Chapter 36 - Absolute Cerebral Blood Flow with [ 15 O]Water and PET: Determination Without a Measured Input Function

This chapter presents a method to measure absolute cerebral blood flow cerebral blood flow (CBF) following a bolus injection using only dynamic tissue radioactivity values derived from reconstructed image data. As in all CBF methods, the input function is assumed to be common to all brain pixels. Each pixel's time–activity curve therefore has information about the local blood flow and the input function. By analyzing all pixels simultaneously, the input function can be estimated. Further, the theory and implementation of the new method and present results from simulated data and human studies are described. The Gauss–Newton (GN) method can produce accurate CBF measurements only when the measurements follow the assumed model. Tissue heterogeneity and other factors produce large bias in the GN flow values. These model errors produce much smaller biases in other algorithms that use a measured input function. By estimating both flow and the input function, the GN algorithm has more flexibility in minimizing Ψ and, therefore, is more sensitive to model errors. Two modified methods presented reduced the global flow bias, but eliminated the positive correlation of GN results with those using the measured input functions. Therefore, a better model for the distribution volume is required for the GN approach to produce accurate and reliable human CBF data.

[1]  F. Shishido,et al.  Evaluation of Regional Differences of Tracer Appearance Time in Cerebral Tissues Using [15O]Water and Dynamic Positron Emission Tomography , 1988, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[2]  James V. Beck,et al.  Parameter Estimation in Engineering and Science , 1977 .

[3]  F. Miraldi,et al.  Noninvasive arterial monitor for quantitative oxygen-15-water blood flow studies. , 1993, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[4]  J. Mazziotta,et al.  A Noninvasive Positron Computed Tomography Technique Using Oxygen-15-Labeled Water for the Evaluation of Neurobehavioral Task Batteries , 1985, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[5]  Richard Coppola,et al.  Physiological activation of a cortical network during performance of the Wisconsin Card Sorting Test: A positron emission tomography study , 1995, Neuropsychologia.

[6]  Richard E. Carson,et al.  Precision and accuracy of regional radioactivity quantitation using the maximum likelihood EM reconstruction algorithm , 1994, IEEE Trans. Medical Imaging.

[7]  R E Carson,et al.  Precision and Accuracy Considerations of Physiological Quantitation in PET , 1991, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[8]  M. Raichle,et al.  Brain blood flow measured with intravenous H2(15)O. I. Theory and error analysis. , 1983, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[9]  I Kanno,et al.  A Determination of the Regional Brain/Blood Partition Coefficient of Water Using Dynamic Positron Emission Tomography , 1989, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[10]  R. Frackowiak,et al.  Quantitative Measurement of Regional Cerebral Blood Flow and Oxygen Metabolism in Man Using 15O and Positron Emission Tomography: Theory, Procedure, and Normal Values , 1980, Journal of computer assisted tomography.

[11]  M E Phelps,et al.  Measurement of Local Blood Flow and Distribution Volume with Short-Lived Isotopes: A General Input Technique , 1982, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[12]  J. Holden,et al.  Quantitation of Local Cerebral Blood Flow and Partition Coefficient without Arterial Sampling: Theory and Validation , 1985, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[13]  M. Mintun,et al.  A Noninvasive Approach to Quantitative Functional Brain Mapping with H215O and Positron Emission Tomography , 1984, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[14]  Peter Herscovitch,et al.  An approximation formula for the variance of PET region-of-interest values , 1993, IEEE Trans. Medical Imaging.

[15]  R A Koeppe,et al.  Performance Comparison of Parameter Estimation Techniques for the Quantitation of Local Cerebral Blood Flow by Dynamic Positron Computed Tomography , 1985, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[16]  J E Holden,et al.  Cerebral blood flow using PET measurements of fluoromethane kinetics. , 1981, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[17]  G. L. Brownell,et al.  Estimation of the Local Statistical Noise in Emission Computed Tomography , 1982, IEEE Transactions on Medical Imaging.