Feasibility of common carotid artery point of care ultrasound in cardiac output measurements compared to invasive methods

BackgroundCardiac output (CO) measurement in the intensive care unit (ICU) requires invasive devices such as the pulmonary artery (PA) catheter or arterial waveform pulse contour analysis (PCA). This study tests the accuracy and feasibility of point of care ultrasound (POCUS) of the common carotid artery to estimate the CO non-invasively and compare it to existing invasive CO measurement modalities.MethodsPatients admitted to the surgical and cardiothoracic ICU in a tertiary university-affiliated academic center during a 4-month period, with invasive hemodynamic monitoring devices for management, were included in this cohort study. Common carotid artery POCUS was performed to measure the CO and the results were compared to an invasive device.ResultsIntensivists and ICU fellows, using ultrasound of the common carotid artery, obtained the CO measurements. Images of the Doppler flow and volume were obtained at the level of the thyroid gland. Concurrent CO measured via invasive devices was recorded. The patient cohort comprised 36 patients; 52 % were females. The average age was 59 ± 13 years, and 66 % were monitored via PCA device and 33 % via PA catheter. Intraclass correlation coefficient (ICC) analysis demonstrated almost perfect correlation (0.8152) between measurements of CO via ultrasound vs. invasive modalities. The ICC between POCUS and the invasive measurement via PCA was 0.84 and via PA catheter 0.74, showing substantial agreement between the ultrasound and both invasive modalities.ConclusionsCommon carotid artery POCUS offers a non-invasive method of measuring the CO in the critically ill population.AbstractBackgroundLa misurazione della gittata cardiaca (CO) in Unità di Terapia Intensiva (ICU) richiede dispositivi invasivi come il cateterismo dell’arteria polmonare (PA) o l’analisi dell’onda dell’impulso arterioso (PCA). Questo studio si propone di valutare l’accuratezza e la fattibilità dell’ecografia (POCUS) della carotide comune per stimare la CO in modo non invasivo e confrontarla con le modalità esistenti di misurazione della CO effettuate in maniera invasiva.MetodiI pazienti ricoverati in terapia intensiva chirurgica e cardiotoracica in un centro accademico, affiliato con l’università, nel corso di un periodo di quattro mesi, sottoposti a dispositivi di monitoraggio emodinamico invasivo sono stati inclusi in questo studio. E’ stata eseguita l’ecografia dell’arteria carotide comune per misurare la CO ed i risultati sono stati confrontati con una tecnica invasiva.RisultatiMedici di terapia intensiva e borsisti, utilizzando l’ecografia della carotide comune, hanno ottenuto le misurazioni della CO. Immagini del flusso Doppler e di volume sono state ottenute a livello della ghiandola tiroidea. Contemporaneamente è è stata registrata la CO mediante dispositivi invasivi. Il gruppo era costituito da 36 pazienti; Il 52 % erano femmine. L’età media era di 59 ± 13 anni, e il 66 % sono stati monitorati tramite dispositivo PCA e il 33 % tramite catetere PA. L’analisi del coefficiente di correlazione (ICC) ha dimostrato la correlazione quasi perfetta (0,8152) tra le misurazioni della CO con gli ultrasuoni e quelle con modalità invasive. Il ICC tra POCUS e la misurazione invasiva tramite PCA era 0,84 e catetere della PA era 0,74 mostrando sostanziale accordo tra l’ecografia e entrambe le modalità invasive.ConclusioniLa POCUS dell’arteria carotide comune offre un metodo non invasivo per misurare la CO nel paziente critico.

[1]  H. Gershengorn,et al.  Understanding Changes in Established Practice: Pulmonary Artery Catheter Use in Critically III Patients* , 2013, Critical care medicine.

[2]  C. Moore,et al.  Point-of-care ultrasonography. , 2011, The New England journal of medicine.

[3]  F. Krummenauer,et al.  Lack of association between carotid artery volume blood flow and cardiac output. , 2001, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[4]  Michael K Gould,et al.  Preventing complications of central venous catheterization. , 2003, The New England journal of medicine.

[5]  A. Bassily-Marcus,et al.  Effect of lower limb compression devices on thermodilution cardiac output measurement* , 2007, Critical care medicine.

[6]  S. Langlois Focused ultrasound training for clinicians , 2007, Critical care medicine.

[7]  T. Keller,et al.  Modification of focal cerebral ischemia by cardiac output augmentation. , 1985, The Journal of surgical research.

[8]  D. Young,et al.  Pulmonary artery catheters for adult patients in intensive care. , 2013, The Cochrane database of systematic reviews.

[9]  P. Cooperberg,et al.  Sonographic examination of the carotid arteries. , 2005, Radiographics : a review publication of the Radiological Society of North America, Inc.

[10]  Shigehiko Ogoh,et al.  The distribution of blood flow in the carotid and vertebral arteries during dynamic exercise in humans , 2011, The Journal of physiology.

[11]  S. Kempley,et al.  Blood flow in the common carotid artery in term and preterm infants: reproducibility and relation to cardiac output , 2005, Archives of Disease in Childhood - Fetal and Neonatal Edition.

[12]  جمال الهاشمي,et al.  Cardiac output monitoring: an integrative perspective , 2011 .

[13]  B. Walder,et al.  Complications of central venous catheters: Internal jugular versus subclavian access—A systematic review , 2002, Critical care medicine.

[14]  S. Uematsu,et al.  Measurement of carotid blood flow in man and its clinical application. , 1983, Stroke.

[15]  T. Keller,et al.  Loss of cerebral regulation during cardiac output variations in focal cerebral ischemia. , 1992, Journal of neurosurgery.