Additional electrodes on the Quartet™ LV lead provide more programmable pacing options than bipolar and tripolar equivalents
暂无分享,去创建一个
C. Leclercq | C. Rinaldi | C. Pappone | K. Ryu | A. Fischer | J. Sperzel | G. Tomassoni | B. Thibault | K. Gutleben | L. McSpadden | D. O'Donnell | H. Razavi
[1] M. Biffi,et al. Performance of a novel left ventricular lead with short bipolar spacing for cardiac resynchronization therapy: primary results of the Attain Performa quadripolar left ventricular lead study. , 2015, Heart rhythm.
[2] C. Rinaldi,et al. Cardiac Resynchronization Therapy Delivered Via a Multipolar Left Ventricular Lead is Associated with Reduced Mortality and Elimination of Phrenic Nerve Stimulation: Long‐Term Follow‐Up from a Multicenter Registry , 2015, Journal of cardiovascular electrophysiology.
[3] A. Natale,et al. Hospitalization rates and associated cost analysis of cardiac resynchronization therapy with an implantable defibrillator and quadripolar vs. bipolar left ventricular leads: a comparative effectiveness study , 2014, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.
[4] L. Calò,et al. Acute echocardiographic optimization of multiple stimulation configurations of cardiac resynchronization therapy through quadripolar left ventricular pacing: a tailored approach. , 2014, American heart journal.
[5] L. Tavazzi,et al. Multipoint left ventricular pacing improves acute hemodynamic response assessed with pressure-volume loops in cardiac resynchronization therapy patients. , 2014, Heart rhythm.
[6] A. Vado,et al. Single-center experience of a quadripolar pacing lead for cardiac resynchronization therapy , 2014, Journal of Interventional Cardiac Electrophysiology.
[7] Christophe Leclercq,et al. Acute effects of multisite left ventricular pacing on mechanical dyssynchrony in patients receiving cardiac resynchronization therapy. , 2013, Journal of cardiac failure.
[8] I. Fernández‐Lozano,et al. Improvement in Hemodynamic Response Using a Quadripolar LV Lead , 2013, Pacing and clinical electrophysiology : PACE.
[9] P. Khairy,et al. Acute haemodynamic comparison of multisite and biventricular pacing with a quadripolar left ventricular lead. , 2013, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.
[10] J. Baker,et al. Postoperative Performance of the Quartet® Left Ventricular Heart Lead , 2013, Journal of cardiovascular electrophysiology.
[11] A. Natale,et al. Clinical and procedural outcome of patients implanted with a quadripolar left ventricular lead: early results of a prospective multicenter study. , 2012, Heart rhythm.
[12] M. Biffi,et al. Effect of Bipolar Electrode Spacing on Phrenic Nerve Stimulation and Left Ventricular Pacing Thresholds: An Acute Canine Study , 2012, Circulation. Arrhythmia and electrophysiology.
[13] G. Boriani,et al. First prospective, multi-centre clinical experience with a novel left ventricular quadripolar lead. , 2012, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.
[14] K. Rhode,et al. The Acute Hemodynamic Response to LV Pacing within Individual Branches of the Coronary Sinus using a Quadripolar Lead , 2012, Pacing and clinical electrophysiology : PACE.
[15] L. Goldman,et al. Statin use and postoperative atrial fibrillation after major noncardiac surgery. , 2012, Heart rhythm.
[16] M. Ginks,et al. Initial Single‐Center Experience of a Quadripolar Pacing Lead for Cardiac Resynchronization Therapy , 2011, Pacing and clinical electrophysiology : PACE.
[17] Wojciech Zareba,et al. Left Ventricular Lead Position and Clinical Outcome in the Multicenter Automatic Defibrillator Implantation Trial–Cardiac Resynchronization Therapy (MADIT-CRT) Trial , 2011, Circulation.
[18] C. Rinaldi,et al. Use of a quadripolar left ventricular lead to achieve successful implantation in patients with previous failed attempts at cardiac resynchronization therapy , 2011, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.
[19] K. Ryu,et al. Pacing electrode selection in a quadripolar left heart lead determines presence or absence of phrenic nerve stimulation. , 2010, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.
[20] Wojciech Zareba,et al. Cardiac-resynchronization therapy for the prevention of heart-failure events. , 2009, The New England journal of medicine.
[21] J. Daubert,et al. The effect of cardiac resynchronization on morbidity and mortality in heart failure. , 2005, The New England journal of medicine.
[22] Christophe Leclercq,et al. A review of multisite pacing to achieve cardiac resynchronization therapy. , 2015, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.
[23] C. Rinaldi,et al. Elimination of phrenic nerve stimulation occurring during CRT , 2011, Journal of Interventional Cardiac Electrophysiology.