A Noncontact Method for Locating Radial Artery above Radial Styloid Process in Thermal Image

A radial artery above the radial styloid process is called GUAN and is a critical position for collecting pulse wave in traditional Chinese medicine theory. Locating GUAN is a precondition for collecting radial pulse wave. However, existing methods for locating GUAN lead to large deviations. This paper proposes a novel nontouch method for locating GUAN based on thermal imaging and image processing. This method consists of three parts: the infrared thermal imaging location imaging platform, the wrist edge contour extraction algorithm based on arbitrary angle edge recognition, and radial protrusion recognition algorithm (x coordinate identification algorithm of GUAN) and radial artery fitting algorithm (y coordinate identification algorithm of GUAN). The infrared thermal imaging positioning imaging platform is used to ensure that the wrist of the subject enters the fixed imaging area in a fixed position during each measurement and transmits the thermal imaging images carrying the image information of radial processes and radial arteries to the upper computer. Arbitrary angle edge recognition algorithm is used to extract wrist contour and radial artery edge information. The x-axis coordinates of the radial artery were provided by the identification algorithm, and the y-axis coordinates of the radial artery were provided by the fitting algorithm. Finally, the x and y coordinates determine the GUAN position. The algorithm for locating GUAN could provide repeatable and reliable x and y coordinates. The proposed method shows that relative standard deviation (RSD) of x distance of GUAN is less than 9.0% and RSD of y distance of GUAN is less than 5.0%. The proposed method could provide valid GUAN coordinates and reduce deviations of locating GUAN.

[1]  Pasquale Arpaia,et al.  A piezo-film-based measurement system for global haemodynamic assessment , 2010, Physiological measurement.

[2]  David Zhang,et al.  A Novel Multichannel Wrist Pulse System With Different Sensor Arrays , 2015, IEEE Transactions on Instrumentation and Measurement.

[3]  K. Stamnes,et al.  The optics of human skin : Aspects important for human health , 2008 .

[4]  Jaeuk U. Kim,et al.  New Assessment Model of Pulse Depth Based on Sensor Displacement in Pulse Diagnostic Devices , 2013, Evidence-based complementary and alternative medicine : eCAM.

[5]  Nanyue Wang,et al.  Accurate cirrhosis identification with wrist-pulse data for mobile healthcare , 2012, mHealthSys '12.

[6]  Jun Zhang,et al.  An Edge Detection Method Based on Wavelet Transform at Arbitrary Angles , 2018, IEICE Trans. Inf. Syst..

[7]  Arthur de Sá Ferreira,et al.  Traditional Chinese medicine wrist pulse-taking is associated with pulse waveform analysis and hemodynamics in hypertension. , 2016, Journal of integrative medicine.

[8]  Ching-Hsing Luo,et al.  Non-invasive holistic health measurements using pulse diagnosis: II. Exploring TCM clinical holistic diagnosis using an ingestion test , 2016 .

[9]  Marc Garbey,et al.  Interacting with human physiology , 2007, Comput. Vis. Image Underst..

[10]  Yu-Feng Chung,et al.  Possibility of quantifying TCM finger-reading sensations: II. An example of health standardization , 2012 .

[11]  Young-Min Kim,et al.  Development of a Tonometric Sensor with a Decoupled Circular Array for Precisely Measuring Radial Artery Pulse , 2016, Sensors.

[12]  R. Sanders,et al.  External fixation of distal radial fractures: results and complications. , 1991, The Journal of hand surgery.

[13]  In Seon Lee,et al.  Pulse Wave Variation during the Menstrual Cycle in Women with Menstrual Pain , 2016, BioMed research international.

[14]  Ching-Hsing Luo,et al.  How to standardize the pulse-taking method of traditional Chinese medicine pulse diagnosis , 2013, Comput. Biol. Medicine.

[15]  David Zhang,et al.  A Compound Pressure Signal Acquisition System for Multichannel Wrist Pulse Signal Analysis , 2014, IEEE Transactions on Instrumentation and Measurement.

[16]  W P Cooney,et al.  Radial styloidectomy: a biomechanical study on stability of the wrist joint. , 2001, The Journal of hand surgery.

[17]  R. Anderson,et al.  The optics of human skin. , 1981, The Journal of investigative dermatology.

[18]  Wen-Miin Liang,et al.  A Novel Noninvasive Measurement Technique for Analyzing the Pressure Pulse Waveform of the Radial Artery , 2008, IEEE Transactions on Biomedical Engineering.

[19]  Yu-Feng Chung,et al.  Possibility of quantifying TCM finger-reading sensations: I. Bi-Sensing Pulse Diagnosis Instrument , 2012 .

[20]  Max Q.-H. Meng,et al.  Quantitative Analyses of Pulse Images in Traditional Chinese Medicine , 2008 .

[21]  J T Mehigan,et al.  Snuffbox arteriovenous fistula for hemodialysis. , 1982, American journal of surgery.

[22]  Yang Zhang,et al.  Self-Oscillating Fluxgate-Based Quasi-Digital Sensor for DC High-Current Measurement , 2015, IEEE Transactions on Instrumentation and Measurement.

[23]  Ching-Hsing Luo,et al.  Temporal and Spatial Properties of Arterial Pulsation Measurement Using Pressure Sensor Array , 2011, Evidence-based complementary and alternative medicine : eCAM.