Capacitive position measurement for high-precision space inertial sensor

Low noise position measurement is fundamental for space inertial sensors, and at present the capacitive position sensor is widely employed for space inertial sensors. The design for the possible suppression of the front-end electric noises for a capacitive sensor is presented. A prototype capacitive sensor with 2×10−6pF/Hz1/2 at frequency above 0.04 Hz is achieved and further improvements are discussed.

[1]  T. Kataoka,et al.  Parallel resonance Q meter and its applications , 1994, Conference Proceedings. 10th Anniversary. IMTC/94. Advanced Technologies in I & M. 1994 IEEE Instrumentation and Measurement Technolgy Conference (Cat. No.94CH3424-9).

[2]  Aaas News,et al.  Book Reviews , 1893, Buffalo Medical and Surgical Journal.

[3]  John L. Crassidis,et al.  Sensors and actuators , 2005, Conference on Electron Devices, 2005 Spanish.

[4]  Bonny L. Schumaker,et al.  Disturbance reduction requirements for LISA , 2003 .

[5]  Rudy Lauwereins,et al.  Design, Automation, and Test in Europe , 2008 .

[6]  Robert L. Byer,et al.  Advanced gravitational reference sensor for high precision space interferometers , 2005 .

[7]  P. Touboul,et al.  Capacitive detection scheme for space accelerometers applications , 1999 .

[8]  Kenzo Watanabe,et al.  A Switched-Capacitor Digital Capacitance Bridge , 1984, IEEE Transactions on Instrumentation and Measurement.

[9]  Oskars Petersons,et al.  A Self-Balancing High-Voltage Capacitance Bridge , 1964 .

[10]  Pierre Touboul,et al.  Electrostatic space accelerometers for present and future missions 1 1 Based on paper IAF.96.J1.02 p , 1999 .

[11]  M. Peckerar,et al.  Low-Noise Signal Processing Chain for High Capacitance Sensors , 2008, IEEE Sensors Journal.

[12]  Srinivas Bettadpur,et al.  Precise accelerometry onboard the GRACE gravity field satellite mission , 2008 .

[13]  M. Bramanti A high sensitivity measuring technique for capacitive sensor transducers , 1990 .

[14]  Charles Birkbeck,et al.  Institution of Electrical Engineers , 2016, Nature.

[15]  Pierre Touboul,et al.  Flight experience on CHAMP and GRACE with ultra-sensitive accelerometers and return for LISA , 2003 .

[16]  R. Schilling,et al.  LISA and its in-flight test precursor SMART-2 , 2002 .

[17]  R. G. Green,et al.  A high frequency stray-immune capacitance transducer based on the charge transfer principle , 1988 .

[18]  Pak Kwong Chan,et al.  A Low-Power Switched-Capacitor Capacitive Transducer With High Resolution , 2008, IEEE Transactions on Instrumentation and Measurement.