Regioisomeric analysis of triacylglycerols using silver-ion liquid chromatography-atmospheric pressure chemical ionization mass spectrometry: comparison of five different mass analyzers.

Silver-ion high-performance liquid chromatography (HPLC) coupled to atmospheric pressure chemical ionization mass spectrometry (APCI-MS) is used for the regioisomeric analysis of triacylglycerols (TGs). Standard mixtures of TG regioisomers are prepared by the randomization reaction from 8 mono-acid TG standards (tripalmitin, tristearin, triarachidin, triolein, trielaidin, trilinolein, trilinolenin and tri-gamma-linolenin). In total, 32 different regioisomeric doublets and 11 triplets are synthesized, separated by silver-ion HPLC using three serial coupled chromatographic columns giving a total length of 75cm. The retention of TGs increases strongly with the double bond (DB) number and slightly for regioisomers having more DBs in sn-1/3 positions. DB positional isomers (linolenic vs. γ-linolenic acids) are also separated and their reverse retention order in two different mobile phases is demonstrated. APCI mass spectra of all separated regioisomers are measured on five different mass spectrometers: single quadrupole LC/MSD (Agilent Technologies), triple quadrupole API 3000 (AB SCIEX), ion trap Esquire 3000 (Bruker Daltonics), quadrupole time-of-flight micrOTOF-Q (Bruker Daltonics) and LTQ Orbitrap XL (Thermo Fisher Scientific). The effect of different types of mass analyzer on the ratio of [M+H-R(i)COOH](+) fragment ions in APCI mass spectra is lower compared to the effect of the number of DBs, their position on the acyl chain and the regiospecific distribution of acyl chains on the glycerol skeleton. Presented data on [M+H-R(i)COOH](+) ratios measured on five different mass analyzers can be used for the direct regioisomeric determination in natural and biological samples.

[1]  R. Evershed,et al.  Identification of triacylglycerol positional isomers present in vegetable oils by high performance liquid chromatography/atmospheric pressure chemical ionization mass spectrometry , 1997 .

[2]  C. Akoh,et al.  Food Lipids: Chemistry, Nutrition, and Biotechnology , 1998 .

[3]  P. Sandra,et al.  Considerations on comprehensive and off-line supercritical fluid chromatography x reversed-phase liquid chromatography for the analysis of triacylglycerols in fish oil. , 2010, Journal of separation science.

[4]  I. Valterová,et al.  Analysis of triacylglycerols in fat body of bumblebees by chromatographic methods. , 2006, Journal of chromatography. A.

[5]  Samir Julka,et al.  Instability of hexane-acetonitrile mobile phases used for the chromatographic analysis of triacylglycerides. , 2008, Journal of separation science.

[6]  J. Melanson,et al.  Quantitative analysis of positional isomers of triacylglycerols via electrospray ionization tandem mass spectrometry of sodiated adducts. , 2010, Rapid communications in mass spectrometry : RCM.

[7]  B. Nikolova-Damyanova Retention of lipids in silver ion high-performance liquid chromatography: facts and assumptions. , 2009, Journal of chromatography. A.

[8]  W. Byrdwell,et al.  Atmospheric pressure chemical ionization mass spectrometry for analysis of lipids , 2001, Lipids.

[9]  H. Sovová,et al.  Comparison of various types of stationary phases in non-aqueous reversed-phase high-performance liquid chromatography-mass spectrometry of glycerolipids in blackcurrant oil and its enzymatic hydrolysis mixture. , 2009, Journal of chromatography. A.

[10]  W. Christie,et al.  Silver ion high-performance liquid chromatography of derivatives of isomeric fatty acids , 1992 .

[11]  T. V. van Beek,et al.  Comprehensive two-dimensional liquid chromatography with ultraviolet, evaporative light scattering and mass spectrometric detection of triacylglycerols in corn oil. , 2008, Journal of chromatography. A.

[12]  G. Duchateau,et al.  Silver-phase high-performance liquid chromatography–electrospray mass spectrometry of triacylglycerols , 1998 .

[13]  M. Holčapek,et al.  Quantitation of triacylglycerols in plant oils using HPLC with APCI-MS, evaporative light-scattering, and UV detection. , 2005, Journal of separation science.

[14]  W. Byrdwell The bottom-up solution to the triacylglycerol lipidome using atmospheric pressure chemical ionization mass spectrometry , 2005, Lipids.

[15]  L. Fay,et al.  Quantitative analysis of triacylglycerol regioisomers in fats and oils using reversed-phase high-performance liquid chromatography and atmospheric pressure chemical ionization mass spectrometry. , 2004, Rapid communications in mass spectrometry : RCM.

[16]  D. Axelson,et al.  Differentiation of Fish Oils According to Species by 13C-NMR Regiospecific Analyses of Triacyglycerols , 2009 .

[17]  E. Forgács,et al.  Quantification of the ratio of positional isomer dilinoleoyl-oleoyl glycerols in vegetable oils. , 2003, Rapid communications in mass spectrometry : RCM.

[18]  R. Evershed,et al.  Structure analysis of triacylglycerol positional isomers using atmospheric pressure chemical ionisation mass spectrometry , 1996 .

[19]  M. Holčapek,et al.  Quantitation of triacylglycerols from plant oils using charged aerosol detection with gradient compensation. , 2007, Journal of chromatography. A.

[20]  M. Holčapek,et al.  Analytical monitoring of the production of biodiesel by high-performance liquid chromatography with various detection methods. , 1999, Journal of chromatography. A.

[21]  L. Mondello,et al.  Off-line coupling of non-aqueous reversed-phase and silver ion high-performance liquid chromatography-mass spectrometry for the characterization of rice oil triacylglycerol positional isomers. , 2004, Journal of chromatography. A.

[22]  M. Bohác,et al.  Statistical evaluation of triacylglycerol composition in plant oils based on high-performance liquid chromatography-atmospheric pressure chemical ionization mass spectrometry data. , 2009, Journal of agricultural and food chemistry.

[23]  L. Mondello,et al.  Determination of beef tallow in lard through a multidimensional off-line non-aqueous reversed phase-argentation LC method coupled to mass spectrometry. , 2006, Journal of separation science.

[24]  Michal Holcapek,et al.  Regioisomeric characterization of triacylglycerols using silver-ion HPLC/MS and randomization synthesis of standards. , 2009, Analytical chemistry.

[25]  G. Just,et al.  C-nucleosides and related compounds X synthesis of the carbocyclic analogues of D, L-pyrazofurin a (pyrazomycin) and showdomycin , 1976 .

[26]  W. Neff,et al.  Dual parallel electrospray ionization and atmospheric pressure chemical ionization mass spectrometry (MS), MS/MS and MS/MS/MS for the analysis of triacylglycerols and triacylglycerol oxidation products. , 2002, Rapid communications in mass spectrometry : RCM.

[27]  W. Christie Separation of molecular species of triacylglycerols by high-performance liquid chromatography with a silver ion column. , 1988, Journal of chromatography.

[28]  G. Allmaier,et al.  The renaissance of high-energy CID for structural elucidation of complex lipids: MALDI-TOF/RTOF-MS of alkali cationized triacylglycerols , 2009, Journal of the American Society for Mass Spectrometry.

[29]  Xingwen Li,et al.  Examining the collision-induced decomposition spectra of ammoniated triglycerides as a function of fatty acid chain length and degree of unsaturation. II. The PXP/YPY series. , 2005, Rapid communications in mass spectrometry : RCM.

[30]  A. Kuksis,et al.  Regioselective separation of isomeric triacylglycerols by reversed-phase high-performance liquid chromatography: stationary phase and mobile phase effects. , 2006, Journal of separation science.

[31]  M. Malone,et al.  Determining the relative amounts of positional isomers in complex mixtures of triglycerides using reversed-phase high-performance liquid chromatography-tandem mass spectrometry , 2004, Lipids.

[32]  W. Christie,et al.  Silver ion chromatography of lipids and fatty acids. , 1995, Journal of chromatography. B, Biomedical applications.

[33]  M. Holčapek,et al.  Orthogonality of silver-ion and non-aqueous reversed-phase HPLC/MS in the analysis of complex natural mixtures of triacylglycerols. , 2009, Journal of separation science.

[34]  Michal Holcapek,et al.  Triacylglycerols profiling in plant oils important in food industry, dietetics and cosmetics using high-performance liquid chromatography-atmospheric pressure chemical ionization mass spectrometry. , 2008, Journal of chromatography. A.

[35]  M. Holčapek,et al.  Characterization of triacylglycerol and diacylglycerol composition of plant oils using high-performance liquid chromatography-atmospheric pressure chemical ionization mass spectrometry. , 2003, Journal of chromatography. A.

[36]  Xingwen Li,et al.  Examining the collision-induced decomposition spectra of ammoniated triglycerides. III. The linoleate and arachidonate series. , 2007, Rapid communications in mass spectrometry : RCM.

[37]  P. Voutilainen,et al.  Analysis of triacylglycerols by silver-ion high-performance liquid chromatography-atmospheric pressure chemical ionization mass spectrometry , 1996, Lipids.

[38]  H. Janssen,et al.  An improved method for sn-2 position analysis of triacylglycerols in edible oils and fats based on immobilised lipase D (Rhizopus delemar). , 2006, Journal of chromatography. A.

[39]  H. Kallio,et al.  Quantification of triacylglycerol regioisomers in oils and fat using different mass spectrometric and liquid chromatographic methods. , 2007, Rapid communications in mass spectrometry : RCM.

[40]  R. Adlof Analysis of triacylglycerol positional isomers by silver ion high performance liquid chromatography , 1995 .

[41]  M. Holčapek,et al.  High-performance liquid chromatography-atmospheric pressure chemical ionization mass spectrometry and gas chromatography-flame ionization detection characterization of Delta5-polyenoic fatty acids in triacylglycerols from conifer seed oils. , 2007, Journal of chromatography. A.

[42]  M. Barber,et al.  The mass spectrometry of large molecules I. The triglycerides of straight chain fatty acids. , 1964 .

[43]  A. Tchapla,et al.  Regioisomer characterization of triacylglycerols by non-aqueous reversed-phase liquid chromatography/electrospray ionization mass spectrometry using silver nitrate as a postcolumn reagent. , 2010, Journal of mass spectrometry : JMS.

[44]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.