Five years of sleep apnea treatment with a mandibular advancement device. Side effects and technical complications.

OBJECTIVE To determine the variation in prevalence of temporomandibular disorders (TMD), other side effects, and technical complications during 5 years of sleep apnea treatment with a mandibular advancement device. MATERIALS AND METHODS Forty patients diagnosed with obstructive sleep apnea received an adjustable appliance at 70% of the maximum protrusion. The protrusion was then progressively increased. TMD (diagnosed according to the Research Diagnostic Criteria for TMD), overjet, overbite, occlusal contacts, subjective side effects, and technical complications were recorded before and a mean of 14, 21, and 58 months after treatment and analyzed by the Wilcoxon test (P < .05). RESULTS Fifteen patients still used the oral appliance at the 5-year follow-up, and no significant variation in TMD prevalence was observed. Subjective side effects were common, and a significant reduction was found in overjet, overbite, and in the number of occlusal contacts. Furthermore, the patients made a mean of 2.5 unscheduled dental visits per year and a mean of 0.8 appliance repairs/relines per year by a dental technician. The most frequent unscheduled visits were needed during the first year and were a result of acrylic breakage on the lateral telescopic attachment, poor retention, and other adjustments to improve comfort. CONCLUSIONS Five-year oral appliance treatment does not affect TMD prevalence but is associated with permanent occlusal changes in most sleep apnea patients during the first 2 years. Patients seek several unscheduled visits, mainly because of technical complications.

[1]  J. Fleetham,et al.  Oral appliances for obstructive sleep apnoea. , 2006, The Cochrane database of systematic reviews.

[2]  M. Marklund Predictors of long-term orthodontic side effects from mandibular advancement devices in patients with snoring and obstructive sleep apnea. , 2006, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[3]  Å. Tegelberg,et al.  Influence on the masticatory system in treatment of obstructive sleep apnea and snoring with a mandibular protruding device: a 2-year follow-up. , 2004, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[4]  K. Franklin,et al.  Mandibular advancement device in patients with obstructive sleep apnea : long-term effects on apnea and sleep. , 2001, Chest.

[5]  S. Dworkin,et al.  Research diagnostic criteria for temporomandibular disorders: review, criteria, examinations and specifications, critique. , 1992, Journal of craniomandibular disorders : facial & oral pain.

[6]  D. Hillman,et al.  Dental side effects of an oral device to treat snoring and obstructive sleep apnea. , 1999, Sleep.

[7]  J. Martinez‐Gomis,et al.  Reproducibility of lateral excursive tooth contact in a semi-adjustable articulator depending on the type of lateral guidance. , 2005, Journal of oral rehabilitation.

[8]  E. Russi,et al.  Side effects of mandibular advancement devices for sleep apnea treatment. , 2001, American journal of respiratory and critical care medicine.

[9]  R. Ayuso-Montero,et al.  Influence of static and dynamic occlusal characteristics and muscle force on masticatory performance in dentate adults. , 2008, European journal of oral sciences.

[10]  A. Lowe,et al.  Long-term compliance and side effects of oral appliances used for the treatment of snoring and obstructive sleep apnea syndrome. , 2005, Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine.

[11]  J. Martinez‐Gomis,et al.  Relationship between chewing side preference and handedness and lateral asymmetry of peripheral factors. , 2009, Archives of oral biology.

[12]  G. Clark,et al.  Mandibular advancement devices and sleep disordered breathing. , 1998, Sleep medicine reviews.

[13]  U. Hägg,et al.  Long-term dentofacial changes in Chinese obstructive sleep apnea patients after treatment with a mandibular advancement device. , 2009, The Angle orthodontist.

[14]  Mary Farbood,et al.  Long-term sequellae of oral appliance therapy in obstructive sleep apnea patients: Part 2. Study-model analysis. , 2006, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[15]  A. Lowe,et al.  The effects of oral appliance therapy on occlusal function in patients with obstructive sleep apnea: a short-term prospective study. , 2007, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[16]  K. Franklin,et al.  Long‐term effects of mandibular repositioning appliances on symptoms of sleep apnoea , 2007, Journal of sleep research.

[17]  H. Ueda,et al.  Changes in occlusal contact area during oral appliance therapy assessed on study models. , 2008, The Angle orthodontist.

[18]  K. Ferguson,et al.  Oral appliances for snoring and obstructive sleep apnea: a review. , 2006, Sleep.

[19]  Daniel J Buysse,et al.  Sleep–Related Breathing Disorders in Adults: Recommendations for Syndrome Definition and Measurement Techniques in Clinical Research , 2000 .

[20]  P. Cistulli,et al.  A follow-up study of dental and skeletal changes associated with mandibular advancement splint use in obstructive sleep apnea. , 2007, American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics.

[21]  P. Cistulli,et al.  Treatment of snoring and obstructive sleep apnea with mandibular repositioning appliances. , 2004, Sleep medicine reviews.

[22]  I. Ringqvist,et al.  Effects and adverse events of a dental appliance for treatment of obstructive sleep apnoea. , 1999, Swedish dental journal.

[23]  Daniel J Buysse,et al.  Sleep-related breathing disorders in adults: recommendations for syndrome definition and measurement techniques in clinical research. The Report of an American Academy of Sleep Medicine Task Force. , 1999, Sleep.

[24]  L. Bondemark,et al.  Craniomandibular status and function in patients with habitual snoring and obstructive sleep apnoea after nocturnal treatment with a mandibular advancement splint: a 2-year follow-up. , 2000, European journal of orthodontics.

[25]  B. Kotecha,et al.  Evaluation of the Herbst Mandibular Advancement Splint in the management of patients with sleep-related breathing disorders. , 2000, Clinical otolaryngology and allied sciences.

[26]  David Watts Apnea , 1997, The Lancet.

[27]  S. Tufik,et al.  Effects of mandibular posture on obstructive sleep apnea severity and the temporomandibular joint in patients fitted with an oral appliance. , 2002, Sleep.

[28]  A. M. Strauss,et al.  Survey of oral appliance practice among dentists treating obstructive sleep apnea patients. , 1997, Chest.

[29]  I. Ringqvist,et al.  4-year follow-up of treatment with dental appliance or uvulopalatopharyngoplasty in patients with obstructive sleep apnea: a randomized study. , 2002, Chest.

[30]  B. Kotecha,et al.  Dental side‐effects of mandibular advancement splint wear in patients who snore , 2005, Clinical otolaryngology : official journal of ENT-UK ; official journal of Netherlands Society for Oto-Rhino-Laryngology & Cervico-Facial Surgery.