Effect of anastomosis angle on the localization of disturbed flow in 'side-to-end' fistulae for haemodialysis access.

BACKGROUND Early failure of the vascular access for haemodialysis (HD) after the surgical creation of a radial-cephalic arteriovenous fistula (AVF) occurs mainly due to a juxta-anastomotic stenosis. Even if elevated blood flow induces high wall shear stress, we have recently shown that disturbed flow, characterized by low and reciprocating flow, may develop in zones of the AVF where it can provide a good indication of the sites of future stenoses. The present study was aimed at investigating whether the anastomosis angle influences disturbed flow in radial-cephalic 'side-to-end' AVF. METHODS By means of a parametric AVF model we created four equivalent meshes with anastomosis angles of 30°, 45°, 60° and 90°, respectively. We then performed transient, non-Newtonian computational fluid dynamics simulations using, as boundary conditions, previously measured blood volume flow and division ratio in subjects requiring primary access. The relative residence time (RRT), a robust indicator of disturbed flow, was calculated for the overall wall surface and disturbed flow was localized as areas having RRT > 1. Quantitative characterization and statistical tests were employed to assess the difference in RRT medians between the four anastomosis angle cases. RESULTS Disturbed flow was located in all AVF models in the same areas where flow recirculation and stagnation occurred, on the inner wall of the swing segment (SS) and on the arterial wall at the anastomosis floor (AF). A smaller angle AVF had smaller disturbed flow areas with lower RRT peak values, either on the venous or the arterial limb. There were significant differences in the RRT medians on the SS and on the AF between sharper (30° and 45°) and wider (60° or 90°) angles. CONCLUSIONS We have found that in 'side-to-end' radial-cephalic AVFs for HD, the anastomosis angle does impact on the local disturbed flow patterns. Among the four geometries we considered in this study, the smaller angle (30°) would be the preferred choice that minimizes the development of neointima. Clinicians should consider this at the time of AVF creation because the anastomosis angle is in part amenable to surgical manipulation.

[1]  William Yang,et al.  Numerical simulation of the haemodynamics in end‐to‐side anastomoses , 2011 .

[2]  A. Go,et al.  Transplant nephrectomy improves survival following a failed renal allograft. , 2010, Journal of the American Society of Nephrology.

[3]  S. Heffelfinger,et al.  Cellular phenotypes in human stenotic lesions from haemodialysis vascular access. , 2009, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[4]  H. Wasse Catheter‐Related Mortality among ESRD Patients , 2008, Seminars in dialysis.

[5]  C. Wanner,et al.  EBPG on Vascular Access. , 2007, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[6]  P. Ravani,et al.  Biology of arteriovenous fistula failure. , 2007, Journal of nephrology.

[7]  Y S Morsi,et al.  The effect of angle on wall shear stresses in a LIMA to LAD anastomosis: Numerical modelling of pulsatile flow , 2006, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[8]  Prabir Roy-Chaudhury,et al.  Early arteriovenous fistula failure: a logical proposal for when and how to intervene. , 2006, Clinical journal of the American Society of Nephrology : CJASN.

[9]  J. Ayus,et al.  Editorial Focus: Transplant Nephrectomy: At the Peril of Dialysis Patients: Ignoring the Failed Transplant , 2005, Seminars in dialysis.

[10]  M. Walsh,et al.  On Reducing Abnormal Hemodynamics in the Femoral End-to-Side Anastomosis: The Influence of Mechanical Factors , 2005, Annals of Biomedical Engineering.

[11]  A. Hazel,et al.  Spatial comparison between wall shear stress measures and porcine arterial endothelial permeability. , 2004, American journal of physiology. Heart and circulatory physiology.

[12]  G. Beathard,et al.  Aggressive treatment of early fistula failure. , 2003, Kidney international.

[13]  W. Oldenburg,et al.  Improved patency of prosthetic arteriovenous grafts with an acute anastomotic angle and flow diffuser. , 2003, Journal of vascular surgery.

[14]  Daniel Hayoz,et al.  Low-pressure environment and remodelling of the forearm vein in Brescia-Cimino haemodialysis access. , 2002, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[15]  K. Konner The anastomosis of the arteriovenous fistula--common errors and their avoidance. , 2002, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[16]  Anna Hart,et al.  Mann-Whitney test is not just a test of medians: differences in spread can be important , 2001, BMJ : British Medical Journal.

[17]  B L Langille,et al.  Effects of anastomotic angle on vascular tissue responses at end-to-side arterial grafts. , 2001, Journal of vascular surgery.

[18]  T V How,et al.  Flow patterns in the radiocephalic arteriovenous fistula: an in vitro study. , 1999, Journal of biomechanics.

[19]  T. How,et al.  Characterizing flow distributions in AV fistulae for haemodialysis access. , 1998, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[20]  D. Ku,et al.  Pulsatile flow in the human left coronary artery bifurcation: average conditions. , 1996, Journal of biomechanical engineering.

[21]  H Nygaard,et al.  The anastomosis angle does change the flow fields at vascular end-to-side anastomoses in vivo. , 1995, Journal of vascular surgery.

[22]  J D Thomas,et al.  The effect of angle and flow rate upon hemodynamics in distal vascular graft anastomoses: a numerical model study. , 1991, Journal of biomechanical engineering.

[23]  R Core Team,et al.  R: A language and environment for statistical computing. , 2014 .

[24]  Andrea Remuzzi,et al.  Disturbed flow in radial-cephalic arteriovenous fistulae for haemodialysis: low and oscillating shear stress locates the sites of stenosis. , 2012, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[25]  M. Salifu,et al.  Frequency of swing-segment stenosis in referred dialysis patients with angiographically documented lesions. , 2008, American journal of kidney diseases : the official journal of the National Kidney Foundation.

[26]  J. Éthier,et al.  Clinical practice guidelines for vascular access. , 2006, American journal of kidney diseases : the official journal of the National Kidney Foundation.

[27]  L. Antiga,et al.  Radial artery remodeling in response to shear stress increase within arteriovenous fistula for hemodialysis access. , 2003, Endothelium : journal of endothelial cell research.

[28]  T V How,et al.  Sites of stenosis in AV fistulae for haemodialysis access. , 1999, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.