Feasibility Study of Ground Source Heat Pump System Considering Underground Thermal Properties

: A typical ground source heat pump (GSHP) system in South Korea has a ground heat exchanger (GHX) with a length of 100–150 m, which utilizes annually stable underground temperature to meet the loads of cooling, heating and hot water in buildings. However, most GSHP systems have been introduced in heating dominated areas because the system performance advantage is larger compared with air source heat pump system than that in cooling dominated areas. To effectively provide geothermal energy to the building in the limited urban area, it is necessary to install deep GHXs. Despite its large capacity, there are few studies on GSHP system with deep GHX over 300 m. In this study, to estimate the performance of the GSHP system with deep GHX and evaluate its feasibility, numerical simulation was conducted. To quantitatively analyze heat transfer between soil and GHX, the coupled model with GHX model and ground heat and groundwater transfer model was used. Furthermore, the heat exchange rate and the source temperature were calculated according to the operation modes, the length of GHX, and soil conditions such as geothermal gradient and thermal conductivity. As a result, the total heat exchange rate of GHX with a length of 300 m heat exchanger was 12.62 kW, 173% that of a length of 150 m. Finally, it was found that the GSHP system with deep GHX has realistic possibility in good condition of geothermal gradient.

[1]  Dirk Müller,et al.  Combined simulation of a deep ground source heat exchanger and an office building , 2014 .

[2]  Ryozo Ooka,et al.  Development of a numerical model to predict heat exchange rates for a ground-source heat pump system , 2008 .

[3]  Kyung-soon Park,et al.  Study on Capacity Alteration of Geothermal Heat Exchanger by Changing Design Condition , 2013 .

[4]  Timothy J. Reber,et al.  Geothermal energy characterization in the Appalachian Basin of New York and Pennsylvania , 2015 .

[5]  Yujin Nam,et al.  Numerical Analysis for the Effect of Ground and Groundwater Conditions on the Performance of Ground Source Heat Pump Systems , 2011 .

[6]  Ryuichi Itoi,et al.  Optimizing the design of large-scale ground-coupled heat pump systems using groundwater and heat transport modeling , 2005 .

[7]  José Acuña,et al.  Thermal evaluation of coaxial deep borehole heat exchangers , 2016 .

[8]  J. J. Muñoz-Criollo,et al.  Numerical simulation of ground source heat pump systems considering unsaturated soil properties and groundwater flow , 2018, Applied Thermal Engineering.

[9]  M. Taniguchi,et al.  Shallow subsurface thermal regimes in major plains in Japan with reference to recent surface warming , 2003 .

[10]  Jae-Ho Choi,et al.  Effect of the Design Parameters of Geothermal Heat Exchanger Design Length , 2011 .

[11]  Eui-Jong Kim Impact of Different Boundary Conditions in Generating g-function on the Sizing of Ground Heat Exchangers , 2014 .

[12]  Hanshik Chung,et al.  A Study on the Yearly Measurement and Numerical Analysis of Underground Temperature , 2012 .

[13]  Piljae Im,et al.  Methodology for energy strategy to prescreen the feasibility of Ground Source Heat Pump systems in residential and commercial buildings in the United States , 2017 .

[14]  Jinfeng Mao,et al.  Heat transfer analysis of a vertical ground heat exchanger using numerical simulation and multiple regression model , 2016 .

[15]  A. Dupuy,et al.  Thermal performance of a deep borehole heat exchanger: Insights from a synthetic coupled heat and flow model , 2015 .

[16]  Yong Wang,et al.  Study on Heat Transfer Calculation Method of Ground Heat Exchangers Based on Heat Pump Unit Operation Characteristics , 2016 .

[17]  Pirjo Majuri,et al.  Technologies and environmental impacts of ground heat exchangers in Finland , 2017 .

[18]  Α. Michopoulos,et al.  Predicting the fluid temperature at the exit of the vertical ground heat exchangers , 2009 .