Which mesh for hernia repair?

INTRODUCTION The concept of using a mesh to repair hernias was introduced over 50 years ago. Mesh repair is now standard in most countries and widely accepted as superior to primary suture repair. As a result, there has been a rapid growth in the variety of meshes available and choosing the appropriate one can be difficult. This article outlines the general properties of meshes and factors to be considered when selecting one. MATERIALS AND METHODS We performed a search of the medical literature from 1950 to 1 May 2009, as indexed by Medline, using the PubMed search engine (www.pubmed.gov). To capture all potentially relevant articles with the highest degree of sensitivity, the search terms were intentionally broad. We used the following terms: 'mesh, pore size, strength, recurrence, complications, lightweight, properties'. We also hand-searched the bibliographies of relevant articles and product literature to identify additional pertinent reports. RESULTS AND CONCLUSIONS The most important properties of meshes were found to be the type of filament, tensile strength and porosity. These determine the weight of the mesh and its biocompatibility. The tensile strength required is much less than originally presumed and light-weight meshes are thought to be superior due to their increased flexibility and reduction in discomfort. Large pores are also associated with a reduced risk of infection and shrinkage. For meshes placed in the peritoneal cavity, consideration should also be given to the risk of adhesion formation. A variety of composite meshes have been promoted to address this, but none appears superior to the others. Finally, biomaterials such as acellular dermis have a place for use in infected fields but have yet to prove their worth in routine hernia repair.

[1]  I. Lichtenstein,et al.  Biomaterials for "tension-free" hernioplasties and principles of their applications. , 1995, Minerva chirurgica.

[2]  L. Avtan,et al.  Mesh infections after laparoscopic inguinal hernia repair. , 1997, Surgical laparoscopy & endoscopy.

[3]  Chronic groin sepsis following tension-free inguinal hernioplasty. , 1999 .

[4]  Volker Schumpelick,et al.  Polymers in hernia repair–common polyester vs. polypropylene surgical meshes , 2000 .

[5]  R. Rege,et al.  Factors Affecting Recurrence following Incisional Herniorrhaphy , 2000, World Journal of Surgery.

[6]  P. O’Dwyer,et al.  Outcome of patients with severe chronic pain following repair of groin hernia , 2002, The British journal of surgery.

[7]  B. Klosterhalfen,et al.  Do multifilament alloplastic meshes increase the infection rate? Analysis of the polymeric surface, the bacteria adherence, and the in vivo consequences in a rat model. , 2002, Journal of biomedical materials research.

[8]  U Klinge,et al.  Impact of polymer pore size on the interface scar formation in a rat model. , 2002, The Journal of surgical research.

[9]  G. Maddern,et al.  A peeling mesh , 2002, Hernia.

[10]  U. Klinge,et al.  Prosthetic implants for hernia repair , 2003, The British journal of surgery.

[11]  J. Bruce,et al.  A Review of Chronic Pain After Inguinal Herniorrhaphy , 2003, The Clinical journal of pain.

[12]  Volker Schumpelick,et al.  Meshes: Benefits and Risks , 2004, Springer Berlin Heidelberg.

[13]  Introduction of polyethylene terephthalate mesh (KoSa hochfest) for abdominal hernia repair: an animal experimental study. , 2004, Bio-medical materials and engineering.

[14]  B. Klosterhalfen,et al.  Decreased collagen type I/III ratio in patients with recurring hernia after implantation of alloplastic prostheses , 2004, Langenbeck's Archives of Surgery.

[15]  H. Lippert,et al.  Influence of Titanium Coating on the Biocompatibility of a Heavyweight Polypropylene Mesh , 2004, European Surgical Research.

[16]  E. Verdaasdonk,et al.  Long-term Follow-up of a Randomized Controlled Trial of Suture Versus Mesh Repair of Incisional Hernia , 2004, Annals of surgery.

[17]  B. Matthews,et al.  The susceptibility of prosthetic biomaterials to infection , 2005, Surgical Endoscopy And Other Interventional Techniques.

[18]  S. Bringman,et al.  One year results of a randomised controlled multi-centre study comparing Prolene and Vypro II-mesh in Lichtenstein hernioplasty , 2005, Hernia.

[19]  Uwe Klinge,et al.  The lightweight and large porous mesh concept for hernia repair , 2005, Expert review of medical devices.

[20]  S. Sauerland,et al.  Primary incisional hernia repair with or without polypropylene mesh: a report on 384 patients with 5-year follow-up , 2005, Langenbeck's Archives of Surgery.

[21]  D. Palmes,et al.  Impact of Polypropylene Amount on Functional Outcome and Quality of Life after Inguinal Hernia Repair by the TAPP Procedure Using Pure, Mixed, and Titanium-coated Meshes , 2006, World Journal of Surgery.

[22]  B. Matthews,et al.  Normal intraabdominal pressure in healthy adults. , 2005, The Journal of surgical research.

[23]  P. O’Dwyer,et al.  Randomized clinical trial assessing impact of a lightweight or heavyweight mesh on chronic pain after inguinal hernia repair , 2005, The British journal of surgery.

[24]  A. Çakmak,et al.  Incisional hernia treatment with polypropylene graft: results of 10 years , 2006, Hernia.

[25]  B. Klosterhalfen,et al.  Biological response to mesh , 2003, European Surgery.

[26]  B. Agarwal,et al.  Prospective double-blind randomized controlled study comparing heavy- and lightweight polypropylene mesh in totally extraperitoneal repair of inguinal hernia: early results , 2009, Surgical Endoscopy.

[27]  M. Hawn,et al.  Open suture versus mesh repair of primary incisional hernias: a cost–utility analysis , 2009, Hernia.

[28]  S. Bringman,et al.  Randomized clinical trial of groin hernia repair with titanium‐coated lightweight mesh compared with standard polypropylene mesh , 2008, The British journal of surgery.

[29]  U. Klinge Mesh for hernia repair , 2008, The British journal of surgery.

[30]  B. Ubrig,et al.  Sixty-month follow-up after endoscopic inguinal hernia repair with three types of mesh: a prospective randomized trial , 2008, Surgical Endoscopy.

[31]  G. Beets,et al.  Degradation of mesh coatings and intraperitoneal adhesion formation in an experimental model , 2009, The British journal of surgery.

[32]  S. Nixon,et al.  Recurrence after inguinal hernia repair at ten years by open darn, open mesh and TEP--no advantage with mesh. , 2009, The surgeon : journal of the Royal Colleges of Surgeons of Edinburgh and Ireland.