Classic linear models of fossil fired steam units have been used for decades in power system dynamic analyses. The effect of main steam pressure is often ignored or the more complex models of boiler and its control systems should be adopted in the simulations. Moreover, the variations of turbine enthalpy drop are not considered in those models, which may result in a great deviation of output power during a transient period after a disturbance. A new model with little increase in complexity is built in this paper to improve the accuracy of classic models, where the boiler effect and the enthalpy droop variations are considered by a simplified boiler model and replacements of three turbine model parameters. Test data of a 600-MW coal fired generation unit are adopted to compare the performance of the proposed model with that of a classic one. Higher accuracy of the new model are observed and it is proposed to replace the classic models in power system dynamic analyses.

[1]  Lin Gao,et al.  Simulation and optimization of load shedding scheme for islanded power system , 2010, 2010 International Conference on Power System Technology.

[2]  F. P. de Mello,et al.  Boiler models for system dynamic performance studies , 1991 .

[3]  B. Vahidi,et al.  Determining Parameters of Turbine's Model Using Heat Balance Data of Steam Power Unit for Educational Purposes , 2007, IEEE Transactions on Power Systems.

[4]  P. M. Anderson,et al.  A low-order system frequency response model , 1990 .

[5]  E. Cheres Small and medium size drum boiler models suitable for long term dynamic response , 1990 .

[6]  A. Stodola Steam and gas turbines , 1927 .

[7]  Ting Zhao,et al.  Research on the Primary Frequency Control Characteristics of Generators in Power System , 2007, 2007 2nd IEEE Conference on Industrial Electronics and Applications.

[8]  Mark O'Malley,et al.  A drum boiler model for long term power system dynamic simulation , 1999 .

[9]  T. Inoue,et al.  A model of fossil fueled plant with once-through boiler for power system frequency simulation studies , 2000 .

[10]  Lin Gao,et al.  A new framework for power system identification based on an improved genetic algorithm , 2009, 2009 4th IEEE Conference on Industrial Electronics and Applications.

[11]  Siemens Westinghouse Frequency Control Considerations for Modern Steam and Combustion Turbines , 1998 .

[12]  P. Kundur,et al.  DYNAMIC MODELS FOR FOSSIL FUELED STEAM UNITS IN POWER SYSTEM STUDIES Working Group on Prime Mover and Energy Supply Models for System Dynamic Performance Studies , 1991 .

[13]  Yiping Dai,et al.  Impact of Overspeed Protection Control on Stability for Islanded Power System , 2009 .

[14]  Ieee Report,et al.  Dynamic Models for Steam and Hydro Turbines in Power System Studies , 1973 .

[15]  Lin Gao,et al.  Analysis of power system frequency responses with hydro turbines incorporating load shedding , 2010, 2010 5th IEEE Conference on Industrial Electronics and Applications.

[16]  Lin Gao,et al.  Analysis of effects on primary frequency control and power grid stability of different control logic , 2010, 2010 5th IEEE Conference on Industrial Electronics and Applications.