aSi EPIDs for the in-vivo dosimetry of static and dynamic beams

Abstract Portal imaging by amorphous silicon (aSi) photodiode is currently the most applied technology for in-vivo dosimetry (IVD) of static and dynamic radiotherapy beams. The strategy, adopted in this work to perform the IVD procedure by aSi EPID, is based on: in patient reconstruction of the isocenter dose and day to day comparison between 2D-portal images to verify the reproducibility of treatment delivery. About 20.000 tests have been carried out in this last 3 years in 8 radiotherapy centers using the SOFTDISO program. The IVD results show that: (i) the procedure can be implemented for linacs of different manufacturer, (ii) the IVD analysis can be obtained on a computer screen, in quasi real time (about 2 min after the treatment delivery) and (iii) once the causes of the discrepancies were eliminated, all the global IVD tests for single patient were within the acceptance criteria defined by: ±5% for the isocenter dose, and P γ ≥90% of the checked points for the 2D portal image γ-analysis. This work is the result of a project supported by the Istituto Nazionale di Fisica Nucleare (INFN) and Universita Cattolica del S.Cuore (UCSC).

[1]  Savino Cilla,et al.  A National project for in vivo dosimetry procedures in radiotherapy: First results , 2012 .

[2]  Xiao-wu Deng,et al.  Gantry angle-dependent correction of dose detection error due to panel position displacement in IMRT dose verification using EPIDs. , 2014, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[3]  J J Sonke,et al.  Dose-response and ghosting effects of an amorphous silicon electronic portal imaging device. , 2003, Medical physics.

[4]  L. Azario,et al.  An in-vivo dosimetry procedure for Elekta step and shoot IMRT. , 2014, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[5]  P. Lambin,et al.  A literature review of electronic portal imaging for radiotherapy dosimetry. , 2008, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[6]  Ben Mijnheer,et al.  State of the art of in vivo dosimetry. , 2008, Radiation protection dosimetry.

[7]  Savino Cilla,et al.  Integration between in vivo dosimetry and image guided radiotherapy for lung tumors. , 2009, Medical physics.

[8]  Savino Cilla,et al.  aSi-EPID transit signal calibration for dynamic beams: a needful step for the IMRT in vivo dosimetry , 2013, Medical & Biological Engineering & Computing.

[9]  M van Herk,et al.  Catching errors with in vivo EPID dosimetry. , 2010, Medical physics.

[10]  B. Poppe,et al.  Clinical performance of a transmission detector array for the permanent supervision of IMRT deliveries. , 2010, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[11]  F Ballester,et al.  QA of dynamic MLC based on EPID portal dosimetry. , 2012, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[12]  Ben Mijnheer,et al.  In vivo dosimetry in external beam radiotherapy. , 2013, Medical physics.

[13]  D. Low,et al.  A technique for the quantitative evaluation of dose distributions. , 1998, Medical physics.

[14]  D. Huyskens,et al.  A quantitative evaluation of IMRT dose distributions: refinement and clinical assessment of the gamma evaluation. , 2002, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.