The electrical resistance response of continuous carbon fibre composite laminates to mechanical strain

Abstract Measurements have been made of the effect of mechanical strain on potential distributions and resistance of unidirectional and multidirectional carbon fibre epoxy laminates. The effects of current flow direction and technique for current introduction on piezo-resistance have been studied. It was found that uniform current introduction at sample edges produced by sputtered Au–Cr contacts across the entire cross-section produced consistently low values of gauge factor of 1.75 for current flow parallel to the fibres and 2.7 for transverse current flow. Non-uniform current introduction, produced variously by local point introduction of current, or use of viscous adhesives producing intermittent contact, resulted in a wide range of apparent gauge factors ranging from 20.6 to −89. These anomalous values may be explained by a model in which the high anisotropy of resistance in unidirectional CFRP maintains initial non-uniform current throughout the sample. Under mechanical strain points of fibre contact will change, altering the distribution of current carrying fibres and leading to local changes in current. Thus changes in potential difference between two points produced by mechanical strain will not be exclusively caused by changes in local resistance. The presence of transverse plies in multidirectional laminates ensures that in plane non-uniform current distributions are largely eliminated, and the effect on piezo-resistance of non-uniform current introduction is minimised.

[1]  Jae Whan Cho,et al.  Relationship between electrical resistance and strain of carbon fibers upon loading , 2000 .

[2]  Karl Schulte,et al.  Non-destructive testing of FRP by d.c. and a.c. electrical methods , 2001 .

[3]  N. Khemiri,et al.  Damage detection in CFRP laminates using electrical potential techniques , 2003, SPIE Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring.

[4]  Akira Todoroki,et al.  Measurement of orthotropic electric conductance of CFRP laminates and analysis of the effect on delamination monitoring with an electric resistance change method , 2002 .

[5]  C. Bakis,et al.  Self-monitoring, pseudo-ductile, hybrid FRP reinforcement rods for concrete applications , 2001 .

[6]  Nobuo Takeda,et al.  Electromechanical modeling of unidirectional CFRP composites under tensile loading condition , 2002 .

[7]  D. Chung,et al.  Temperature/light sensing using carbon fiber polymer-matrix composite , 1999 .

[8]  Xiaojun Wang,et al.  Sensing delamination in a carbon fiber polymer-matrix composite during fatigue by electrical resistance measurement , 1997 .

[9]  Simon A. Hayes,et al.  A resistance-based damage location sensor for carbon-fibre composites , 2002 .

[10]  Phil E. Irving,et al.  Fatigue damage characterization in carbon fibre composite materials using an electrical potential technique , 1998 .

[11]  A. Chateauminois,et al.  In situ detection of damage in CFRP laminates by electrical resistance measurements , 1999 .

[12]  S. Al-Hassani,et al.  ELECTRICAL RESISTANCE MEASUREMENT TECHNIQUE FOR DETECTING FAILURE IN CFRP MATERIALS AT HIGH STRAIN RATES , 1994 .

[13]  Akira Todoroki,et al.  High performance estimations of delamination of graphite/epoxy laminates with electric resistance change method , 2003 .

[14]  Kazumasa Moriya,et al.  A study on flaw detection method for CFRP composite laminates. (1st report). The measurement of crack extension in CFRP composites by electrical potential method. , 1988 .

[15]  D.D.L. Chung,et al.  Self-monitoring of fatigue damage and dynamic strain in carbon fiber polymer-matrix composite , 1998 .

[16]  C. Owston,et al.  Electrical properties of single carbon fibres , 1970 .

[17]  Akira Todoroki,et al.  The effect of number of electrodes and diagnostic tool for monitoring the delamination of CFRP laminates by changes in electrical resistance , 2001 .

[18]  Shiv P. Joshi,et al.  An experimental investigation of through-thickness electrical resistivity of CFRP laminates , 2001 .

[19]  R. Prabhakaran,et al.  Damage assessment through electrical resistance measurement in graphite fiber-reinforced composites , 1990 .