SimDoseCT: dose reporting software based on Monte Carlo simulation for a 320 detector-row cone-beam CT scanner and ICRP computational adult phantoms

This study aims to develop and test software for assessing and reporting doses for standard patients undergoing computed tomography (CT) examinations in a 320 detector-row cone-beam scanner. The software, called SimDoseCT, is based on the Monte Carlo (MC) simulation code, which was developed to calculate organ doses and effective doses in ICRP anthropomorphic adult reference computational phantoms for acquisitions with the Aquilion ONE CT scanner (Toshiba). MC simulation was validated by comparing CTDI measurements within standard CT dose phantoms with results from simulation under the same conditions. SimDoseCT consists of a graphical user interface connected to a MySQL database, which contains the look-up-tables that were generated with MC simulations for volumetric acquisitions at different scan positions along the phantom using any tube voltage, bow tie filter, focal spot and nine different beam widths. Two different methods were developed to estimate organ doses and effective doses from acquisitions using other available beam widths in the scanner. A correction factor was used to estimate doses in helical acquisitions. Hence, the user can select any available protocol in the Aquilion ONE scanner for a standard adult male or female and obtain the dose results through the software interface. Agreement within 9% between CTDI measurements and simulations allowed the validation of the MC program. Additionally, the algorithm for dose reporting in SimDoseCT was validated by comparing dose results from this tool with those obtained from MC simulations for three volumetric acquisitions (head, thorax and abdomen). The comparison was repeated using eight different collimations and also for another collimation in a helical abdomen examination. The results showed differences of 0.1 mSv or less for absolute dose in most organs and also in the effective dose calculation. The software provides a suitable tool for dose assessment in standard adult patients undergoing CT examinations in a 320 detector-row cone-beam scanner.

[1]  K. Ng,et al.  Comparison of computed tomography dose reporting software. , 2012, Radiation protection dosimetry.

[2]  Michael F McNitt-Gray,et al.  AAPM/RSNA Physics Tutorial for Residents: Topics in CT. Radiation dose in CT. , 2002, Radiographics : a review publication of the Radiological Society of North America, Inc.

[3]  B Bednarz,et al.  The development, validation and application of a multi-detector CT (MDCT) scanner model for assessing organ doses to the pregnant patient and the fetus using Monte Carlo simulations , 2009, Physics in medicine and biology.

[4]  T Hasegawa,et al.  Development of a web-based CT dose calculator: WAZA-ARI. , 2011, Radiation protection dosimetry.

[5]  D. Rogers,et al.  EGS4 code system , 1985 .

[6]  J J DeMarco,et al.  A Monte Carlo based method to estimate radiation dose from multidetector CT (MDCT): cylindrical and anthropomorphic phantoms. , 2005, Physics in medicine and biology.

[7]  Icrp ICRP Publication 103: Recommendations of the ICRP , 2013 .

[8]  M Wintermark,et al.  Radiation Dose-Reduction Strategies for Neuroradiology CT Protocols , 2007, American Journal of Neuroradiology.

[9]  I. Hernandez-Giron,et al.  Validation of a Monte Carlo simulation for dose assessment in dental cone beam CT examinations. , 2012, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[10]  W E Bolch,et al.  Voxel-based models representing the male and female ICRP reference adult--the skeleton. , 2007, Radiation protection dosimetry.

[11]  John M Boone,et al.  Reply to "Comment on the 'Report of AAPM TG 204: Size-specific dose estimates (SSDE) in pediatric and adult body CT examinations'" [AAPM Report 204, 2011]. , 2012, Medical physics.

[12]  I. Hernandez-Giron,et al.  A Monte Carlo simulation for the estimation of patient dose in rest and stress cardiac computed tomography with a 320-detector row CT scanner. , 2015, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[13]  K. P. Kim Development of Monte Carlo simulations to provide scanner-specific organ dose coefficients for contemporary CT , 2016 .

[14]  J J DeMarco,et al.  Estimating radiation doses from multidetector CT using Monte Carlo simulations: effects of different size voxelized patient models on magnitudes of organ and effective dose , 2007, Physics in medicine and biology.

[15]  Jacob Geleijns,et al.  Monte Carlo simulation of the dose distribution of ICRP adult reference computational phantoms for acquisitions with a 320 detector-row cone-beam CT scanner. , 2015, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[16]  Michiaki Kai,et al.  WAZA-ARI: computational dosimetry system for X-ray CT examinations. I. Radiation transport calculation for organ and tissue doses evaluation using JM phantom. , 2011, Radiation protection dosimetry.

[17]  Masanao Kobayashi,et al.  Dose Estimating Application Software Modification: Additional Function of a Size-Specific Effective Dose Calculator and Auto Exposure Control , 2017, Radiation protection dosimetry.

[18]  Jacob Geleijns,et al.  Overranging in multisection CT: quantification and relative contribution to dose--comparison of four 16-section CT scanners. , 2007, Radiology.

[19]  Willi A Kalender,et al.  Dose in x-ray computed tomography , 2014, Physics in medicine and biology.

[20]  O. Linton,et al.  NCRP REPORT NO. 160, IONIZING RADIATION EXPOSURE OF THE POPULATION OF THE UNITED STATES, MEDICAL EXPOSURE—ARE WE DOING LESS WITH MORE, AND IS THERE A ROLE FOR HEALTH PHYSICISTS? , 2009, Health physics.

[21]  F. Spiers,et al.  Photoelectron enhancement of the absorbed dose from X rays to human bone marrow: experimental and theoretical studies. , 1985, The British journal of radiology.

[22]  Yiming Gao,et al.  VirtualDose: a software for reporting organ doses from CT for adult and pediatric patients , 2015, Physics in medicine and biology.

[23]  Willi A. Kalender,et al.  Validation of a Monte Carlo tool for patient-specific dose simulations in multi-slice computed tomography , 2008, European Radiology.

[24]  Paul DeLuca,et al.  Realistic reference phantoms: An ICRP/ICRU joint effort , 2009, Annals of the ICRP.

[25]  G. Stamm,et al.  [CT-expo--a novel program for dose evaluation in CT]. , 2002, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin.

[26]  H. Nagel,et al.  CT-Expo - ein neuartiges Programm zur Dosisevaluierung in der CT , 2002 .

[27]  Akira Endo,et al.  WAZA-ARI: computational dosimetry system for X-ray CT examinations II: development of web-based system. , 2011, Radiation protection dosimetry.

[28]  J J Morant,et al.  Monte Carlo calculation of radiation dose in CT examinations using phantom and patient tomographic models. , 2005, Radiation protection dosimetry.

[29]  R. Joemai,et al.  Perfusion CT of the Brain and Liver and of Lung Tumors: Use of Monte Carlo Simulation for Patient Dose Estimation for Examinations With a Cone-Beam 320-MDCT Scanner. , 2016, AJR. American journal of roentgenology.

[30]  Young Hoon Roh,et al.  The Tendency of Medical Electrical Equipment - IEC 60601-2-54: Particular Requirements for the Basic Safety and Essential Performance of X-ray Equipment for Radiography and Radioscopy , 2015 .

[31]  Peter F Caracappa,et al.  Fetal doses to pregnant patients from CT with tube current modulation calculated using Monte Carlo simulations and realistic phantoms. , 2013, Radiation protection dosimetry.

[32]  C H McCollough,et al.  Performance evaluation of a multi-slice CT system. , 1999, Medical physics.

[33]  J J DeMarco,et al.  A Monte Carlo-based method to estimate radiation dose from spiral CT: from phantom testing to patient-specific models , 2003, Physics in medicine and biology.

[34]  B. Schmidt,et al.  A PC program for estimating organ dose and effective dose values in computed tomography , 1999, European Radiology.