Magnetic induction tomography: A brief review

Magnetic Induction Tomography (MIT) is a contactless non-invasive imaging technique that interested in mapping the passive electrical properties of a material; conductivity, permittivity and permeability. This paper presents the criteria and previous functional specification involving the development of MIT, focusing in conductivity imaging. Various ways have been implemented from a simple electronic configuration of the front-end sensory circuit, data acquisition system, reconstruction algorithm and graphical user interfacing (GUI) tools. Induction sensors are paramount as it does provide the signal source for time varying magnetic field to the coils. The advantages and limitations of MIT are also presented. Many more advancement can be expected to enhance the lack of MIT especially in spatial resolution and dynamic response of the sensor.

[1]  A Fast Reconstruction Method for Magnetic Induction Tomography , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[2]  Wuliang Yin,et al.  A planar EMT system for the detection of faults on thin metallic plates , 2006 .

[3]  Hans H. Gatzen,et al.  Eddy-current microsensor based on thin-film technology , 2002 .

[4]  M. Komorowski,et al.  A New Transducer for Magnetic Induction Tomography , 2009, IEEE Transactions on Magnetics.

[5]  Hermann Scharfetter,et al.  A new type of gradiometer for the receiving circuit of magnetic induction tomography (MIT). , 2005, Physiological measurement.

[6]  Hermann Scharfetter,et al.  Magnetic Induction Tomography: A feasibility study of brain oedema detection using a finite element human head model , 2007 .

[7]  Hermann Scharfetter,et al.  Biological tissue characterization by magnetic induction spectroscopy (MIS): requirements and limitations , 2003, IEEE Transactions on Biomedical Engineering.

[8]  H. Griffiths Magnetic induction tomography , 2001 .

[9]  S. Tumański Induction coil sensors—a review , 2007 .

[10]  D. C. Barber,et al.  Three-dimensional electrical impedance tomography , 1996, Nature.

[11]  Claudia Hannelore Igney,et al.  16 Channel Magnetic Induction Tomography System Featuring Parallel Readout , 2007 .

[12]  H. Lackner,et al.  Magnetic induction tomography: hardware for multi-frequency measurements in biological tissues. , 2001, Physiological measurement.

[13]  Anthony J. Peyton,et al.  Performance of a FPGA-based Direct Digitising Signal Measurement module for MIT , 2010 .

[14]  O. Dössel,et al.  Planar system for magnetic induction conductivity measurement using a sensor matrix. , 2004, Physiological measurement.

[15]  C Gabriel,et al.  The dielectric properties of biological tissues: I. Literature survey. , 1996, Physics in medicine and biology.

[16]  O Dössel,et al.  Design and performance of a planar-array MIT system with normal sensor alignment. , 2005, Physiological measurement.

[17]  M. S. Beck,et al.  Electromagnetic inductance tomography (EMT): sensor, electronics and image reconstruction algorithm for a system with a rotatable parallel excitation field , 1998 .

[18]  Marcin Ziolkowski,et al.  Weighted Sum Method and Genetic Algorithm Based Multiobjective Optimization of an Exciter for Magnetic Induction Tomography , 2009 .

[19]  M. Forsman,et al.  Intragastric movement assessment by measuring magnetic field decay of magnetised tracer particles in a solid meal , 2000, Medical and Biological Engineering and Computing.

[20]  H Scharfetter,et al.  Hardware for quasi-single-shot multifrequency magnetic induction tomography (MIT): the Graz Mk2 system. , 2008, Physiological measurement.

[21]  H Griffiths,et al.  Magnetic Induction Tomography: A Measuring System for Biological Tissues , 1999, Annals of the New York Academy of Sciences.

[22]  Khairi Mat Daud,et al.  Initial Results On Medium Frequency Electromagnetic Field Penetration In Biological Soft Tissue , 2011 .

[23]  Joaquim Ferreira,et al.  An overview of electromagnetic inductance tomography: Description of three different systems , 1996 .

[24]  Anthony J. Peyton,et al.  Development of Electromagnetic Tomography (EMT) for Industrial Applications. Part 1: Sensor Design and Instrumentation , 1999 .

[25]  Manuchehr Soleimani,et al.  Shape Reconstruction in Magnetic Induction Tomography Using Multifrequency Data , 2006 .

[26]  Sazali Yaacob,et al.  Advancements in Transmitters and Sensors for Biological Tissue Imaging in Magnetic Induction Tomography , 2012, Sensors.

[27]  Sazali Yaacob,et al.  Initial development on magnetic induction tomography imaging , 2011 .

[28]  Eddy Current Tomography for Metal Solidification Imaging , 1999 .

[29]  S. Crozier,et al.  Rotational magnetic induction tomography , 2012 .

[30]  Zheng Xu,et al.  The application of magnetic sensor in MIT , 2008, 2008 World Automation Congress.

[31]  H Griffiths,et al.  A highly phase-stable differential detector amplifier for magnetic induction tomography. , 2011, Physiological measurement.

[32]  Xuetao Shi,et al.  Preliminary imaging results of magnetic induction tomography based on physical phantom. , 2008, Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference.

[33]  H Scharfetter,et al.  Sensitivity maps and system requirements for magnetic induction tomography using a planar gradiometer. , 2001, Physiological measurement.

[34]  Manuchehr Soleimani,et al.  Hardware and software design for a National Instrument-based magnetic induction tomography system for prospective biomedical applications. , 2012, Physiological measurement.

[35]  Manuchehr Soleimani,et al.  A magnetic induction tomography system for prospective industrial processing applications , 2012 .

[36]  R. W. Lau,et al.  The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues. , 1996, Physics in medicine and biology.