A selective single-phase-to-ground fault protection for neutral un-effectively grounded systems

Single-phase-to-ground faults are the most frequent faults likely to occur in power distribution networks. As for a neutral un-effectively grounded system (NUGS), the low fault current is very common in the case of occurrence of a single-phase earth fault, leading to hard identification of the faulty feeder. In conventional way, this target can be possibly achieved by the comparison of the polarities, magnitudes, or the phase angles of the zero-sequence currents of all feeders connected to the same busbar. However, it becomes a difficult task to implement this functionality into the protection of feeder. In this paper, a novel single-phase-to-ground fault protection for NUGS is put forward. Different from conventional centralized-comparison protection, this protection can detect single-phase-to-ground fault on the feeder individually, and can be realized on FTU (Feeder Terminal Unit). It is based on the measurement of the zero-sequence voltage and zero-sequence current. The tripping strategy follows the characteristic of the modified inverse-time delay curve. By means of analyzing the characteristics of the zero-sequence transient currents, it is disclosed that the magnitude of the zero-sequence current of the faulty feeder should be greater than that of any sound feeder. Then a composite compensated voltage is formed based on the zero-sequence voltage and zero-sequence current to evaluate a revising factor for every feeder respectively. Using this revising factor to modify the identical standard inverse-time delay curve adopted by all the feeder zero-sequence overvoltage protections, the tripping time of the zero-sequence overvoltage protections of all feeders will differ from each other. In this case, the selectivity of the protection can be guaranteed. This proposed algorithm is validated with the EMTP simulation tests.

[1]  Mao Peng WAVELETS PACKET BASED DETECTION OF PHASE-TO-GROUND FAULT IN DISTRIBUTION AUTOMATION SYSTEM , 2000 .

[2]  Gengyin Li,et al.  The similitude power detection on single-phase-to-ground fault in the non-solidly grounded system , 2005, 2005 IEEE/PES Transmission & Distribution Conference & Exposition: Asia and Pacific.

[3]  Fan Zhang,et al.  A new principle of fault line selection in non-solidly earthed network based on direction traveling wave , 2007, 2007 International Power Engineering Conference (IPEC 2007).

[4]  Li Fengxiang,et al.  A New Algorithm of Line Selection by Using Principle of Traveling Wave in Small Current Grounding Fault , 2010, 2010 International Conference on Electrical and Control Engineering.

[5]  Michel Meunier,et al.  Artificial neural networks for single phase fault detection in resonant grounded power distribution systems , 1996, Proceedings of 1996 Transmission and Distribution Conference and Exposition.

[6]  Yutian Liu,et al.  A method of fault line detection in distribution systems based on wavelets , 2002, Proceedings. International Conference on Power System Technology.

[7]  H. Roman,et al.  Earth-fault treatment in medium-voltage networks , 1997 .

[8]  Yang Yihan,et al.  Study on Fault Line Selection based on Transient and Mathematical Morphology in Resonant Grounded System , 2006, 2006 International Conference on Power System Technology.

[9]  Long Fei,et al.  Study on Line Selection of Grounded Fault in Non-effectively Earthed System Based on Wavelet Packet and Chaotic Neural Networks , 2009, 2009 Second International Conference on Intelligent Computation Technology and Automation.

[10]  Chunming Li,et al.  Simulation on Faulty Line Selection of Small Current Grounding System Based on Wavelet Transform , 2010, 2010 Asia-Pacific Power and Energy Engineering Conference.

[11]  Zhong-jian Kang,et al.  Study on the Non-power Frequency Transient Fault Selection in Distribution Network with a Single-Phase to Ground Fault Based on Hilbert-Huang Transform , 2010, 2010 International Conference on Electrical and Control Engineering.

[12]  Bingyin Xu,et al.  A new principle of faulty feeder detection for non-effectively earthed network using dominant transient frequency current , 2009, 2009 International Conference on Sustainable Power Generation and Supply.

[13]  Hongjiang He,et al.  The study of single line to ground fault line selection in non-direct ground power system based on DSP device , 2010, 2010 2nd International Conference on Advanced Computer Control.

[14]  Pierre Bertrand,et al.  Earth-fault detection in a compensated earthed network, without any voltage measurement: a new protection principle , 2001 .

[15]  Peiyu Wei,et al.  Study on single-phase earthed faulty feeder selection methods in non-solidly grounded systems , 2008, 2008 Third International Conference on Electric Utility Deregulation and Restructuring and Power Technologies.

[16]  Zhiqian Bo,et al.  A novel selective earth fault detection method using residual current , 2009, 2009 Transmission & Distribution Conference & Exposition: Asia and Pacific.

[17]  J.R. Saenz,et al.  Verifying resonant grounding in distribution systems , 2002, IEEE Computer Applications in Power.

[18]  Shu Hongchun,et al.  Research on Extension Method and Detection of Fault-Line Selection in Resonant Grounded Systems , 2008, 2008 Joint International Conference on Power System Technology and IEEE Power India Conference.

[19]  Yang Yihan,et al.  Multi-criteria relaying strategy for single phase to ground fault in MV power systems , 2002, Proceedings. International Conference on Power System Technology.