Reliability of EMG time-frequency measures of fatigue during repetitive lifting.

PURPOSE To test the short-term and long-term reliability of time-frequency electromyographic (EMG) measures of fatigue during repetitive dynamic lifting and compare it with the reliability of median frequency (MF) EMG measures of fatigue during static lifting. METHODS Fourteen' healthy male subjects (26 +/- 5 years) repetitively (12 lifts/min) lifted and lowered a box (29 x 25 x 23 cm, 13 kg) for 4.5 min during 3 different tests on 2 different days. EMG data and the biomechanics of motion were recorded. Before and after dynamic lifting, static maximum lifting tests were performed. At the end of each of the two sessions, subjects performed a static lift at 80% of their maximum lifting force for 30 s. RESULTS Significant fatigue-related changes were observed during the lifting exercise via EMG time-frequency analysis at the paravertebral L5, L2, T10, and vastus lateralis (VL) electrode sites. Two parameters for assessing fatigue during dynamic contractions [i.e., the Instantaneous Median Frequency (IMDF) and its time dependent change] were shown to be reproducible both in the short-term (2 h) and long-term (2 wk). The corresponding ICCs reflecting the reproducibility of values between sessions were 96.9% (L5), 98.1% (L2), 90.1% (T10), 96.4% (UT), 98.0% (GM), 89.5% (VL), and 99.0% (BF), respectively. For most EMG recording sites, the reliability of the IMDF measures was not dependent upon the postural strategy that the subject used to accomplish the lifting task or on the subject's strength as measured via the static maximum lifting test. A comparison between the ICC values of the IMDF measures and those of the parameters utilized to assess fatigue during static sustained lifts [i.e., the Median Frequency (MDF) and its change during the test] revealed equally good reproducibility for most EMG recording sites. The respective ICC values that took into account time dependent trends for the IMDF parameter were 87.1% (L5), 62.4% (L2), 90.1% (T10), 0% (UT), 72.7% (GM), 45.4% (VL), and 100% (BF), and for the MDF parameter 94.9% (L5), 73.0% (L2), 80.9% (T10), 100% (UT), 89% (GM), 91.7% (VL), and 90.9% (BF), respectively. CONCLUSIONS The time-frequency approach allows one to derive EMG spectral parameters that can be used to monitor muscle fatigue during dynamic real-world tasks such as lifting.

[1]  A V Nargol,et al.  Factors in the reproducibility of electromyographic power spectrum analysis of lumbar paraspinal muscle fatigue. , 1999, Spine.

[2]  G. Wickström,et al.  Reproducibility of nine tests to measure spinal mobility and trunk muscle strength. , 2020, Scandinavian journal of rehabilitation medicine.

[3]  C. D. De Luca,et al.  Control scheme governing concurrently active human motor units during voluntary contractions , 1982, The Journal of physiology.

[4]  M. Knaflitz,et al.  Analysis of myoelectric signals recorded during dynamic contractions , 1996 .

[5]  J. Bartko The Intraclass Correlation Coefficient as a Measure of Reliability , 1966, Psychological reports.

[6]  P. Dolan,et al.  Repetitive lifting tasks fatigue the back muscles and increase the bending moment acting on the lumbar spine. , 1998, Journal of biomechanics.

[7]  G. Borg Psychophysical scaling with applications in physical work and the perception of exertion. , 1990, Scandinavian journal of work, environment & health.

[8]  Serge H. Roy,et al.  Modeling of surface myoelectric signals. II. Model-based signal interpretation , 1999, IEEE Transactions on Biomedical Engineering.

[9]  M Knaflitz,et al.  Time-frequency methods applied to muscle fatigue assessment during dynamic contractions. , 1999, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[10]  L. Oddsson,et al.  Sensory-motor control of the lower back: implications for rehabilitation. , 2001, Medicine and science in sports and exercise.

[11]  C Frigo,et al.  Three-dimensional model for studying the dynamic loads on the spine during lifting. , 1990, Clinical biomechanics.

[12]  Paolo Bonato,et al.  Time-frequency parameters of the surface myoelectric signal for assessing muscle fatigue during cyclic dynamic contractions , 2001, IEEE Transactions on Biomedical Engineering.

[13]  L. Snyder-Mackler,et al.  Comparison of spinal mobility and isometric trunk extensor forces with electromyographic spectral analysis in identifying low back pain. , 1991, Physical therapy.

[14]  Carlo J. De Luca,et al.  The Use of Surface Electromyography in Biomechanics , 1997 .

[15]  P J Sparto,et al.  Wavelet analysis of electromyography for back muscle fatigue detection during isokinetic constant-torque exertions. , 1999, Spine.

[16]  C. D. De Luca,et al.  Development of new protocols and analysis procedures for the assessment of LBP by surface EMG techniques. , 1997, Journal of rehabilitation research and development.

[17]  C J De Luca,et al.  Rank‐ordered regulation of motor units , 1996, Muscle & nerve.

[18]  J R Potvin,et al.  Trunk Muscle Co‐contraction Increases During Fatiguing, Isometric, Lateral Bend Exertions: Possible Implications for Spine Stability , 1998, Spine.

[19]  Bruce Abernethy,et al.  Toward a Quantitative Definition of Manual Lifting Postures , 1997, Hum. Factors.

[20]  P. Bonato,et al.  EMG-based measures of fatigue during a repetitive squat exercise , 2001, IEEE Engineering in Medicine and Biology Magazine.

[21]  C. D. De Luca,et al.  Spectral electromyographic assessment of back muscles in patients with low back pain undergoing rehabilitation. , 1995, Spine.

[22]  P C Matthijsse,et al.  Ankle angle effects on endurance time, median frequency and mean power of gastrocnemius EMG power spectrum: a comparison between individual and group analysis. , 1987, Ergonomics.

[23]  M. Knaflitz,et al.  EMG assessment of back muscle function during cyclical lifting. , 1998, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[24]  P Silventoinen,et al.  Force and EMG power spectrum during eccentric and concentric actions. , 2000, Medicine and science in sports and exercise.

[25]  Carlo J. De Luca Use of the surface EMG signal for performance evaluation of back muscles , 1993 .

[26]  R Merletti,et al.  Indices of muscle fatigue. , 1991, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.