An Improved Feedforward Control Method Considering PLL Dynamics to Improve Weak Grid Stability of Grid-Connected Inverters

Phase-locked loop (PLL) is commonly used for three-phase grid-connected inverters to obtain the information of grid synchronization, and PLL dynamics are the key factors for stable operation of the inverters. Under weak grid conditions, the coupling between PLL and grid impedance can result in harmonic resonance, or even instability in the system. In this paper, the effect of PLL dynamics and grid impedance on the stability of three-phase grid-connected inverters is studied with the d–q impedance model. Besides, the variable transfer relationship is used to analyze the influence of PLL perturbations on output current under weak grid conditions. To suppress low-order harmonics of the network current caused by PLL perturbations under weak grid conditions, a novel feedforward control method is proposed to compensate PLL perturbations and revise the output impedance, where the operation of the inverter and PLL dynamics have been taken into account in the design process. By analyzing the impedance characteristic of the system, it can be demonstrated that the proposed method can enhance the stability of grid-connected inverters under weak grid conditions and reduce the impact of PLL perturbations on grid-connecting current. The experimental results indicate that the low-order harmonics of the network current can be suppressed effectively, which verifies the analysis.

[1]  Yasser Abdel-Rady I. Mohamed,et al.  Robust Vector Control of a Very Weak-Grid-Connected Voltage-Source Converter Considering the Phase-Locked Loop Dynamics , 2017, IEEE Transactions on Power Electronics.

[2]  Frede Blaabjerg,et al.  An Active Damper for Stabilizing Power-Electronics-Based AC Systems , 2014 .

[3]  Bo Wen,et al.  Analysis of Phase-Locked Loop Low-Frequency Stability in Three-Phase Grid-Connected Power Converters Considering Impedance Interactions , 2015, IEEE Transactions on Industrial Electronics.

[4]  Bo Wen,et al.  Impedance-Based Analysis of Grid-Synchronization Stability for Three-Phase Paralleled Converters , 2014, IEEE Transactions on Power Electronics.

[5]  Jian Sun,et al.  Small-Signal Methods for AC Distributed Power Systems–A Review , 2009, IEEE Transactions on Power Electronics.

[6]  Frede Blaabjerg,et al.  Unified Impedance Model of Grid-Connected Voltage-Source Converters , 2018, IEEE Transactions on Power Electronics.

[7]  Jian Sun,et al.  Adaptive Control of Grid-Connected Inverters Based on Online Grid Impedance Measurements , 2014, IEEE Transactions on Sustainable Energy.

[8]  Xu Cai,et al.  A Modified Sequence-Domain Impedance Definition and Its Equivalence to the dq-Domain Impedance Definition for the Stability Analysis of AC Power Electronic Systems , 2016, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[9]  Heng Nian,et al.  Direct power control of voltage source inverter in a virtual synchronous reference frame during frequency variation and network unbalance , 2016 .

[10]  Frede Blaabjerg,et al.  Overview of Control and Grid Synchronization for Distributed Power Generation Systems , 2006, IEEE Transactions on Industrial Electronics.

[11]  Frede Blaabjerg,et al.  Modeling and Analysis of Harmonic Stability in an AC Power-Electronics-Based Power System , 2014, IEEE Transactions on Power Electronics.

[12]  Massimo Bongiorno,et al.  Input-Admittance Calculation and Shaping for Controlled Voltage-Source Converters , 2007, IEEE Transactions on Industrial Electronics.

[13]  Bo Wen,et al.  Analysis of D-Q Small-Signal Impedance of Grid-Tied Inverters , 2016, IEEE Transactions on Power Electronics.

[14]  Dongsheng Yang,et al.  Impedance Shaping of the Grid-Connected Inverter with LCL Filter to Improve Its Adaptability to the Weak Grid Condition , 2014, IEEE Transactions on Power Electronics.

[15]  Frede Blaabjerg,et al.  Couplings in Phase Domain Impedance Modeling of Grid-Connected Converters , 2016, IEEE Transactions on Power Electronics.

[16]  Jie Chen,et al.  Impedance-Phased Dynamic Control Method for Grid-Connected Inverters in a Weak Grid , 2017, IEEE Transactions on Power Electronics.

[17]  A. Gole,et al.  Impact of Short-Circuit Ratio and Phase-Locked-Loop Parameters on the Small-Signal Behavior of a VSC-HVDC Converter , 2014, IEEE Transactions on Power Delivery.

[18]  Xiong Du,et al.  Using asymmetric current controller to improve the stability of grid-inverter system due to PLL effect , 2017, 2017 IEEE 18th Workshop on Control and Modeling for Power Electronics (COMPEL).

[19]  Jian Sun,et al.  Frequency-domain coupling in two-level VSC small-signal dynamics , 2017, 2017 IEEE 18th Workshop on Control and Modeling for Power Electronics (COMPEL).

[20]  Frede Blaabjerg,et al.  Virtual-Impedance-Based Control for Voltage-Source and Current-Source Converters , 2015, IEEE Transactions on Power Electronics.

[21]  Jian Sun,et al.  Impedance Modeling and Analysis of Grid-Connected Voltage-Source Converters , 2014, IEEE Transactions on Power Electronics.

[22]  Frede Blaabjerg,et al.  Analysis of Middle Frequency Resonance in DFIG System Considering Phase-Locked Loop , 2018, IEEE Transactions on Power Electronics.

[23]  Xibo Yuan,et al.  Grid Harmonics Suppression Scheme for LCL-Type Grid-Connected Inverters Based on Output Admittance Revision , 2015, IEEE Transactions on Sustainable Energy.

[24]  Lennart Harnefors,et al.  Modeling of Three-Phase Dynamic Systems Using Complex Transfer Functions and Transfer Matrices , 2007, IEEE Transactions on Industrial Electronics.

[25]  Dong Wang,et al.  Modeling of Grid-Connected DFIG-Based Wind Turbines for DC-Link Voltage Stability Analysis , 2015, IEEE Transactions on Sustainable Energy.