The Use of Cone Beam Computed Tomography for Image Guided Gamma Knife Stereotactic Radiosurgery: Initial Clinical Evaluation.

PURPOSE The present study used cone beam computed tomography (CBCT) to measure the inter- and intrafraction uncertainties for intracranial stereotactic radiosurgery (SRS) using the Leksell Gamma Knife (GK). METHODS AND MATERIALS Using a novel CBCT system adapted to the GK radiosurgery treatment unit, CBCT images were acquired immediately before and after treatment for each treatment session within the context of a research ethics board-approved prospective clinical trial. Patients were immobilized in the Leksell coordinate frame (LCF) for both volumetric CBCT imaging and GK-SRS delivery. The relative displacement of the patient's skull to the stereotactic reference (interfraction motion) was measured for each CBCT scan. Differences between the pre- and post-treatment CBCT scans were used to determine the intrafraction motion. RESULTS We analyzed 20 pre- and 17 post-treatment CBCT scans in 20 LCF patients treated with SRS. The mean translational pretreatment setup error ± standard deviation in the left-right, anteroposterior, and craniocaudal directions was -0.19 ± 0.32, 0.06 ± 0.27, and -0.23 ± 0.2 mm, with a maximum of -0.74, -0.53, and -0.68 mm, respectively. After an average time between the pre- and post-treatment CBCT scans of 82 minutes (range 27-170), the mean intrafraction error ± standard deviation for the LCF was -0.03 ± 0.05, -0.03 ± 0.18, and -0.03 ± 0.12 mm in the left-right, anteroposterior, and craniocaudual direction, respectively. CONCLUSIONS Using CBCT on a prototype image guided GK Perfexion unit, we were able to measure the inter- and intrafraction positional changes for GK-SRS using the invasive frame. In the era of image guided radiation therapy, the use of CBCT image guidance for both frame- and non-frame-based immobilization systems could serve as a useful quality assurance tool. Our preliminary measurements can guide the application of achievable thresholds for inter- and intrafraction discrepancy when moving to a frameless approach.

[1]  Verhey,et al.  The Physics of Radiosurgery. , 1995, Seminars in radiation oncology.

[2]  Winnie Li Determining Rational Planning Target Volume Margins for Intracranial Stereotactic Radiotherapy , 2014 .

[3]  M. V. van Herk,et al.  The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapy. , 2000, International journal of radiation oncology, biology, physics.

[4]  S. Goyal,et al.  Frame-based radiosurgery: Is it relevant in the era of IGRT? , 2013, Neurology India.

[5]  Ravindra Yaparpalvi,et al.  Clinical experiences with onboard imager KV images for linear accelerator-based stereotactic radiosurgery and radiotherapy setup. , 2009, International journal of radiation oncology, biology, physics.

[6]  David A Jaffray,et al.  Emergent technologies for 3-dimensional image-guided radiation delivery. , 2005, Seminars in radiation oncology.

[7]  M. Mehta,et al.  A cost-effectiveness and cost-utility analysis of radiosurgery vs. resection for single-brain metastases. , 1997, International journal of radiation oncology, biology, physics.

[8]  P. Cornu,et al.  Radiosurgery for brain metastasis: impact of CTV on local control. , 2003, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[9]  L. Leksell The stereotaxic method and radiosurgery of the brain. , 1951, Acta chirurgica Scandinavica.

[10]  David A Jaffray,et al.  Geometric Performance and Efficiency of an Optical Tracking System for Daily Pre-treatment Positioning in Pelvic Radiotherapy Patients , 2011, Technology in cancer research & treatment.

[11]  M. McDermott,et al.  Impact of millimeter-level margins on peripheral normal brain sparing for gamma knife radiosurgery. , 2014, International journal of radiation oncology, biology, physics.

[12]  Martin J Murphy,et al.  Intrafraction geometric uncertainties in frameless image-guided radiosurgery. , 2009, International journal of radiation oncology, biology, physics.

[13]  David J Brenner,et al.  The tumor radiobiology of SRS and SBRT: are more than the 5 Rs involved? , 2014, International journal of radiation oncology, biology, physics.

[14]  Kimia Ghobadi,et al.  Automated treatment planning for a dedicated multi-source intra-cranial radiosurgery treatment unit accounting for overlapping structures and dose homogeneity. , 2013, Medical physics.

[15]  Steven D Chang,et al.  Clinical Investigation : Central Nervous System Tumor Stereotactic Radiosurgery of the Postoperative Resection Cavity for Brain Metastases : Prospective Evaluation of Target Margin on Tumor Control , 2022 .

[16]  Matthias Guckenberger,et al.  Reliability of the bony anatomy in image-guided stereotactic radiotherapy of brain metastases. , 2007, International journal of radiation oncology, biology, physics.

[17]  Adam P Dicker,et al.  Radiation dose-volume effects in the brain. , 2010, International journal of radiation oncology, biology, physics.

[18]  Naren Ramakrishna,et al.  A clinical comparison of patient setup and intra-fraction motion using frame-based radiosurgery versus a frameless image-guided radiosurgery system for intracranial lesions. , 2010, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[19]  R. Maciunas,et al.  12 Gy gamma knife radiosurgical volume is a predictor for radiation necrosis in non-AVM intracranial tumors. , 2006, International journal of radiation oncology, biology, physics.

[20]  Philip T. Komljenovic,et al.  Cone beam computed tomography image guidance system for a dedicated intracranial radiosurgery treatment unit. , 2013, International journal of radiation oncology, biology, physics.

[21]  E. Touboul,et al.  Radiosurgery with or without A 2-mm margin for 93 single brain metastases. , 2008, International journal of radiation oncology, biology, physics.

[22]  B. Fallone,et al.  Frame slippage verification in stereotactic radiosurgery. , 1998, International journal of radiation oncology, biology, physics.

[23]  R. Maciunas,et al.  The application accuracy of stereotactic frames. , 1994, Neurosurgery.