ml −1 . The method was suitable application for on-site ecological monitoring.

[1]  J Rishpon,et al.  A one-step, separation-free amperometric enzyme immunosensor. , 1996, Biosensors & bioelectronics.

[2]  M. Meyerhoff,et al.  Novel nonseparation sandwich-type electrochemical enzyme immunoassay system for detecting marker proteins in undiluted blood. , 1995, Clinical chemistry.

[3]  A. Krynitsky Determination of sulfonylurea herbicides in water by capillary electrophoresis and by liquid chromatography/mass spectrometry. , 1997, Journal of AOAC International.

[4]  R. Fields The measurement of amino groups in proteins and peptides. , 1971, The Biochemical journal.

[5]  S. Yoshitake,et al.  Enzyme-labeling of antibodies and their fragments for enzyme immunoassay and immunohistochemical staining. , 1983, Journal of immunoassay.

[6]  A. Habeeb,et al.  Determination of free amino groups in proteins by trinitrobenzenesulfonic acid. , 1966, Analytical biochemistry.

[7]  Powley,et al.  Screening Method for Nine Sulfonylurea Herbicides in Soil and Water by Liquid Chromatography with Ultraviolet Detection. , 1998, Journal of agricultural and food chemistry.

[8]  A Warsinke,et al.  Research and development in biosensors. , 2001, Current opinion in biotechnology.

[9]  Anatoly V. Zherdev,et al.  Development and comparative study of different immunoenzyme techniques for pesticides detection , 1996 .

[10]  J. Rishpon,et al.  Amperometric Enzyme‐channeling Immunosensoe , 1996, Annals of the New York Academy of Sciences.

[11]  C. McNeil,et al.  Specific binding assay for biotin based on enzyme channelling with direct electron transfer electrochemical detection using horseradish peroxidase. , 1995, Biosensors & bioelectronics.

[12]  M D Luque de Castro,et al.  Application of screen-printed electrodes as transducers in affinity flow-through sensor systems. , 1998, Biosensors & bioelectronics.

[13]  C. McNeil,et al.  Separation-free electrochemical immunosensor for rapid determination of atrazine. , 1998, Biosensors & bioelectronics.

[14]  J. Rishpon,et al.  An amperometric enzyme-channeling immunosensor. , 1997, Biosensors & bioelectronics.

[15]  W. Battaglin,et al.  Occurrence of sulfonylurea, sulfonamide, imidazolinone, and other herbicides in rivers, reservoirs and ground water in the Midwestern United States, 1998. , 2000, The Science of the total environment.

[16]  Schuman Sh,et al.  A clinical historical overview of pesticide health issues. , 1997 .

[17]  W. Battaglin,et al.  Routine determination of sulfonylurea, imidazolinone, and sulfonamide herbicides at nanogram-per-liter concentrations by solid-phase extraction and liquid chromatography/mass spectrometry. , 2000, The Science of the total environment.

[18]  B. Hock,et al.  Development of an ELISA for the analysis of atrazine metabolites deethylatrazine and deisopropylatrazine , 1991 .

[19]  A Review of Health-Based Comparative Risk Assessments in the United States , 2000, Reviews on environmental health.

[20]  J Rishpon,et al.  A micro flow injection electrochemical biosensor for organophosphorus pesticides. , 2000, Biosensors & bioelectronics.

[21]  P. Hansen,et al.  New biosensors for environmental analysis. , 1997, EXS.

[22]  H. Yamazaki,et al.  A simple and inexpensive glucose oxidase substrate system for enzyme immunoassay. , 1992, Immunological investigations.

[23]  K Mosbach,et al.  Imprinted polymer-based sensor system for herbicides using differential-pulse voltammetry on screen-printed electrodes. , 1999, Analytical chemistry.

[24]  M. Meyerhoff,et al.  Separation-free sandwich enzyme immunoassays using microporous gold electrodes and self-assembled monolayer/immobilized capture antibodies. , 1994, Analytical chemistry.

[25]  S. T. Toy,et al.  Chlorsulfuron determination in soil extracts by enzyme immunoassay , 1985 .

[26]  C. McNeil,et al.  Amperometric detection of alkaline phosphatase activity at a horseradish peroxidase enzyme electrode based on activated carbon: potential application to electrochemical immunoassay. , 1995, Biosensors & bioelectronics.

[27]  I. Karube,et al.  Biosensors for Environmental Monitoring , 1998, Annals of the New York Academy of Sciences.

[28]  S. Eremin,et al.  Development of Enzyme Immunoassays for the Herbicide Chlorsulfuron , 2004, Applied Biochemistry and Microbiology.