Evaluating Innovative In-Ear Pulse Oximetry for Unobtrusive Cardiovascular and Pulmonary Monitoring During Sleep

Homecare is healthcare based on the principle “outpatient before inpatient,” with the aim of moving at least some care-delivery to the home. But reliable determination of vital signs at home requires new, smart sensors, which can be used by the patients themselves. We present a novel pulse oximetry sensor worn in the ear channel. It was previously shown that measurement of heart rate, arterial oxygen saturation and related respiratory information can be performed with reliable accuracy under laboratory conditions. The present study explores the clinical feasibility of the sensor system for cardiovascular monitoring during sleep, with the aim to diagnose sleep apnea. For this, human trials were performed in a sleep laboratory including patients with a clinical suspicion of sleep apnea. Besides a general analysis of the sensor's signal quality during sleep, the evaluation focuses on heart rate dynamics and time-variant oxygen saturation. In addition, several methods to derive respiration rate from photoplethysmographic signals are examined and discussed. Results from the in-ear sensor are compared with standard polysomnography monitoring and demonstrate that this novel system allows long-term nocturnal measurement of heart rate, oxygen saturation and respiratory rate with sufficient accuracy.

[1]  Hartmut Gehring,et al.  The effects of motion artifact and low perfusion on the performance of a new generation of pulse oximeters in volunteers undergoing hypoxemia. , 2002, Respiratory care.

[2]  F. Lemaire,et al.  Accuracy of pulse oximetry in the intensive care unit , 2001, Intensive Care Medicine.

[3]  Josef Högel,et al.  Decreased accuracy of pulse oximetry measurements during low perfusion caused by sepsis: is the perfusion index of any value? , 2006, Intensive Care Medicine.

[4]  Steffen Leonhardt,et al.  Advances in Reflective Oxygen Saturation Monitoring With a Novel In-Ear Sensor System: Results of a Human Hypoxia Study , 2012, IEEE Transactions on Biomedical Engineering.

[5]  Steffen Leonhardt,et al.  In-Ear SpO2 Monitoring with a Novel Optoelectronic Sensor for Long-Term Conditions , 2013 .

[6]  P. King,et al.  Design Of Pulse Oximeters , 1998, IEEE Engineering in Medicine and Biology Magazine.

[7]  Steffen Leonhardt,et al.  In-Ear Vital Signs Monitoring Using a Novel Microoptic Reflective Sensor , 2009, IEEE Transactions on Information Technology in Biomedicine.

[8]  J. Remmers,et al.  Characteristics of the snoring noise in patients with and without occlusive sleep apnea. , 1993, The American review of respiratory disease.

[9]  K. Arakawa,et al.  Pulse Oximetry and Circulatory Kinetics Associated with Pulse Volume Amplitude Measured by Photoelectric Plethysmography , 1986, Anesthesia and analgesia.

[10]  K. Matthes,et al.  Untersuchungen über die Sauerstoffsättigung des menschlichen Arterienblutes , 1935, Naunyn-Schmiedebergs Archiv für experimentelle Pathologie und Pharmakologie.

[11]  E. Chiner,et al.  Nocturnal oximetry for the diagnosis of the sleep apnoea hypopnoea syndrome: a method to reduce the number of polysomnographies? , 1999, Thorax.

[12]  A. Johansson Neural network for photoplethysmographic respiratory rate monitoring , 2003, Medical and Biological Engineering and Computing.

[13]  S. Leonhardt,et al.  A feasibility study evaluating innovative in-ear pulse oximetry for unobtrusive cardiovascular homecare monitoring during sleep , 2013, 2013 IEEE Point-of-Care Healthcare Technologies (PHT).

[14]  F. Yasuma,et al.  Respiratory sinus arrhythmia: why does the heartbeat synchronize with respiratory rhythm? , 2004, Chest.

[15]  T. Young,et al.  Estimation of the clinically diagnosed proportion of sleep apnea syndrome in middle-aged men and women. , 1997, Sleep.

[16]  A. B. Hertzman THE BLOOD SUPPLY OF VARIOUS SKIN AREAS AS ESTIMATED BY THE PHOTOELECTRIC PLETHYSMOGRAPH , 1938 .

[17]  J. Karemaker Counterpoint: respiratory sinus arrhythmia is due to the baroreflex mechanism. , 2009, Journal of applied physiology.