Performance analysis of a modified trans-critical CO2 refrigeration cycle

Abstract Performance of a two-stage trans-critical CO2 refrigeration cycle, which contains internal heat exchanger, intercooler, ejector, and separator, has been analyzed after modification. Original cycle has been modified with extracting a line of saturated vapor flow from separator and feeding to the intercooler. The impacts of operational parameters such as gas cooler temperature, evaporator temperature, and gas cooler pressure, on the cycle performance have been investigated. Computed results showed that modified cycle improved the maximum coefficient of performance, COPmax, by 26.89% compared to the original cycle at a particular operation conditions. Meanwhile, this modification averagely decreased the exergy destruction rate by 18.6% compared to the original cycle.

[1]  J. Pettersen,et al.  A new, efficient and environmentally benign system for car air-conditioning , 1993 .

[2]  M. J. Moran,et al.  Thermal design and optimization , 1995 .

[3]  Jun Lan Yang,et al.  Performance investigation of transcritical carbon dioxide two-stage compression cycle with expander , 2007 .

[4]  Mortaza Yari,et al.  Performance analysis and optimization of a new two-stage ejector-expansion transcritical CO2 refrigeration cycle , 2009 .

[5]  Mortaza Yari,et al.  Cycle improvements to ejector‐expansion transcritical CO2 two‐stage refrigeration cycle , 2008 .

[6]  Mortaza Yari Exergetic analysis of the vapour compression refrigeration cycle using ejector as an expander , 2008 .

[7]  Alan A. Kornhauser,et al.  The Use of an Ejector as a Refrigerant Expander , 1990 .

[8]  Y. Çengel,et al.  Thermodynamics : An Engineering Approach , 1989 .

[9]  Jianlin Yu,et al.  Applying mechanical subcooling to ejector refrigeration cycle for improving the coefficient of performance , 2007 .

[10]  Eckhard A. Groll,et al.  Transcritical CO2 refrigeration cycle with ejector-expansion device , 2005 .

[11]  Shengming Liao,et al.  A correlation of optimal heat rejection pressures in transcritical carbon dioxide cycles , 2000 .

[12]  M Yari,et al.  Performance analysis of the ejector-vapour compression refrigeration cycle , 2007 .

[13]  Pei-Xue Jiang,et al.  Particular characteristics of transcritical CO2 refrigeration cycle with an ejector , 2007 .

[14]  Somchai Wongwises,et al.  Experimental investigation on the performance of the refrigeration cycle using a two-phase ejector as an expansion device , 2004 .

[15]  F. A. Manjili,et al.  Performance of a new two-stage multi-intercooling transcritical CO2 ejector refrigeration cycle , 2012 .