Multispectral in vivo three-dimensional optical coherence tomography of human skin.

The capability of optical coherence tomography (OCT) to perform "optical biopsy" of tissues within a depth range of 1 to 2 mm with micron-scale resolution in real time makes it a promising biomedical imaging modality for dermatologic applications. Three high-speed, spectrometer-based frequency-domain OCT systems operating at 800 nm (20,000 A-scans/s), 1060 nm, and 1300 nm (both 47,000 A-scans/s) at comparable signal-to-noise ratio (SNR), SNR roll-off with scanning depth, and transverse resolution (<15 microm) were used to acquire 3-D tomograms of glabrous and hairy human skin in vivo. Images obtained using these three systems were compared in terms of penetration depth, resolution, and contrast. Normal as well as abnormal sites like moles and scar tissue were examined. In this preliminary study, skin pigmentation had little effect on penetration accomplished at three different wavelengths. The epidermis and dermal-epidermal junction could be properly delineated using OCT at 800 nm, and this wavelength offered better contrast over the other two wavelength regions. OCT at 1300 nm permits imaging of deeper dermal layers, critical for detecting deeper tumor boundaries and other deeper skin pathologies. The performance at 1060 nm compromises between the other wavelengths in terms of penetration depth and image contrast.

[1]  R. Caplan,et al.  Skin , 1961, Your Baby's First Year.

[2]  Bruce J Tromberg,et al.  Imaging wound healing using optical coherence tomography and multiphoton microscopy in an in vitro skin-equivalent tissue model. , 2004, Journal of biomedical optics.

[3]  Milind Rajadhyaksha,et al.  Skin imaging with reflectance confocal microscopy. , 2008, Seminars in cutaneous medicine and surgery.

[4]  Eva Lankenau,et al.  OCT in Dermatology , 2008 .

[5]  B. Querleux,et al.  In vivo high-resolution MR imaging of the skin in a whole-body system at 1.5 T. , 1990, Radiology.

[6]  W. Sterry,et al.  Successful treatment of multiple actinic keratoses in organ transplant patients with topical 5% imiquimod: a report of six cases , 2006, The British journal of dermatology.

[7]  Helmut H. Wolff,et al.  Optical coherence tomography in contact dermatitis and psoriasis , 2003, Archives of Dermatological Research.

[8]  Thilo Gambichler,et al.  Characterization of benign and malignant melanocytic skin lesions using optical coherence tomography in vivo. , 2007, Journal of the American Academy of Dermatology.

[9]  J. Fujimoto,et al.  Optical coherence tomography: technology and applications , 2002, IEEE/LEOS International Conference on Optical MEMs.

[10]  M. Pierce,et al.  Polarization-sensitive optical coherence tomography of invasive basal cell carcinoma. , 2004, Journal of biomedical optics.

[11]  J. Schmitt,et al.  Correlation of Thickness of Basal Cell Carcinoma by Optical Coherence Tomography In Vivo and Routine Histologic Findings: A Pilot Study , 2007, Dermatologic surgery : official publication for American Society for Dermatologic Surgery [et al.].

[12]  B. Bouma,et al.  Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography. , 2003, Optics letters.

[13]  J. Fujimoto,et al.  Optical Coherence Tomography , 1991 .

[14]  Stefan Kray,et al.  Simultaneous dual-band ultra-high resolution optical coherence tomography. , 2007, Optics express.

[15]  Thilo Gambichler,et al.  Applications of optical coherence tomography in dermatology. , 2005, Journal of dermatological science.

[16]  Vrushali R. Korde,et al.  Using optical coherence tomography to evaluate skin sun damage and precancer , 2007, Lasers in surgery and medicine.

[17]  K Wolff,et al.  Improvement of the diagnostic accuracy in pigmented skin lesions by epiluminescent light microscopy. , 1987, Anticancer research.

[18]  J. Fujimoto,et al.  In vivo ultrahigh-resolution optical coherence tomography. , 1999, Optics letters.

[19]  Bernard Querleux,et al.  Skin from various ethnic origins and aging: an in vivo cross‐sectional multimodality imaging study , 2009, Skin research and technology : official journal of International Society for Bioengineering and the Skin (ISBS) [and] International Society for Digital Imaging of Skin (ISDIS) [and] International Society for Skin Imaging.

[20]  Barry Cense,et al.  Advances in optical coherence tomography imaging for dermatology. , 2004, The Journal of investigative dermatology.

[21]  M. Jeanmougin SOLEIL ET PEAU , 1992 .

[22]  H. Wulf,et al.  Epidermal thickness at different body sites: relationship to age, gender, pigmentation, blood content, skin type and smoking habits. , 2003, Acta dermato-venereologica.

[23]  Anthony J. Durkin,et al.  Chromophore concentrations, absorption and scattering properties of human skin in-vivo. , 2009, Optics express.

[24]  T. Gambichler,et al.  In vivo data of epidermal thickness evaluated by optical coherence tomography: effects of age, gender, skin type, and anatomic site. , 2006, Journal of dermatological science.

[25]  Sean McLoone,et al.  Aminolaevulinic acid diffusion characteristics in ‘in vitro’ normal human skin and actinic keratosis: implications for topical photodynamic therapy , 2008, Photodermatology, photoimmunology & photomedicine.

[26]  T. King,et al.  Effect of target biological tissue and choice of light source on penetration depth and resolution in optical coherence tomography. , 2004, Journal of biomedical optics.

[27]  O Jolivet,et al.  Characterization of the skin in vivo by high resolution magnetic resonance imaging: water behavior and age-related effects. , 1993, The Journal of investigative dermatology.

[28]  R. Webb,et al.  In vivo confocal scanning laser microscopy of human skin: melanin provides strong contrast. , 1995, The Journal of investigative dermatology.

[29]  R. Webb,et al.  In vivo confocal scanning laser microscopy of human skin II: advances in instrumentation and comparison with histology. , 1999, The Journal of investigative dermatology.

[30]  J. Fujimoto,et al.  Ultrahigh-resolution optical coherence tomography using continuum generation in an air-silica microstructure optical fiber. , 2001, Optics letters.

[31]  T. Gambichler,et al.  Correlation between clinical scoring of allergic patch test reactions and optical coherence tomography. , 2005, Journal of biomedical optics.

[32]  D. Komitowski Epidermal-dermal junction during experimental skin carcinogenesis and cocarcinogenesis as revealed by scanning electron microscopy. , 1982, The Journal of investigative dermatology.

[33]  A. Fercher,et al.  Performance of fourier domain vs. time domain optical coherence tomography. , 2003, Optics express.

[34]  W Drexler,et al.  Compact, low-cost Ti:Al2O3 laser for in vivo ultrahigh-resolution optical coherence tomography. , 2003, Optics letters.

[35]  A. N. Bashkatov,et al.  Optical properties of human skin, subcutaneous and mucous tissues in the wavelength range from 400 to 2000 nm , 2005 .

[36]  J K Barton,et al.  Investigating Sun-damaged Skin and Actinic Keratosis with Optical Coherence Tomography: a Pilot Study , 2022 .

[37]  W. Sterry,et al.  A randomised study of topical 5% imiquimod vs. topical 5‐fluorouracil vs. cryosurgery in immunocompetent patients with actinic keratoses: a comparison of clinical and histological outcomes including 1‐year follow‐up , 2007, The British journal of dermatology.

[38]  M. V. van Gemert,et al.  Noninvasive imaging of in vivo blood flow velocity using optical Doppler tomography. , 1997, Optics letters.

[39]  J. Fujimoto,et al.  Ultrahigh speed spectral / Fourier domain OCT ophthalmic imaging at 70,000 to 312,500 axial scans per second. , 2008, Optics express.

[40]  B. Young,et al.  Wheater's Functional Histology: A Text and Colour Atlas , 1993 .

[41]  A. Fercher,et al.  Eye-length measurement by interferometry with partially coherent light. , 1988, Optics letters.

[42]  Thilo Gambichler,et al.  In vivo optical coherence tomography of basal cell carcinoma. , 2007, Journal of dermatological science.

[43]  J. Ruíz-Cabello,et al.  Magnetic resonance methods and applications in pharmaceutical research. , 2008, Journal of pharmaceutical sciences.

[44]  W. Drexler,et al.  Three-dimensional optical coherence tomography at 1050 nm versus 800 nm in retinal pathologies: enhanced performance and choroidal penetration in cataract patients. , 2007, Journal of biomedical optics.

[45]  J. R. Taylor,et al.  Temporal and noise characteristics of continuous-wave-pumped continuum generation in holey fibers around 1300nm , 2004 .

[46]  H H Wolff,et al.  Changes in function and morphology of normal human skin: evaluation using optical coherence tomography , 2004, The British journal of dermatology.

[47]  H Ermert,et al.  Sonography of the skin at 100 MHz enables in vivo visualization of stratum corneum and viable epidermis in palmar skin and psoriatic plaques. , 1999, The Journal of investigative dermatology.

[48]  G. Gelikonov,et al.  In vivo optical coherence tomography imaging of human skin: norm and pathology , 2000, Skin research and technology : official journal of International Society for Bioengineering and the Skin (ISBS) [and] International Society for Digital Imaging of Skin (ISDIS) [and] International Society for Skin Imaging.

[49]  Karsten König,et al.  Clinical multiphoton tomography , 2008, Journal of biophotonics.

[50]  G. Jemec,et al.  In vivo thickness measurement of basal cell carcinoma and actinic keratosis with optical coherence tomography and 20‐MHz ultrasound , 2009, The British journal of dermatology.

[51]  Jun Zhang,et al.  Determination of burn depth by polarization-sensitive optical coherence tomography , 1999, Photonics West - Biomedical Optics.

[52]  Adam Boretsky,et al.  Dermal scatter reduction in human skin: A method using controlled application of glycerol , 2009, Lasers in surgery and medicine.

[53]  Wolfgang Drexler,et al.  State-of-the-art retinal optical coherence tomography , 2008, Progress in Retinal and Eye Research.

[54]  Barry Cense,et al.  Birefringence measurements in human skin using polarization-sensitive optical coherence tomography. , 2004, Journal of biomedical optics.

[55]  Changhuei Yang,et al.  Sensitivity advantage of swept source and Fourier domain optical coherence tomography. , 2003, Optics express.

[56]  J. Fujimoto,et al.  Introduction to Optical Coherence Tomography , 2008 .

[57]  P Altmeyer,et al.  Malignant melanoma in 20-MHz B scan sonography. , 1992, Dermatology.

[58]  A. Fercher,et al.  Measurement of intraocular distances by backscattering spectral interferometry , 1995 .

[59]  Marcia Ramos-e-Silva,et al.  Dermoscopy: basic concepts , 2008, International journal of dermatology.

[60]  Iris Riemann,et al.  High-resolution multiphoton tomography of human skin with subcellular spatial resolution and picosecond time resolution. , 2003, Journal of biomedical optics.

[61]  D L Farkas,et al.  Noninvasive imaging of living human skin with dual-wavelength optical coherence tomography in two and three dimensions. , 1998, Journal of biomedical optics.

[62]  J. Fujimoto,et al.  Fourier Domain Mode Locking (FDML): A new laser operating regime and applications for optical coherence tomography. , 2006, Optics express.

[63]  I. Zalaudek,et al.  Dermoscopy--the ultimate tool for melanoma diagnosis. , 2009, Seminars in cutaneous medicine and surgery.

[64]  R. Steiner,et al.  Optical Coherence Tomography: Clinical Applications in Dermatology , 2003 .

[65]  J. Schmitt,et al.  Optical-coherence tomography of a dense tissue: statistics of attenuation and backscattering. , 1994, Physics in medicine and biology.

[66]  C. Longo,et al.  Microscopic in vivo description of cellular architecture of dermoscopic pigment network in nevi and melanomas. , 2005, Archives of dermatology.

[67]  S. Boyce,et al.  Improvement of Epidermal Barrier Properties in Cultured Skin Substitutes after Grafting onto Athymic Mice , 2006, Skin Pharmacology and Physiology.

[68]  B E Bouma,et al.  Optical Coherence Tomographic Imaging of Human Tissue at 1.55 μm and 1.81 μm Using Er- and Tm-Doped Fiber Sources. , 1998, Journal of biomedical optics.

[69]  R Birngruber,et al.  Optical coherence tomography of the human skin. , 1997, Journal of the American Academy of Dermatology.

[70]  G. Ripandelli,et al.  Optical coherence tomography. , 1998, Seminars in ophthalmology.

[71]  Tracy Stoudemayer,et al.  Optical coherence tomography in dermatology , 1999 .

[72]  Karsten König,et al.  Sensitivity and specificity of multiphoton laser tomography for in vivo and ex vivo diagnosis of malignant melanoma. , 2009, The Journal of investigative dermatology.

[73]  J. Welzel Optical coherence tomography in dermatology: a review , 2001, Skin research and technology : official journal of International Society for Bioengineering and the Skin (ISBS) [and] International Society for Digital Imaging of Skin (ISDIS) [and] International Society for Skin Imaging.

[74]  Cesare Massone,et al.  Diagnostic applicability of in vivo confocal laser scanning microscopy in melanocytic skin tumors. , 2005, The Journal of investigative dermatology.

[75]  Stefan Kray,et al.  High-resolution simultaneous dual-band spectral domain optical coherence tomography. , 2009 .

[76]  M. Schmid-Wendtner,et al.  Ultrasound technology in dermatology. , 2008, Seminars in cutaneous medicine and surgery.