Optimizing a Sensor Network with Data from Hazard Mapping Demonstrated in a Heavy-Vehicle Manufacturing Facility

Objectives To design a method that uses preliminary hazard mapping data to optimize the number and location of sensors within a network for a long-term assessment of occupational concentrations, while preserving temporal variability, accuracy, and precision of predicted hazards. Methods Particle number concentrations (PNCs) and respirable mass concentrations (RMCs) were measured with direct-reading instruments in a large heavy-vehicle manufacturing facility at 80-82 locations during 7 mapping events, stratified by day and season. Using kriged hazard mapping, a statistical approach identified optimal orders for removing locations to capture temporal variability and high prediction precision of PNC and RMC concentrations. We compared optimal-removal, random-removal, and least-optimal-removal orders to bound prediction performance. Results The temporal variability of PNC was found to be higher than RMC with low correlation between the two particulate metrics (ρ = 0.30). Optimal-removal orders resulted in more accurate PNC kriged estimates (root mean square error [RMSE] = 49.2) at sample locations compared with random-removal order (RMSE = 55.7). For estimates at locations having concentrations in the upper 10th percentile, the optimal-removal order preserved average estimated concentrations better than random- or least-optimal-removal orders (P < 0.01). However, estimated average concentrations using an optimal-removal were not statistically different than random-removal when averaged over the entire facility. No statistical difference was observed for optimal- and random-removal methods for RMCs that were less variable in time and space than PNCs. Conclusions Optimized removal performed better than random-removal in preserving high temporal variability and accuracy of hazard map for PNC, but not for the more spatially homogeneous RMC. These results can be used to reduce the number of locations used in a network of static sensors for long-term monitoring of hazards in the workplace, without sacrificing prediction performance.

[1]  P. O’Shaughnessy,et al.  Distribution of particle and gas concentrations in Swine gestation confined animal feeding operations. , 2012, The Annals of occupational hygiene.

[2]  Kirsten A Koehler,et al.  Influence of analysis methods on interpretation of hazard maps. , 2013, The Annals of occupational hygiene.

[3]  Jun Zhu,et al.  Effects of Data Sparsity and Spatiotemporal Variability on Hazard Maps of Workplace Noise , 2015, Journal of occupational and environmental hygiene.

[4]  William A Heitbrink,et al.  Characterization and Mapping of Very Fine Particles in an Engine Machining and Assembly Facility , 2007, Journal of occupational and environmental hygiene.

[5]  J. W. van Groenigen,et al.  The influence of variogram parameters on optimal sampling schemes for mapping by kriging , 2000 .

[6]  Gerard B. M. Heuvelink,et al.  Sampling desigh optimization for space-time kriging , 2012 .

[7]  Chang-Chuan Chan,et al.  Sampling strategies for occupational exposure assessment under generalized linear model. , 2009, The Annals of occupational hygiene.

[8]  John Volckens,et al.  Prospects and pitfalls of occupational hazard mapping: 'between these lines there be dragons'. , 2011, The Annals of occupational hygiene.

[9]  J. Bottenheim,et al.  Five years of continuous observations of PAN and ozone at a rural location in eastern Canada , 1994 .

[10]  Naresh Kumar,et al.  An Optimal Spatial Sampling Design for Intra-Urban Population Exposure Assessment. , 2009, Atmospheric environment.

[11]  Pavlos S. Kanaroglou,et al.  Establishing an air pollution monitoring network for intra-urban population exposure assessment: A location-allocation approach , 2005 .

[12]  S. Katharine Hammond,et al.  Mapping Particulate Matter at the Body Weld Department in an Automobile Assembly Plant , 2010, Journal of occupational and environmental hygiene.

[13]  P. Diggle,et al.  Model‐based geostatistics , 2007 .

[14]  Guangqing Chi,et al.  Applied Spatial Data Analysis with R , 2015 .

[15]  L. Waller,et al.  Applied Spatial Statistics for Public Health Data: Waller/Applied Spatial Statistics , 2004 .

[16]  G. Heuvelink,et al.  Optimization of sample patterns for universal kriging of environmental variables , 2007 .

[17]  Noel A Cressie,et al.  Statistics for Spatial Data. , 1992 .

[18]  Dennis M O'Brien,et al.  Aerosol mapping of a facility with multiple cases of hypersensitivity pneumonitis: demonstration of mist reduction and a possible dose/response relationship. , 2003, Applied occupational and environmental hygiene.

[19]  William A Heitbrink,et al.  The mapping of fine and ultrafine particle concentrations in an engine machining and assembly facility. , 2006, The Annals of occupational hygiene.

[20]  William A Heitbrink,et al.  Ultrafine and respirable particles in an automotive grey iron foundry. , 2007, The Annals of occupational hygiene.

[21]  Edzer J. Pebesma,et al.  Multivariable geostatistics in S: the gstat package , 2004, Comput. Geosci..

[22]  Jean Dasch,et al.  Characterization of Fine Particles from Machining in Automotive Plants , 2005, Journal of occupational and environmental hygiene.

[23]  Ji Young Park,et al.  Determination of Particle Concentration Rankings by Spatial Mapping of Particle Surface Area, Number, and Mass Concentrations in a Restaurant and a Die Casting Plant , 2010, Journal of occupational and environmental hygiene.

[24]  Mike Rees,et al.  5. Statistics for Spatial Data , 1993 .

[25]  P. Diggle Applied Spatial Statistics for Public Health Data , 2005 .

[26]  Edzer Pebesma,et al.  Mapping of background air pollution at a fine spatial scale across the European Union. , 2009, The Science of the total environment.

[28]  M. Brauer,et al.  Spatial Modeling for Air Pollution Monitoring Network Design: Example of Residential Woodsmoke , 2007, Journal of the Air & Waste Management Association.

[29]  Gerard B. M. Heuvelink,et al.  Optimization of mobile radioactivity monitoring networks , 2010, Int. J. Geogr. Inf. Sci..

[30]  R. Vincent,et al.  Assessment of occupational exposure to chemicals by air sampling for comparison with limit values: the influence of sampling strategy. , 2014, The Annals of occupational hygiene.