Refractive effects in coherent anti-Stokes Raman scattering microscopy.

Coherent anti-Stokes Raman scattering (CARS) microscopy with high sensitivity and high three- dimensional resolution has been developed for the vibrational imaging of chemical species. Due to the coherent nature of the CARS emission, it has been reported that the detection of epi-CARS and forward-CARS (F-CARS) signals depends on the size and shape of the sample. We investigate theoretically and experimentally the effects on the CARS signal of refractive index mismatches between the sample and its surroundings. Backward-CARS and F-CARS signals are measured for different polystyrene bead diameters embedded in different refractive index solvents. We show that index mismatches result in a backward-reflected F-CARS signal that generally dominates the experimentally backward-detected signal. Simulations based on geometrical and wave optics comparing forward- and backward-detected signals for polystyrene beads embedded in different index solvents confirm our findings. Furthermore, we demonstrate that the maxima of forward- and backward-detected signals are generated at different positions along the optical axis in the sample if refractive index mismatches are present between the sample and its surroundings.

[1]  Pekka Hänninen,et al.  Refractive‐index‐induced aberrations in two‐photon confocal fluorescence microscopy , 1994 .

[2]  S. Hell,et al.  Aberrations in confocal fluorescence microscopy induced by mismatches in refractive index , 1993 .

[3]  Haim Lotem,et al.  Interference between Raman resonances in four-wave difference mixing , 1976 .

[4]  W. R. Wiley,et al.  Three-Dimensional Vibrational Imaging by Coherent Anti-Stokes Raman Scattering , 1999 .

[5]  A. Diaspro,et al.  Influence of refractive-index mismatch in high-resolution three-dimensional confocal microscopy. , 2002, Applied optics.

[6]  G. Bjorklund,et al.  Effects of focusing on third-order nonlinear processes in isotropic media. [laser beam interactions , 1975 .

[7]  G. J. Brakenhoff,et al.  Refractive index and axial distance measurements in 3-D microscopy , 1992 .

[8]  T. Visser,et al.  Volume measurements in three-dimensional microscopy , 2008 .

[9]  A. Hall Applied Optics. , 2022, Science.

[10]  Andreas Volkmer,et al.  Vibrational Imaging with High Sensitivity via Epidetected Coherent Anti-Stokes Raman Scattering Microscopy , 2001 .

[11]  Eric O. Potma,et al.  Nonlinear coherent four-wave mixing in optical microscopy , 2000 .

[12]  Andreas Volkmer,et al.  Vibrational imaging and microspectroscopies based on coherent anti-Stokes Raman scattering microscopy , 2005 .

[13]  H T van der Voort,et al.  Imaging properties in two-photon excitation microscopy and effects of refractive-index mismatch in thick specimens. , 1999, Applied optics.

[14]  Jun Ye,et al.  High-sensitivity coherent anti-Stokes Raman scattering microscopy with two tightly synchronized picosecond lasers. , 2002, Optics letters.

[15]  Andreas Volkmer,et al.  Theoretical and experimental characterization of coherent anti-Stokes Raman scattering microscopy , 2002 .

[16]  W. Decraemer,et al.  A procedure to determine the correct thickness of an object with confocal microscopy in case of refractive index mismatch , 2005, Journal of microscopy.

[17]  X. Xie,et al.  Coherent Anti-Stokes Raman Scattering Microscopy: Instrumentation, Theory, and Applications , 2004 .