Heterodyne interferometric surface plasmon resonance biosensor

A high-sensitivity surface plasmon resonance (SPR) biosensor is constructed by using a common-path heterodyne interferometric system. The beam combiner is employed to combine the modulated He-Ne TE-wave and TM-wave into a heterodyne light source with a frequency difference of 60 kHz. Using the common-path heterodyne interferometric system to obtain the phase shift between the two waves has the advantage of high-sensitivity real-time phase detection for monitoring molecular interactions. By detecting the phase shift, the proposed SPR biosensor is employed to monitor the interactions between the sheep IgG covalently immobilized on the sensor chip surface and the anti-sheep IgG contained in the running buffer.

[1]  Dwight U. Bartholomew,et al.  Integrated analytical sensors: the use of the TISPR-1 as a biosensor , 1999 .

[2]  B. Liedberg,et al.  Surface plasmon resonance for gas detection and biosensing , 1983 .

[3]  Jiang Hong,et al.  Immunosensor based on optical heterodyne phase detection , 2001 .

[4]  D. Malacara Optical Shop Testing , 1978 .

[5]  R. Rich,et al.  Survey of the 1999 surface plasmon resonance biosensor literature , 2000, Journal of molecular recognition : JMR.

[6]  Liann-Be Chang,et al.  High-sensitivity sensor based on surface plasmon resonance and heterodyne interferometry , 2003 .

[7]  A. Otto Excitation of nonradiative surface plasma waves in silver by the method of frustrated total reflection , 1968 .

[8]  S. G. Nelson,et al.  High sensitivity surface plasmon resonace sensor based on phase detection , 1996 .

[9]  Andreas Brecht,et al.  Compact surface plasmon resonance-transducers with spectral readout for biosensing applications , 1999 .

[10]  J. R. Sambles,et al.  Differential ellipsometric surface plasmon resonance sensors with liquid crystal polarization modulators , 2004 .

[11]  Peter Westphal,et al.  Biomolecular detection by surface plasmon enhanced ellipsometry , 2002 .

[12]  Sen-Fang Sui,et al.  Characterization of surface plasmon resonance biosensor , 2000 .

[13]  Petr I. Nikitin,et al.  Interferometer based on a surface-plasmon resonance for sensor applications , 1997 .

[14]  Günter Gauglitz,et al.  Surface plasmon resonance sensors: review , 1999 .

[15]  B. Liedberg,et al.  Biosensing with surface plasmon resonance--how it all started. , 1995, Biosensors & bioelectronics.

[16]  K. Kajikawa,et al.  Phase detection of surface plasmon resonance using rotating analyzer method , 2005 .

[17]  Bo Johnsson,et al.  A novel hydrogel matrix on gold surfaces in surface plasmon resonance sensors for fast and efficient covalent immobilization of ligands , 1990 .