Linear Quadratic Gaussian-Based Closed-Loop Control of Type 1 Diabetes

Background: We investigated the applicability of linear quadratic Gaussian (LQG) methodology to the subcutaneous blood glucose regulation problem. We designed an LQG-based feedback control algorithm using linearization of a previously published metabolic model of type 1 diabetes. A key feature of the controller is a Kalman filter used to estimate metabolic states of the patient based on continuous glucose monitoring. Insulin infusion is computed from linear quadratic regulator feedback gains applied to these estimates, generally seeking to minimize squared deviations from a target glucose concentration and basal insulin rate. We evaluated in silico subject-specific LQG control and compared it to preexisting proportional-integral-derivative control.

[1]  E. Kraegen,et al.  Control of blood glucose in diabetics using an artificial pancreas. , 1977, Australian and New Zealand journal of medicine.

[2]  B. Bequette A critical assessment of algorithms and challenges in the development of a closed-loop artificial pancreas. , 2005, Diabetes technology & therapeutics.

[3]  W. Schenk,et al.  Does Physiological Blood Glucose Control Require an Adaptive Control Strategy? , 1987, IEEE Transactions on Biomedical Engineering.

[4]  R. Ollerton Application of optimal control theory to diabetes mellitus , 1989 .

[5]  D. Cox,et al.  Symmetrization of the Blood Glucose Measurement Scale and Its Applications , 1997, Diabetes Care.

[6]  R.S. Parker,et al.  A model-based algorithm for blood glucose control in Type I diabetic patients , 1999, IEEE Transactions on Biomedical Engineering.

[7]  A H Clemens,et al.  The artificial beta cell--a continuous control of blood sugar by external regulation of insulin infusion (glucose controlled insulin infusion system). , 1974, Hormone and metabolic research = Hormon- und Stoffwechselforschung = Hormones et metabolisme.

[8]  T. Yoneyama,et al.  A robust controller for insulin pumps based on H-infinity theory , 1993, IEEE Transactions on Biomedical Engineering.

[9]  B. Anderson,et al.  Optimal control: linear quadratic methods , 1990 .

[10]  R. Hovorka Continuous glucose monitoring and closed‐loop systems , 2006, Diabetic medicine : a journal of the British Diabetic Association.

[11]  W. Zingg,et al.  An Artificial Endocrine Pancreas , 1974, Diabetes.

[12]  K. Teo,et al.  Optimal insulin infusion resulting from a mathematical model of blood glucose dynamics , 1989, IEEE Transactions on Biomedical Engineering.

[13]  James H Nichols,et al.  Performance evaluation of blood glucose monitoring devices. , 2003, Diabetes technology & therapeutics.

[14]  J. Robert,et al.  Glycemic Control with Closed-Loop Intraperitoneal Insulin in Type I Diabetes , 1986, Diabetes Care.

[15]  G. Nicolao,et al.  Model Predictive Control of glucose concentration in subjects with type 1 diabetes: an in silico trial , 2008 .

[16]  B. Zinman,et al.  Normalization of Glycemia in Diabetics During Meals with Insulin and Glucagon Delivery by the Artificial Pancreas , 1977, Diabetes.

[17]  U. Fischer,et al.  Kinetic Modeling of the Glucoregulatory System to Improve Insulin Therapy , 1985, IEEE Transactions on Biomedical Engineering.

[18]  F. Hariri,et al.  Interstitial fluid glucose dynamics during insulin-induced hypoglycaemia , 2005, Diabetologia.

[19]  R. Hovorka,et al.  Nonlinear model predictive control of glucose concentration in subjects with type 1 diabetes. , 2004, Physiological measurement.

[20]  Philip J Stout,et al.  A novel approach to mitigating the physiological lag between blood and interstitial fluid glucose measurements. , 2004, Diabetes technology & therapeutics.

[21]  John Thomas Sorensen,et al.  A physiologic model of glucose metabolism in man and its use to design and assess improved insulin therapies for diabetes , 1985 .

[22]  Claudio Cobelli,et al.  GIM, Simulation Software of Meal Glucose—Insulin Model , 2007, Journal of diabetes science and technology.

[23]  D. Cox,et al.  Evaluating the accuracy of continuous glucose-monitoring sensors: continuous glucose-error grid analysis illustrated by TheraSense Freestyle Navigator data. , 2004, Diabetes care.

[24]  I. Deary,et al.  A Structural Equation Model for Predictors of Severe Hypoglycaemia in Patients with Insulin‐dependent Diabetes Mellitus , 1997 .

[25]  U. Fischer,et al.  Derivation and experimental proof of a new algorithm for the artificial B-cell based on the individual analysis of the physiological insulin-glucose relationship. , 1978, Endokrinologie.

[26]  G. W. Swan An optimal control model of diabetes mellitus , 1982 .

[27]  D. Nathan,et al.  Clinical Trial of Programmable Implantable Insulin Pump For Type I Diabetes , 1992, Diabetes Care.

[28]  F. El-Khatib,et al.  Adaptive Closed-Loop Control Provides Blood-Glucose Regulation Using Dual Subcutaneous Insulin and Glucagon Infusion in Diabetic Swine , 2007, Journal of diabetes science and technology.

[29]  D. B. Ridgely,et al.  Control of an artificial human pancreas using the SDRE method , 1997, Proceedings of the 1997 American Control Conference (Cat. No.97CH36041).

[30]  G. Steil,et al.  Feasibility of Automating Insulin Delivery for the Treatment of Type 1 Diabetes , 2006, Diabetes.

[31]  R. Potts,et al.  Physiological differences between interstitial glucose and blood glucose measured in human subjects. , 2003, Diabetes care.

[32]  A. M. Albisser,et al.  Comparison of Algorithms for the Closed-Loop Control of Blood Glucose Using the Artificial Beta Cell , 1981, IEEE Transactions on Biomedical Engineering.

[33]  Eric Renard,et al.  Implantable closed-loop glucose-sensing and insulin delivery: the future for insulin pump therapy. , 2002, Current opinion in pharmacology.

[34]  Y. Z. Ider,et al.  Quantitative estimation of insulin sensitivity. , 1979, The American journal of physiology.

[35]  C. Saudek,et al.  Timing of changes in interstitial and venous blood glucose measured with a continuous subcutaneous glucose sensor. , 2003, Diabetes.

[36]  D. Cox,et al.  Evaluating Clinical Accuracy of Systems for Self-Monitoring of Blood Glucose , 1987, Diabetes Care.

[37]  Clemens Ah,et al.  Feedback control dynamics for glucose controlled insulin infusion system. , 1979 .

[38]  Boris Kovatchev,et al.  Evaluating the clinical accuracy of two continuous glucose sensors using continuous glucose-error grid analysis. , 2005, Diabetes care.

[39]  P. Cryer Hypoglycemia is the limiting factor in the management of diabetes , 1999, Diabetes/metabolism research and reviews.

[40]  David Kerr,et al.  Performance of a continuous glucose monitoring system during controlled hypoglycaemia in healthy volunteers. , 2002, Diabetes technology & therapeutics.

[41]  M. Fisher,et al.  A semiclosed-loop algorithm for the control of blood glucose levels in diabetics , 1991, IEEE Transactions on Biomedical Engineering.

[42]  Claudio Cobelli,et al.  Meal Simulation Model of the Glucose-Insulin System , 2007, IEEE Transactions on Biomedical Engineering.