Characteristics of 3D Micro-Structured Semiconductor High Efficiency Neutron Detectors

Silicon diodes with large aspect ratio perforated micro-structures backfilled with 6LiF show a dramatic increase in neutron detection efficiency beyond that of conventional thin-film coated planar devices. Described in the following are advancements in the technology with increased perforation depths. Perforated silicon diodes with three different etched micro-structure patterns were tested for neutron counting efficiency. The etched micro-structure patterns consisted of circular holes, straight trenches, and continuous sinusoidal waves, with each pattern etched 200 mum deep. Normal incident neutron counting efficiencies were determined to be 9.7%, 12.6%, and 16.2% for circular hole, straight trench, and sinusoidal devices, respectively, at a reverse bias of 3 volts. The perforated neutron detectors demonstrate limited sensitivity to high-energy photon irradiation with a 60Co gamma-ray source. This work is part of on-going research to develop solid-state semiconductor neutron detectors with high detection efficiencies and uniform angular responses.

[1]  R. Klann,et al.  New surface morphology for low stress thin-film-coated thermal neutron detectors , 2001, 2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310).

[2]  C. L. Cheung,et al.  Fabrication of Pillar-structured thermal neutron detectors , 2007, 2007 IEEE Nuclear Science Symposium Conference Record.

[3]  Douglas S. McGregor,et al.  Spectral identification of thin-film-coated and solid-form semiconductor neutron detectors , 2004 .

[4]  W. L. Dunn,et al.  Perforated diode neutron detector modules fabricated from high-purity silicon , 2009 .

[5]  J. Shultis,et al.  Perforated Diode Fabrication for Neutron Detection , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[6]  Victor Perez-Mendez,et al.  High efficiency neutron sensitive amorphous silicon pixel detectors , 1994 .

[7]  D. Mcgregor,et al.  Angular response of perforated silicon diode high efficiency neutron detectors , 2007, 2007 IEEE Nuclear Science Symposium Conference Record.

[8]  S. Pospíšil,et al.  Si Diode as a Small Detector of Slow Neutrons , 1993 .

[9]  R. Klann,et al.  Design considerations for thin film coated semiconductor thermal neutron detectors—I: basics regarding alpha particle emitting neutron reactive films , 2003 .

[10]  Josef Uher,et al.  Characterization of 3D thermal neutron semiconductor detectors , 2007 .

[11]  Neutron dosimeters employing high-efficiency perforated semiconductor detectors , 2007 .

[12]  J. Shultis,et al.  Efficiencies of coated and perforated semiconductor neutron detectors , 2004, IEEE Transactions on Nuclear Science.