Bit error rate measurement system for RF integrated circuits

This paper proposes a bit error rate (BER) measurement system utilizing vector signal analyzer (VSA) instrument built-in analog digital converter (ADC) and ideal digital baseband receiver of VSA software for RF integrated circuits (RFICs) such as RF amplifier, RF mixer and RF receiver. Usually, BER performance is estimated in transceiver with built-in digital baseband circuits. In the past, RF designers could not estimate RFICs effect to BER test without digital baseband circuits and vice versa for digital baseband designers. It is helpful to understand RFICs without digital baseband circuits to BER test can reduce certain risk before integrating RFICs with digital baseband circuits. Therefore, an implementation of output signal to noise ratio (SNR) calibration in a specified bandwidth and measurement method combined VSA instrument, VSA software and Advanced Design System (ADS) is used for BER measurement.

[1]  I Eizmendi,et al.  Improving measurement techniques for testing digital broadcasting systems , 2010, 2010 IEEE Instrumentation & Measurement Technology Conference Proceedings.

[2]  Earl McCune,et al.  Practical Digital Wireless Signals , 2010 .

[3]  M.B. Steer,et al.  Accurate estimation of digital communication system metrics - SNR, EVM and /spl rho/ in a nonlinear amplifier environment , 2004, 64th ARFTG Microwave Measurements Conference, Fall 2004..