VARIABLE-FREQUENCY PRONY METHOD IN THE ANALYSIS OF ELECTRICAL POWER QUALITY

The article presents a new modification of the the least squares Prony method. The so-called variable-frequency Prony method can be a useful tool for estimating parameters of sinusoidal components, which, in the analyzed signal , are characterized by time-dependent frequencies. The authors propose use of the presented method for testing the quality of electric energy. It allows observation of phenomena which, when using traditional methods, are averaged in the analysis window. The pr oposed modification of least squares Prony method is based on introd uction and specific selection of a frequency matrix. This matrix represents frequencies of estimated components and their variability in time.

[1]  J. Mroczka,et al.  A Reduced Prony's Method in Power-Quality Analysis—Parameters Selection , 2010, IEEE Transactions on Power Delivery.

[2]  Tadeusz Lobos,et al.  High-resolution spectrum-estimation methods for signal analysis in power systems , 2006, IEEE Transactions on Instrumentation and Measurement.

[3]  Zbigniew Leonowicz,et al.  Parametric methods for time-frequency analysis of electric signals , 2006 .

[4]  Józef Borkowski,et al.  CONTINUOUS AND DISCONTINUOUS LINEAR APPROXIMATION OF THE WINDOW SPECTRUM BY LEAST SQUARES METHOD , 2011 .

[5]  C. K. Yuen,et al.  Digital spectral analysis , 1979 .

[6]  E.A. Feilat Prony analysis technique for estimation of the mean curve of lightning impulses , 2006, IEEE Transactions on Power Delivery.

[7]  Janusz Mroczka,et al.  Short Time Algorithm of Power Waveforms Fundamental Harmonic Estimation With Use of Prony's Methods , 2011 .

[8]  E. Feilat,et al.  Detection of voltage envelope using Prony analysis-Hilbert transform method , 2006, IEEE Transactions on Power Delivery.

[9]  Soon-Ryul Nam,et al.  An Analytic Method for Measuring Accurate Fundamental Frequency Components , 2002 .

[10]  H Markiewicz,et al.  Voltage Disturbances Standard EN 50160 - Voltage Characteristics in Public Distribution Systems , 2008 .

[11]  Tapan K. Sarkar,et al.  Comparison between the Matrix Pencil Method and the Fourier Transform Technique for High-Resolution Spectral Estimation , 1996, Digit. Signal Process..

[12]  Xiang-Gen Xia,et al.  Discrete chirp-Fourier transform and its application to chirp rate estimation , 2000, IEEE Trans. Signal Process..

[13]  Jozef Borkowski,et al.  LIDFT method with classic data windows and zero padding in multifrequency signal analysis , 2010 .

[14]  Liu Xian-cheng,et al.  IEC 61000-4-30:Introduction of 2008 Version Standard of EMC-Experiment and Measurement Technology-Methods of Power Quality Measurement , 2010 .

[15]  Xu Peiliang,et al.  Overview of Total Least Squares Methods , 2013 .

[16]  Klaus Röbenack,et al.  On generalized inverses of singular matrix pencils , 2011, Int. J. Appl. Math. Comput. Sci..

[17]  J. Mroczka,et al.  Data compression using Prony's method and wavelet transform in power quality monitoring systems , 2006 .