Total variation minimization-based spiral CT reconstruction in a dental panoramic imaging system for cost-effective, low-dose dental X-ray imaging

In the paper, we proposed a pragmatic method capable of implementing a cost-effective, low-dose CT reconstruction directly onto a dental panoramic X-ray imaging system by adopting a spiral source trajectory. In the proposed geometry, a linear-type panoramic imaging sensor is rotated 90° from the orientation for panoramic imaging to imitate fan-beam image acquisition. For image reconstruction, we considered a total variation (TV) minimization-based algorithm that exploited the sparsity of the image gradient and was capable of reconstructing CT images with substantially high image accuracy against the image artifacts from sparse-view data. We implemented the algorithm for the proposed geometry and performed systematic simulation works to demonstrate its feasibility for dental imaging applications. CT images were successfully reconstructed from the proposed geometry, and the reconstruction quality was evaluated quantitatively by using an image similarity metric. We expect the proposed method to be applicable to developing a cost-effective, low-dose, all-in-one dental imaging system.

[1]  E. Sidky,et al.  Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization , 2008, Physics in medicine and biology.

[2]  M. Grass,et al.  3D cone-beam CT reconstruction for circular trajectories. , 2000, Physics in medicine and biology.

[3]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .

[4]  Ruola Ning,et al.  Image-intensifier-based volume tomographic angiography imaging system , 1997, Medical Imaging.

[5]  Jin Sung Kim,et al.  Fast compressed sensing-based CBCT reconstruction using Barzilai-Borwein formulation for application to on-line IGRT. , 2012, Medical physics.

[6]  Emmanuel J. Candès,et al.  Robust uncertainty principles: exact signal reconstruction from highly incomplete frequency information , 2004, IEEE Transactions on Information Theory.

[7]  Kichirou Koshida,et al.  Development of a non-linear weighted hybrid cone-beam CT reconstruction for circular trajectories , 2007, Comput. Medical Imaging Graph..

[8]  R A Kruger,et al.  Computer simulation of image intensifier-based computed tomography detector: vascular application. , 1988, Medical physics.

[9]  Michael W. Vannier,et al.  The effect of pitch in multislice spiral/helical CT , 1999 .

[10]  Lei Zhu,et al.  Compressed sensing based cone-beam computed tomography reconstruction with a first-order methoda). , 2010, Medical physics.

[11]  J. H. Kinsey,et al.  Three-dimensional imaging of heart, lungs, and circulation. , 1980, Science.

[12]  A. Bovik,et al.  A universal image quality index , 2002, IEEE Signal Processing Letters.