Phosphorylation Analysis by Mass Spectrometry

The mass spectrometric analysis of protein phosphorylation is still far from being routine, and the outcomes thereof are often unsatisfying. Apart from the inherent problem of substoichiometric phosphorylation, three arguments as to why phosphorylation analysis is so problematic are often quoted, including (a) increased hydrophilicity of the phosphopeptide with a concomitant loss during the loading onto reversed-phase columns, (b) selective suppression of the ionization of phosphopeptides in the presence of unmodified peptides, and (c) lower ionization/detection efficiencies of phosphopeptides as compared with their unmodified cognates. Here we present the results of a study investigating the validity of these three arguments when using electrospray ionization mass spectrometry. We utilized a set of synthetic peptide/phosphopeptide pairs that were quantitated by amino acid analysis. Under the applied conditions none of the experiments performed supports the notions of (a) generally increased risks of losing phosphopeptides during the loading onto the reversed-phase column because of decreased retention and (b) the selective ionization suppression of phosphopeptides. The issue of ionization/detection efficiencies of phosphopeptides versus their unphosphorylated cognates proved to be less straightforward when using electrospray ionization because no evidence for decreased ionization/detection efficiencies for phosphopeptides could be found.

[1]  M. Posewitz,et al.  Immobilized gallium(III) affinity chromatography of phosphopeptides. , 1999, Analytical chemistry.

[2]  S. Lee,et al.  A strategy for identification and quantitation of phosphopeptides by liquid chromatography/tandem mass spectrometry. , 2000, Analytical biochemistry.

[3]  A. Stensballe,et al.  Characterization of phosphoproteins from electrophoretic gels by nanoscale Fe(III) affinity chromatography with off‐line mass spectrometry analysis , 2001, Proteomics.

[4]  W. Lehmann,et al.  Analysis of protein phosphorylation by a combination of elastase digestion and neutral loss tandem mass spectrometry. , 2001, Analytical chemistry.

[5]  S. Carr,et al.  A multidimensional electrospray MS-based approach to phosphopeptide mapping. , 2001, Analytical chemistry.

[6]  H. Steen,et al.  Quadrupole time-of-flight versus triple-quadrupole mass spectrometry for the determination of phosphopeptides by precursor ion scanning. , 2001, Journal of mass spectrometry : JMS.

[7]  C. Enke,et al.  Predicting electrospray response from chromatographic retention time. , 2001, Analytical chemistry.

[8]  P. Cohen,et al.  The origins of protein phosphorylation , 2002, Nature Cell Biology.

[9]  T. Hunter,et al.  The Protein Kinase Complement of the Human Genome , 2002, Science.

[10]  J. Shabanowitz,et al.  Phosphoproteome analysis by mass spectrometry and its application to Saccharomyces cerevisiae , 2002, Nature Biotechnology.

[11]  I. Chu,et al.  Unique scanning capabilities of a new hybrid linear ion trap mass spectrometer (Q TRAP) used for high sensitivity proteomics applications , 2003, Proteomics.

[12]  P. Cohen CHAPTER 100 – Protein Serine/Threonine Phosphatases and the PPP Family , 2003 .

[13]  H. Gunawardena,et al.  Nanoelectrospray ionization of protein mixtures: solution pH and protein pI. , 2004, Analytical chemistry.

[14]  J. Tavaré,et al.  Identifying protein kinase substrates: hunting for the organ-grinder's monkeys. , 2004, Trends in biochemical sciences.

[15]  Steven P Gygi,et al.  Large-scale characterization of HeLa cell nuclear phosphoproteins. , 2004, Proceedings of the National Academy of Sciences of the United States of America.

[16]  A. Irving,et al.  GSK-3 Phosphorylation of the Alzheimer Epitope within Collapsin Response Mediator Proteins Regulates Axon Elongation in Primary Neurons* , 2004, Journal of Biological Chemistry.

[17]  M. Savitski,et al.  Physicochemical properties determining the detection probability of tryptic peptides in Fourier transform mass spectrometry. A correlation study. , 2004, Analytical chemistry.

[18]  M. Sussman,et al.  An isotope labeling strategy for quantifying the degree of phosphorylation at multiple sites in proteins , 2004, Journal of the American Society for Mass Spectrometry.

[19]  M. Mann,et al.  Tyrosine Phosphoproteomics of Fibroblast Growth Factor Signaling , 2004, Journal of Biological Chemistry.

[20]  M. Kirschner,et al.  Stable isotope-free relative and absolute quantitation of protein phosphorylation stoichiometry by MS. , 2005, Proceedings of the National Academy of Sciences of the United States of America.

[21]  J. Rush,et al.  Immunoaffinity profiling of tyrosine phosphorylation in cancer cells , 2005, Nature Biotechnology.

[22]  Steven P Gygi,et al.  Quantitative phosphorylation profiling of the ERK/p90 ribosomal S6 kinase-signaling cassette and its targets, the tuberous sclerosis tumor suppressors. , 2005, Proceedings of the National Academy of Sciences of the United States of America.

[23]  Iain D G Campuzano,et al.  Proteomic Analysis of in Vivo Phosphorylated Synaptic Proteins* , 2005, Journal of Biological Chemistry.

[24]  L. Brill,et al.  Automated immobilized metal affinity chromatography/nano-liquid chromatography/electrospray ionization mass spectrometry platform for profiling protein phosphorylation sites. , 2005, Rapid communications in mass spectrometry : RCM.

[25]  M. Mann,et al.  Quantitative Phosphoproteomics Applied to the Yeast Pheromone Signaling Pathway*S , 2005, Molecular & Cellular Proteomics.