Confidence limits for interpretation of home blood pressure recordings

ObjectiveAccurate and precise estimation of arterial blood pressure is needed for the management of hypertension. Multiple measurements can be obtained from recorded home blood pressures devices. Averages and other statistics can be calculated. Confidence intervals provide an assessment of the precision with which average pressures are measured. This study evaluated confidence intervals for systolic pressure, diastolic pressure, and pulse pressure from recorded home blood pressure measurements. MethodsFifty-three patients with high normal blood pressure, suspected white coat hypertension, or refractory hypertension were assessed by recorded home blood pressure. They were instructed to take four measurements each day for 1 week using a device that stores each measurement. Measurements were downloaded from the device to a computer, stored as data files, and analyzed by software. Average pressures and confidence intervals for each participant were rapidly calculated by standard statistical methods. ResultsThe average width of the 95% confidence intervals for systolic pressure, diastolic pressure, and pulse pressure were 8, 5, and 6 mmHg, respectively with large inter-individual differences. Significant positive correlations were found between the width of the confidence intervals and the average systolic (P<0.05) or pulse pressure (P<0.01). However, the correlation for diastolic pressure was not significant. ConclusionConfidence intervals can be easily calculated for recorded home blood pressures with device storage and may provide a useful approach when cut-off points for classification as normal pressure, high normal pressure, or definite hypertension are to be excluded. This information, combined with knowledge of other risk factors, may help guide decisions for improved management.

[1]  Pierre Corvol,et al.  Self-measurement and self-titration in hypertension: a pilot telemedicine study. , 2007, American journal of hypertension.

[2]  K. Asayama,et al.  Day-by-Day Variability of Blood Pressure and Heart Rate at Home as a Novel Predictor of Prognosis: The Ohasama Study , 2008, Hypertension.

[3]  Daniel W. Jones,et al.  Seventh report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure. , 2003, Hypertension.

[4]  Gilles Chatellier,et al.  Cardiovascular prognosis of "masked hypertension" detected by blood pressure self-measurement in elderly treated hypertensive patients. , 2004, JAMA.

[5]  Lawrence R. Krakoff,et al.  Effect of recorded home blood pressure measurements on the staging of hypertensive patients , 2002, Blood pressure monitoring.

[6]  Alfons G H Kessels,et al.  Home blood pressure measurement: a systematic review. , 2005, Journal of the American College of Cardiology.

[7]  S. Goodman Toward Evidence-Based Medical Statistics. 1: The P Value Fallacy , 1999, Annals of Internal Medicine.

[8]  A. Logan,et al.  Primary-care physicians' views about the use of home/self blood pressure monitoring: nationwide survey in Hungary , 2006, Journal of hypertension.

[9]  R. Collins,et al.  Age-specific relevance of usual blood pressure to vascular mortality: a meta-analysis of individual data for one million adults in 61 prospective studies , 2002, The Lancet.

[10]  M. J. Turner,et al.  Blood pressure variability causes spurious identification of hypertension in clinical studies: a computer simulation study. , 2008, American journal of hypertension.

[11]  Daniel W. Jones,et al.  A Scientific Statement From the American Heart Association Professional Education Committee of the Council for High Blood Pressure Research , 2008 .

[12]  J. Ralston,et al.  Electronic communications and home blood pressure monitoring (e-BP) study: design, delivery, and evaluation framework. , 2008, Contemporary clinical trials.

[13]  G. Parati,et al.  Home blood-pressure monitoring: US and European consensus , 2009, The Lancet.

[14]  Stirling Bryan,et al.  Protocol for a randomised controlled trial of telemonitoring and self-management in the control of hypertension: Telemonitoring and self-management in hypertension. [ISRCTN17585681] , 2009, BMC Cardiovascular Disorders.

[15]  R. Collins,et al.  Underestimation of risk associations due to regression dilution in long-term follow-up of prospective studies. , 1999, American journal of epidemiology.

[16]  W. Elliott Resistant Hypertension: Diagnosis, Evaluation, and Treatment: A Scientific Statement From the American Heart Association Professional Education Committee of the Council for High Blood Pressure Research , 2009 .