Jet penetration measurements in a venturi scrubber
暂无分享,去创建一个
The maximum centreline penetrations, l**, of cross-current liquid jets in a Venturi scrubber were measured for orifice diameters, d, of 1.397, 2.108, 2.565 and 3.860 mm. The data are correlated by
for the range of conditions, 36 ≤ gas throat velocity Vg ≤ 125 m/s; 1.2 ≤ liquid injection velocity Vj ≤ 18 m/s;
0.06 ≤ liquid to gas ratio
On a mesure la penetration maximale sur l'axe central, de jets liquides en ecoulement transversal dans un epurateur Venturi, pour des diametres d'orifices de 1.397, 2.108, 2.565 et 3.860 mm. On a etabli une correlation entre les resultats obtenus au moyen de l'equation:
dans les limites des conditions suivantes: 36 ≤ la vitesse du gaz a la gorge de l'epurateur Vg ≤ 125 m/sec.
0.06 ≤ liquid to gas ratio
[1] D. B. Roberts,et al. ATOMIZATION IN A VENTURI SCRUBBER , 1981 .
[2] Joseph A. Schetz,et al. Penetration and Breakup of Liquids in Subsonic Airstreams , 1977 .
[3] R. H. Boll. Particle Collection and Pressure Drop in Venturi Scrubbers , 1973 .
[4] M. Adelberg. Breakup rate and penetration of a liquid jet in a gas stream. , 1967 .