Quantitative assessment of conjunctival microvascular circulation of the human eye.

Accessibility to the bulbar conjunctival microvasculature provides a means to assess blood supply to the cerebral cortex and thus optimize therapeutic interventions designed to prevent or reduce the risk of cerebral vascular disease and stroke. The feasibility of a method for quantitative measurements of conjunctiva blood vessel diameter, blood velocity, and flow in the human eye is reported. The method is based on slit lamp biomicroscope digital imaging coupled with a space time image analysis technique. A sequence of conjunctiva microvasculature images was captured at a rate of 50 Hz. The images were analyzed to determine blood vessel diameter, velocity and flow. Blood vessel diameter measurements ranged between 8.7 and 24.3 microns, with a mean value of 15.5 microns. Blood flow rate ranged between 27.3 and 296.9 pl/s, with a mean value of 111.8 pl/s. The relationship between blood flow and vessel diameter was fit with a power law curve (R=0.87). The application of this technique for in vivo quantitative assessment of blood flow dynamics has potential to impact diagnosis and monitoring of various cardiovascular and blood disorders.

[1]  L. Jones,et al.  Assessment of Variation in Bulbar Conjunctival Redness, Temperature, and Blood Flow , 2007, Optometry and vision science : official publication of the American Academy of Optometry.

[2]  Peter C Y Chen,et al.  Microvascular abnormalities in sickle cell disease: a computer-assisted intravital microscopy study. , 2002, Blood.

[3]  Christopher G Ellis,et al.  Automated Method for Tracking Individual Red Blood Cells Within Capillaries to Compute Velocity and Oxygen Saturation , 2005, Microcirculation.

[4]  K. Schaser,et al.  Noninvasive analysis of conjunctival microcirculation during carotid artery surgery reveals microvascular evidence of collateral compensation and stenosis-dependent adaptation. , 2003, Journal of vascular surgery.

[5]  R. Adams,et al.  Correlation of abnormal intracranial vessel velocity, measured by transcranial Doppler ultrasonography, with abnormal conjunctival vessel velocity, measured by computer-assisted intravital microscopy, in sickle cell disease. , 2001, Blood.

[6]  A. Gruen ADAPTIVE LEAST SQUARES CORRELATION: A POWERFUL IMAGE MATCHING TECHNIQUE , 1985 .

[7]  N. Mohandas,et al.  In vivo blood flow abnormalities in the transgenic knockout sickle cell mouse. , 1999, The Journal of clinical investigation.

[8]  A. Koutsiaris,et al.  Volume flow and wall shear stress quantification in the human conjunctival capillaries and post-capillary venules in vivo. , 2007, Biorheology.

[9]  Christopher G Ellis,et al.  A New Video Image Analysis System to Study Red Blood Cell Dynamics and Oxygenation in Capillary Networks , 2005, Microcirculation.

[10]  C G Ellis,et al.  Application of image analysis for evaluation of red blood cell dynamics in capillaries. , 1992, Microvascular research.

[11]  Ian J. Deary,et al.  Retinal image analysis: concepts, applications and potential , 2006 .